Names: optixRtnIFPortCfgLinkID
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRtnIFPortCfgLinkID",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the current radio link ID. As an identifier of a radio link, this parameter is used to prevent incorrect connections of radio links between sites. Value range: 1 to 4094\"",
"DEFVAL",
"{",
"1",
"}",
"::=",
"{",
"optixRtnIFPortGeneralAttribEntry",
"1",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the current radio link ID. As an identifier of a radio link, this parameter is used to prevent incorrect connections of radio links between sites. Value range: 1 to 4094"
],
null,
null,
null,
[
"DEFVAL",
1
]
]
}
- Huawei MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Huawei support.
Module: OPTIX-RTN-IFBOARD-ATTRIB-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['optixRtnOduIndex1', 'optixRtnOduIndex2'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4']}