Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwXdslAttndrMethod",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"attndrMethod0",
"(",
"0",
")",
",",
"attndrMethod1",
"(",
"1",
")",
",",
"attndrMethod2",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This parameter specifies the method to be used for the calculation of the ATTNDR in the downstream and upstream direction. The parameter can take three values 0, 1 and 2. Default values: attndrMethod1. Options: 1. attndrMethod0(0) - The basic Attainable Net Data Rate method 2. attndrMethod1(1) - The improved Attainable Net Data Rate method, If the control parameter attndr_method is set to a value of 1, the VTU-O and VTU-R shall use the impulse noise protection limit INP_min0 with value as indicated in O-TPS. If O-TPS configures for dual bearer channel mode, then the highest INP_MINn over the bearer channels shall be used 1 3. attndrMethod2(2) - The improved Attainable Net Data Rate method, If the control parameter attndr_method is set to a value of 2, the VTU-O and VTU-R shall use an impulse noise protection limit INP_MIN0 = 0 Note: When hwXdslAttndrStandardMethod set to no, the VTU-O will use a vendor discretionary algorithm to optimize the ATTNDR. \"",
"REFERENCE",
"\"ITU-T G.993.2, paragraph 11.4.1.1.7\"",
"::=",
"{",
"hwXdslAttndrConfig",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"attndrMethod0",
0
],
[
"attndrMethod1",
1
],
[
"attndrMethod2",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This parameter specifies the method to be used for the calculation of the ATTNDR in the downstream and upstream direction. The parameter can take three values 0, 1 and 2. Default values: attndrMethod1. Options: 1. attndrMethod0(0) - The basic Attainable Net Data Rate method 2. attndrMethod1(1) - The improved Attainable Net Data Rate method, If the control parameter attndr_method is set to a value of 1, the VTU-O and VTU-R shall use the impulse noise protection limit INP_min0 with value as indicated in O-TPS. If O-TPS configures for dual bearer channel mode, then the highest INP_MINn over the bearer channels shall be used 1 3. attndrMethod2(2) - The improved Attainable Net Data Rate method, If the control parameter attndr_method is set to a value of 2, the VTU-O and VTU-R shall use an impulse noise protection limit INP_MIN0 = 0 Note: When hwXdslAttndrStandardMethod set to no, the VTU-O will use a vendor discretionary algorithm to optimize the ATTNDR."
],
[
"REFERENCE",
"ITU-T G.993.2, paragraph 11.4.1.1.7"
],
null,
null,
null
]
}