Name identifying Transfer configuration
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.2011.6.157.4.1.1
Name identifying Transfer configuration
Identification
{1 3 6 1 4 1 2011 6 157 4 1 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
hwEnergyFtpcTransFileEntry OBJECT-TYPE
SYNTAX HwEnergyFtpcTransFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name identifying Transfer configuration"
INDEX { hwEnergyFtpcSetName }
::= { hwEnergyFtpcTransFileTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Name identifying Transfer configuration
Huawei MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: hwEnergyFtpcTransFileEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwEnergyFtpcTransFileEntry",
"OBJECT-TYPE",
"SYNTAX",
"HwEnergyFtpcTransFileEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Name identifying Transfer configuration\"",
"INDEX",
"{",
"hwEnergyFtpcSetName",
"}",
"::=",
"{",
"hwEnergyFtpcTransFileTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"HwEnergyFtpcTransFileEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Name identifying Transfer configuration"
],
null,
null,
[
"INDEX",
[
[
0,
"hwEnergyFtpcSetName"
]
]
],
null
]
}Vendor MIB copy from the LibreNMS archive. Huawei support.
Module: HUAWEI-ENERGYMNGT-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'DateAndTime', 'TruthValue', 'RowStatus'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['IpAddress', 'Integer32', 'Counter64', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Same file in Observium Community.
Vendor MIB copy from the Netdisco archive.
Module: HUAWEI-ENERGYMNGT-MIB
{'SNMPv2-TC': ['DisplayString', 'DateAndTime', 'TruthValue', 'RowStatus'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['IpAddress', 'Integer32', 'Counter64', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.157.4.1.1.1 | hwEnergyFtpcSetName | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.2 | hwEnergyFtpcSrcAddrType | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.3 | hwEnergyFtpcSrcAddr | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.4 | hwEnergyFtpcVpnName | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.5 | hwEnergyFtpcHostAddrType | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.6 | hwEnergyFtpcHostAddr | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.7 | hwEnergyFtpcServerPort | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.8 | hwEnergyFtpcUserName | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.9 | hwEnergyFtpcPassword | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.10 | hwEnergyFtpcDirectory | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.11 | hwEnergyFtpcSrcIfName | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.12 | hwEnergyFtpcTransCfgRowStatus | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.13 | hwEnergyFtpcAction | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.14 | hwEnergyFtpcTransMode | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.157.4.1.1.15 | hwEnergyFtpOperStatus | 0 | 0 |