DC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.5
DC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
Identification
{1 3 6 1 4 1 2011 6 164 1 3 2 2 1 5}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In EMAP-MIB, the row index hwRectOperIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.5.<hwRectOperIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
hwRectDCOutputPower OBJECT-TYPE
SYNTAX Unsigned32 (0..30000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC output power.
Value range: 0 to 30000,
units: W,
and the value is an integer.(1).
If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid."
::= { hwRectOperEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
DC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: hwRectDCOutputPower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwRectDCOutputPower",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"30000",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"DC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.\"",
"::=",
"{",
"hwRectOperEntry",
"5",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
30000
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"DC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: EMAP-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.1 | hwRectOperIndex | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.2 | hwRectOutputCurrent | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.3 | hwRectOutputVoltage | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.4 | hwRectTotalOperTime | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.6 | hwRectACVoltage | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.7 | hwRectRatedEfficiency | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.8 | hwRectifierTemperature | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.99 | hwRectOperStatus | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.100 | hwRectOperRowStatus | 0 | 0 |