OID reference

hwBattStringOperStatus

1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99

Description

State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indica…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.2011.6.164.1.4.4.2.1 (hwBattStringOperEntry)
Node code
99
Node name
hwBattStringOperStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99
URN notation
urn:oid:1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 2011 6 164 1 4 4 2 1 99}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteBatterys(4) hwBattString(4) hwBattStringOperTable(2) hwBattStringOperEntry(1) hwBattStringOperStatus(99)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/2011/6/164/1/4/4/2/1/99
  • /ISO/Identified-Organization/6/1/4/1/2011/6/164/1/4/4/2/1/99
  • /ISO/3/6/1/4/1/2011/6/164/1/4/4/2/1/99
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/enterprises/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/enterprises/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/enterprises/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/enterprises/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/ldap-enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/ldap-enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/vendor-objects/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • /iso/org/dod/internet/private/vendor-objects/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteBatterys/hwBattString/hwBattStringOperTable/hwBattStringOperEntry/hwBattStringOperStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Huawei MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 2 — Huawei MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1normal1, 2
2tempHigh1, 2
3tempLow1, 2
4loopBreak1, 2
5overCurrent1, 2
6unbalance1, 2
7discharge2
8fuseBreak2
254alarmResume1, 2
255other1
255unknown2

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In HUAWEI-SITE-MONITOR-MIB, the row index hwBattStringOperIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99.<hwBattStringOperIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

hwBattStringOperStatus · current

hwBattStringOperStatus OBJECT-TYPE
			SYNTAX INTEGER
				{
				normal(1),
				tempHigh(2),
				tempLow(3),
				loopBreak(4),
				overCurrent(5),
				unbalance(6),
				alarmResume(254),
				other(255)
				}
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"State of the site battery string module. It is an enumeration type: 
				If the enumeration value is 1, it indicates that the site battery string is in the normal state; 
				If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; 
				If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature;  
				If the enumeration value is 4, it indicates that battery string loop has disconnected;  
				If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold;
				If the enumeration value is 254, it indicates battery string alarm resume; 
				If the enumeration value is 255, it indicates battery string operation status unknown. "
			::= { hwBattStringOperEntry 99 }

hwBattStringOperStatus · current

hwBattStringOperStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                normal(1),
                tempHigh(2),
                tempLow(3),
                loopBreak(4),
                overCurrent(5),
                unbalance(6),
                discharge(7),
                fuseBreak(8),
                alarmResume(254),
                unknown(255)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "State of the site battery string module. It is an enumeration type: 
                  If the enumeration value is 1, it indicates that the site battery string is in the normal state; 
                  If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; 
                  If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature;  
                  If the enumeration value is 4, it indicates that battery string loop has disconnected;  
                  If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold;
                  If the enumeration value is 6, it indicates that the battery string is unbalance;  
                  If the enumeration value is 7, it indicates that battery string is discharge;  
                  If the enumeration value is 8, it indicates that battery string is fuseBreak;
                  If the enumeration value is 254, it indicates battery string alarm resume; 
                  If the enumeration value is 255, it indicates battery string operation status unknown. "
            ::= { hwBattStringOperEntry 99 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown.

Sources for this description

Huawei MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 6, it indicates that the battery string is unbalance; If the enumeration value is 7, it indicates that battery string is discharge; If the enumeration value is 8, it indicates that battery string is fuseBreak; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown.

Sources for this description

Huawei MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Huawei MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

hwBattStringOperStatus · currentHuawei MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hwBattStringOperStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hwBattStringOperStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "normal",
    "(",
    "1",
    ")",
    ",",
    "tempHigh",
    "(",
    "2",
    ")",
    ",",
    "tempLow",
    "(",
    "3",
    ")",
    ",",
    "loopBreak",
    "(",
    "4",
    ")",
    ",",
    "overCurrent",
    "(",
    "5",
    ")",
    ",",
    "unbalance",
    "(",
    "6",
    ")",
    ",",
    "alarmResume",
    "(",
    "254",
    ")",
    ",",
    "other",
    "(",
    "255",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown. \"",
    "::=",
    "{",
    "hwBattStringOperEntry",
    "99",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "normal",
            1
          ],
          [
            "tempHigh",
            2
          ],
          [
            "tempLow",
            3
          ],
          [
            "loopBreak",
            4
          ],
          [
            "overCurrent",
            5
          ],
          [
            "unbalance",
            6
          ],
          [
            "alarmResume",
            254
          ],
          [
            "other",
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Huawei MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

hwBattStringOperStatus · currentHuawei MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hwBattStringOperStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hwBattStringOperStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "normal",
    "(",
    "1",
    ")",
    ",",
    "tempHigh",
    "(",
    "2",
    ")",
    ",",
    "tempLow",
    "(",
    "3",
    ")",
    ",",
    "loopBreak",
    "(",
    "4",
    ")",
    ",",
    "overCurrent",
    "(",
    "5",
    ")",
    ",",
    "unbalance",
    "(",
    "6",
    ")",
    ",",
    "discharge",
    "(",
    "7",
    ")",
    ",",
    "fuseBreak",
    "(",
    "8",
    ")",
    ",",
    "alarmResume",
    "(",
    "254",
    ")",
    ",",
    "unknown",
    "(",
    "255",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 6, it indicates that the battery string is unbalance; If the enumeration value is 7, it indicates that battery string is discharge; If the enumeration value is 8, it indicates that battery string is fuseBreak; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown. \"",
    "::=",
    "{",
    "hwBattStringOperEntry",
    "99",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "normal",
            1
          ],
          [
            "tempHigh",
            2
          ],
          [
            "tempLow",
            3
          ],
          [
            "loopBreak",
            4
          ],
          [
            "overCurrent",
            5
          ],
          [
            "unbalance",
            6
          ],
          [
            "discharge",
            7
          ],
          [
            "fuseBreak",
            8
          ],
          [
            "alarmResume",
            254
          ],
          [
            "unknown",
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 6, it indicates that the battery string is unbalance; If the enumeration value is 7, it indicates that battery string is discharge; If the enumeration value is 8, it indicates that battery string is fuseBreak; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.2011)

Lwu Zhao

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.1 hwBattStringOperIndex00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.2 hwBattStringCurrent00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.3 hwBattStringRemainCapacityPercent00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.4 hwBattStringRemainCapacity00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.5 hwBattStringActualCapacity00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.6 hwBattStringTemprature00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.7 hwBattStringMidpointVoltage00
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.100 hwBattStringOperRowStatus00