Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwBattStringOperStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"1",
")",
",",
"tempHigh",
"(",
"2",
")",
",",
"tempLow",
"(",
"3",
")",
",",
"loopBreak",
"(",
"4",
")",
",",
"overCurrent",
"(",
"5",
")",
",",
"unbalance",
"(",
"6",
")",
",",
"discharge",
"(",
"7",
")",
",",
"fuseBreak",
"(",
"8",
")",
",",
"alarmResume",
"(",
"254",
")",
",",
"unknown",
"(",
"255",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 6, it indicates that the battery string is unbalance; If the enumeration value is 7, it indicates that battery string is discharge; If the enumeration value is 8, it indicates that battery string is fuseBreak; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown. \"",
"::=",
"{",
"hwBattStringOperEntry",
"99",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"normal",
1
],
[
"tempHigh",
2
],
[
"tempLow",
3
],
[
"loopBreak",
4
],
[
"overCurrent",
5
],
[
"unbalance",
6
],
[
"discharge",
7
],
[
"fuseBreak",
8
],
[
"alarmResume",
254
],
[
"unknown",
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the battery string is over upper alarm threshold of temperature; If the enumeration value is 3, it indicates that the battery string is under lower alarm threshold of temperature; If the enumeration value is 4, it indicates that battery string loop has disconnected; If the enumeration value is 5, it indicates that the current of batery is over upper charging threshold; If the enumeration value is 6, it indicates that the battery string is unbalance; If the enumeration value is 7, it indicates that battery string is discharge; If the enumeration value is 8, it indicates that battery string is fuseBreak; If the enumeration value is 254, it indicates battery string alarm resume; If the enumeration value is 255, it indicates battery string operation status unknown."
],
null,
null,
null,
null
]
}