OID reference

hwSetAcsUpperVoltLimit

1.3.6.1.4.1.2011.6.164.1.5.1.5

Description

Upper threshold of the AC voltage alarm, can be configured by users. Value range: 50 to 600, units: V, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. NOTE: There is linkage between hwSetAcsUpperVoltLimit and hwSetAcsLowerVoltLimit

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.2011.6.164.1.5.1 (hwAcDistributionsGroup)
Node code
5
Node name
hwSetAcsUpperVoltLimit
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.2011.6.164.1.5.1.5
URN notation
urn:oid:1.3.6.1.4.1.2011.6.164.1.5.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 2011 6 164 1 5 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) huawei(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) iMAP(2011) huaweiUtility(6) hwSiteMonitorMIB(164) hwSiteMonitorMIBObjects(1) hwSiteAcDistributions(5) hwAcDistributionsGroup(1) hwSetAcsUpperVoltLimit(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/2011/6/164/1/5/1/5
  • /ISO/Identified-Organization/6/1/4/1/2011/6/164/1/5/1/5
  • /ISO/3/6/1/4/1/2011/6/164/1/5/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/enterprises/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/enterprises/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/vendor-objects/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/identified-organization/dod/internet/private/vendor-objects/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/enterprises/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/enterprises/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/ldap-enterprise/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/ldap-enterprise/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/vendor-objects/huawei/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • /iso/org/dod/internet/private/vendor-objects/iMAP/huaweiUtility/hwSiteMonitorMIB/hwSiteMonitorMIBObjects/hwSiteAcDistributions/hwAcDistributionsGroup/hwSetAcsUpperVoltLimit
  • Additional combinations skipped.

SNMP properties

Value type
Unsigned32
Units
V
Maximum access defined by MIB
read-write
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Huawei MIB copies (LibreNMS/Observium Community)

Value type
Unsigned32
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
50–600

Variant 2 — Huawei MIB copies (LibreNMS/Observium Community)

Value type
Unsigned32
Units
V
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
60–500

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.2011.6.164.1.5.1.5.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

hwSetAcsUpperVoltLimit · current

hwSetAcsUpperVoltLimit OBJECT-TYPE
            SYNTAX Unsigned32 (50..600)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Upper threshold of the AC voltage alarm, can be configured by users. 
                Value range: 50 to 600, 
                units: V, 
                and the value is an integer (1).  
                If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
                NOTE: There is linkage between hwSetAcsUpperVoltLimit and hwSetAcsLowerVoltLimit"
            ::= { hwAcDistributionsGroup 5 }

hwSetAcsUpperVoltLimit · current

hwSetAcsUpperVoltLimit OBJECT-TYPE
			SYNTAX Unsigned32 (60..500)
			UNITS "V"
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"Upper threshold of the AC voltage alarm, can be configured by users. Value range: 60 to 500, unit: V, and the value is an integer (.0)."
			::= { hwAcDistributionsGroup 5 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Upper threshold of the AC voltage alarm, can be configured by users. Value range: 50 to 600, units: V, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. NOTE: There is linkage between hwSetAcsUpperVoltLimit and hwSetAcsLowerVoltLimit

Sources for this description

Huawei MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Upper threshold of the AC voltage alarm, can be configured by users. Value range: 60 to 500, unit: V, and the value is an integer (.0).

Sources for this description

Huawei MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Huawei MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

hwSetAcsUpperVoltLimit · currentHuawei MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hwSetAcsUpperVoltLimit

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hwSetAcsUpperVoltLimit",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "(",
    "50",
    ".",
    ".",
    "600",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Upper threshold of the AC voltage alarm, can be configured by users. Value range: 50 to 600, units: V, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. NOTE: There is linkage between hwSetAcsUpperVoltLimit and hwSetAcsLowerVoltLimit\"",
    "::=",
    "{",
    "hwAcDistributionsGroup",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32",
      [
        "integerSubType",
        [
          [
            50,
            600
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Upper threshold of the AC voltage alarm, can be configured by users. Value range: 50 to 600, units: V, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. NOTE: There is linkage between hwSetAcsUpperVoltLimit and hwSetAcsLowerVoltLimit"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Huawei MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

hwSetAcsUpperVoltLimit · currentHuawei MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hwSetAcsUpperVoltLimit

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hwSetAcsUpperVoltLimit",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "(",
    "60",
    ".",
    ".",
    "500",
    ")",
    "UNITS",
    [
      "literal",
      "225622"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Upper threshold of the AC voltage alarm, can be configured by users. Value range: 60 to 500, unit: V, and the value is an integer (.0).\"",
    "::=",
    "{",
    "hwAcDistributionsGroup",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32",
      [
        "integerSubType",
        [
          [
            60,
            500
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "V"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Upper threshold of the AC voltage alarm, can be configured by users. Value range: 60 to 500, unit: V, and the value is an integer (.0)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.2011)

Lwu Zhao

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.2011.6.164.1.5.1.1 hwAcsGroupId00
1.3.6.1.4.1.2011.6.164.1.5.1.2 hwAcsGroupName00
1.3.6.1.4.1.2011.6.164.1.5.1.3 hwAcsTotalCurrent00
1.3.6.1.4.1.2011.6.164.1.5.1.4 hwAcsTotalQuantity, hwAcsInputQuantity00
1.3.6.1.4.1.2011.6.164.1.5.1.6 hwSetAcsLowerVoltLimit00
1.3.6.1.4.1.2011.6.164.1.5.1.7 hwAcsPowerConsumption00
1.3.6.1.4.1.2011.6.164.1.5.1.8 hwAcsPowerConsumptionHigh32b00
1.3.6.1.4.1.2011.6.164.1.5.1.9 hwAcsReactivePowerConsumption00
1.3.6.1.4.1.2011.6.164.1.5.1.10 hwAcsReactivePowerConsumptionHigh32b00
1.3.6.1.4.1.2011.6.164.1.5.1.11 hwAcsActivePowerConsumptionKw00
1.3.6.1.4.1.2011.6.164.1.5.1.12 hwAcsReactivePowerConsumptionKvar00