Description 1
ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1).
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.5
ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1).
Identification
{1 3 6 1 4 1 2011 6 164 1 5 2 1 1 5}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In HUAWEI-SITE-MONITOR-MIB, the row index hwAcInputIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.5.<hwAcInputIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
hwBpOrBclVoltage OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1)."
::= { hwAcInputEntry 5 }hwBpOrBclVoltage OBJECT-TYPE
SYNTAX Unsigned32 (0..6000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ACU B-phase or BC-line voltage.
Value range: 0 to 600,
units: V,
and the value is accurate to one decimal place (.1).
If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid."
::= { hwAcInputEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1).
Huawei MIB copies (LibreNMS/Observium Community)
Description 2
ACU B-phase or BC-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: hwBpOrBclVoltage
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwBpOrBclVoltage",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"5000",
")",
"UNITS",
[
"literal",
"225622"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1).\"",
"::=",
"{",
"hwAcInputEntry",
"5",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
5000
]
]
]
],
[
"UNITS",
"V"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Huawei support.
Module: HUAWEI-SITE-MONITOR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: current.
Names: hwBpOrBclVoltage
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwBpOrBclVoltage",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"6000",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"ACU B-phase or BC-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.\"",
"::=",
"{",
"hwAcInputEntry",
"5",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
6000
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"ACU B-phase or BC-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: EMAP-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.1 | hwAcInputIndex | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.2 | hwAcEquipId | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.3 | hwAcEquipName | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.4 | hwApOrAblVoltage | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.6 | hwCpOrCalVoltage | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.7 | hwAphaseCurrent | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.8 | hwBphaseCurrent | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.9 | hwCphaseCurrent | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.10 | hwAcInputBreakersQuantity | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99 | hwAcInputOperStatus | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.100 | hwAcRowStatus | 0 | 0 |