Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.2
Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device.
Identification
{1 3 6 1 4 1 2011 6 164 1 6 2 2 1 2}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In HUAWEI-SITE-MONITOR-MIB, the row index consists of these components in order:
hwDcOutputIndex (Integer32): one numeric subidentifier for the non-negative value.hwLoadBranchIndex (Integer32): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.2.<hwDcOutputIndex>.<hwLoadBranchIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
Published row index variants: hwDcOutputIndex, hwLoadBranchIndex; hwLoadBranchIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
hwLoadBranchEquipId OBJECT-TYPE
SYNTAX Unsigned32 (7001..7100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device. "
::= { hwLoadBranchEntry 2 }hwLoadBranchEquipId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device. "
::= { hwLoadBranchEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: hwLoadBranchEquipId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwLoadBranchEquipId",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"7001",
".",
".",
"7100",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device. \"",
"::=",
"{",
"hwLoadBranchEntry",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
7001,
7100
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Huawei support.
Module: HUAWEI-SITE-MONITOR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: current.
Names: hwLoadBranchEquipId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwLoadBranchEquipId",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device. \"",
"::=",
"{",
"hwLoadBranchEntry",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: EMAP-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.1 | hwLoadBranchIndex | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.3 | hwLoadBranchEquipName | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.4 | hwLoadBranchCurrent | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.5 | hwLoadBranchPower | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.6 | hwLoadBranchConsume | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.8 | hwLoadBranchConsumption | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.9 | hwLoadBranchConsumptionLow32b | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.10 | hwLoadBranchConsumptionHigh32b | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.99 | hwLoadBranchOperStatus | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.100 | hwLoadBranchRowStatus | 0 | 0 |