Phase C input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.6.174.1.3.100.1.10
Phase C input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco.
Identification
{1 3 6 1 4 1 2011 6 174 1 3 100 1 10}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: hwUpsDeviceId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2011.6.174.1.3.100.1.10
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
hwUpsInputPowerFactorC OBJECT-TYPE
SYNTAX Integer32 ( -100..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C input power factor. The value ranges from -100 to 100.
The value is accurate to one decimal place on the NetEco."
::= { hwUpsInputEntry 10 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Phase C input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: hwUpsInputPowerFactorC
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwUpsInputPowerFactorC",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"100",
".",
".",
"100",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Phase C input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco.\"",
"::=",
"{",
"hwUpsInputEntry",
"10",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-100,
100
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Phase C input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: HUAWEI-UPS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.1 | hwUpsInputVoltageA | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.2 | hwUpsInputVoltageB | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.3 | hwUpsInputVoltageC | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.4 | hwUpsInputFrequency | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.5 | hwUpsInputCurrentA | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.6 | hwUpsInputCurrentB | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.7 | hwUpsInputCurrentC | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.8 | hwUpsInputPowerFactorA | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.9 | hwUpsInputPowerFactorB | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.11 | hwUpsInputLineVoltageAB | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.12 | hwUpsInputLineVoltageBC | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.13 | hwUpsInputLineVoltageCA | 0 | 0 | |
| 1.3.6.1.4.1.2011.6.174.1.3.100.1.100 | hwUpsInputRowStatus | 0 | 0 |