Rack phase B output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.6.174.1.4.100.1.9
Rack phase B output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW.
Identification
{1 3 6 1 4 1 2011 6 174 1 4 100 1 9}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: hwUpsDeviceId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2011.6.174.1.4.100.1.9
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
hwUpsOutputActivePowerB OBJECT-TYPE
SYNTAX Integer32 ( -12000..12000)
UNITS "kW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rack phase B output active power. The value ranges from -12000 to 12000.
The value is accurate to one decimal place on the NetEco. The unit is kW."
::= { hwUpsOutputEntry 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Rack phase B output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: hwUpsOutputActivePowerB
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwUpsOutputActivePowerB",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"12000",
".",
".",
"12000",
")",
"UNITS",
[
"literal",
"226b5722"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Rack phase B output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW.\"",
"::=",
"{",
"hwUpsOutputEntry",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-12000,
12000
]
]
]
],
[
"UNITS",
"kW"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Rack phase B output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: HUAWEI-UPS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'HUAWEI-MIB': ['huaweiUtility'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration