OID reference

portFlowCtrlCfg

1.3.6.1.4.1.202.20.66.1.2.1.1.5

Description

(1) Flow control mechanism is enabled with tx and rx pause mechansim. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. I…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.202.20.66.1.2.1.1 (portEntry)
Node code
5
Node name
portFlowCtrlCfg
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.202.20.66.1.2.1.1.5
URN notation
urn:oid:1.3.6.1.4.1.202.20.66.1.2.1.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 202 20 66 1 2 1 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) smc(202) smcSwitches(20) smc6152L2MIB(66) smc6152L2MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portFlowCtrlCfg(5)}
OID-IRI notation
  • /1/3/6/1/4/1/202/20/66/1/2/1/1/5
  • /ISO/Identified-Organization/6/1/4/1/202/20/66/1/2/1/1/5
  • /ISO/3/6/1/4/1/202/20/66/1/2/1/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/identified-organization/dod/internet/private/enterprises/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/identified-organization/dod/internet/private/vendor-objects/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/org/dod/internet/private/enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/org/dod/internet/private/enterprises/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/org/dod/internet/private/ldap-enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/org/dod/internet/private/vendor-objects/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-identified-organization/dod/internet/private/enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-identified-organization/dod/internet/private/enterprises/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-organization/dod/internet/private/enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-organization/dod/internet/private/enterprises/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg
  • /iso/iso-organization/dod/internet/private/vendor-objects/smc/smcSwitches/smc6152L2MIB/smc6152L2MIBObjects/portMgt/portTable/portEntry/portFlowCtrlCfg

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
disabled

Enumerated values

ValueName
1enabled
2disabled
5tx
6rx

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In SMC6152L2-MIB, the row index portIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.202.20.66.1.2.1.1.5.<portIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.202.20.66.1.2.1.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

portFlowCtrlCfg OBJECT-TYPE
        SYNTAX      INTEGER
                    {
                        enabled(1),
                        disabled(2),
                        tx(5),
                        rx(6)
                    }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "(1) Flow control mechanism is enabled with tx and rx pause
                         mechansim.
                         If the port type is hundredBaseTX or thousandBaseSX:
                         When the port is operating in halfDuplex mode, the
                         port uses backPressure flow control mechanism. When
                         the port is operating in fullDuplex mode, the port
                         uses IEEE 802.3x flow control mechanism.
                         If the port type is hundredBaseFX:
                         When the port is operating in halfDuplex mode, the
                         port uses backPressure flow control mechanism. When
                         the port is operating in fullDuplex mode, Flow
                         control mechanism will not function.
                     (2) Flow control mechanism is disabled.
                     (5) Flow control mechanism is enabled with tx pause
                         mechanism only.
                     (6) Flow control mechansim is enabled with rx pause
                         mechansim only.

                     Fast ethernet ports can be set as:
                         enabled(1),
                         disabled(2).
                     Gigabit ethernet ports can be set as:
                         enabled(1),
                         disabled(2),
                         tx(5),
                         rx(6).
                     The actual flow control mechanism is used given by
                     portFlowCtrlStatus."
        DEFVAL      { disabled }
        ::= { portEntry 5 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

(1) Flow control mechanism is enabled with tx and rx pause mechansim. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (5) Flow control mechanism is enabled with tx pause mechanism only. (6) Flow control mechansim is enabled with rx pause mechansim only. Fast ethernet ports can be set as: enabled(1), disabled(2). Gigabit ethernet ports can be set as: enabled(1), disabled(2), tx(5), rx(6). The actual flow control mechanism is used given by portFlowCtrlStatus.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

portFlowCtrlCfg · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: portFlowCtrlCfg

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "portFlowCtrlCfg",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "enabled",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "tx",
    "(",
    "5",
    ")",
    ",",
    "rx",
    "(",
    "6",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"(1) Flow control mechanism is enabled with tx and rx pause mechansim. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (5) Flow control mechanism is enabled with tx pause mechanism only. (6) Flow control mechansim is enabled with rx pause mechansim only. Fast ethernet ports can be set as: enabled(1), disabled(2). Gigabit ethernet ports can be set as: enabled(1), disabled(2), tx(5), rx(6). The actual flow control mechanism is used given by portFlowCtrlStatus.\"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "portEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "enabled",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "tx",
            5
          ],
          [
            "rx",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "(1) Flow control mechanism is enabled with tx and rx pause mechansim. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (5) Flow control mechanism is enabled with tx pause mechanism only. (6) Flow control mechansim is enabled with rx pause mechansim only. Fast ethernet ports can be set as: enabled(1), disabled(2). Gigabit ethernet ports can be set as: enabled(1), disabled(2), tx(5), rx(6). The actual flow control mechanism is used given by portFlowCtrlStatus."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.202)

Sprung Lance

Siblings (10)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.202.20.66.1.2.1.1.1 portIndex00
1.3.6.1.4.1.202.20.66.1.2.1.1.2 portName00
1.3.6.1.4.1.202.20.66.1.2.1.1.3 portType00
1.3.6.1.4.1.202.20.66.1.2.1.1.4 portSpeedDpxCfg00
1.3.6.1.4.1.202.20.66.1.2.1.1.6 portCapabilities00
1.3.6.1.4.1.202.20.66.1.2.1.1.7 portAutonegotiation00
1.3.6.1.4.1.202.20.66.1.2.1.1.8 portSpeedDpxStatus00
1.3.6.1.4.1.202.20.66.1.2.1.1.9 portFlowCtrlStatus00
1.3.6.1.4.1.202.20.66.1.2.1.1.10 portTrunkIndex00
1.3.6.1.4.1.202.20.66.1.2.1.1.12 portComboForcedMode00