stackSlipAddr, and stackBootUpIP will not immediately enable parameters take
effect . They will take effect when ipInformationReset is set to reset(2).
OID reference
1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.13
Setting the stackIP, stackNetMask,stackGateway, stackSlipAddr, and stackBootUpIP will not immediately enable parameters take effect . They will take effect when ipInformationReset is set to reset(2).
Identification
{1 3 6 1 4 1 207 8 1 20 3 11 1 1 1 13}
| Value | Name |
|---|---|
| 1 | noReset |
| 2 | reset |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.13.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Historical records
ipInformationReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting the stackIP, stackNetMask,stackGateway,
stackSlipAddr, and stackBootUpIP will not immediately enable parameters take
effect . They will take effect when ipInformationReset is set to reset(2)."
::= { fh800uStackInfo 13 }
ipInformationReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting the stackIP, stackNetMask,stackGateway,
stackSlipAddr, and stackBootUpIP will not immediately enable parameters take
effect . They will take effect when ipInformationReset is set to reset(2)."
::= { fh800uStackInfo 13 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.13.0 | ipInformationReset | 0 | 0 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.1 | stackInusedIP | 1 | 1 | The IP address currently used by the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.2 | stackInusedNetMask | 1 | 1 | The subnet maskcurrently used by the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.3 | stackInusedGateway | 1 | 1 | The prefered gateway used to send traps. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.4 | stackInusedServerSlipAddr | 1 | 1 | The Server SLIP addresscurrently used by the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.5 | stackInusedHostSlipAddr | 1 | 1 | The Host SLIP address currently used by the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.6 | stackInusedBootUpIP | 1 | 1 | The Bootup IP address currently used by the Dual-Speed Hub system. The Bootup IP must reside in the same subnet as the stackIP. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.7 | stackTemporalIP | 1 | 1 | Used to change the IP address of the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.8 | stackTemporalNetMask | 1 | 1 | Used to change the subnet mask of the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.9 | stackTemporalGateway | 1 | 1 | Used to change the prefered gateway to send traps. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.10 | stackTemporalServerSlipAddr | 1 | 1 | Used to change the Server SLIP address of the Dual-Speed Hub system. The SLIP address must reside in the same subnet as the stac… |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.11 | stackTemporalHostSlipAddr | 1 | 1 | Used to change the Host SLIP address of the Dual-Speed Hub system. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.12 | stackTemporalBootUpIP | 1 | 1 | Used to change the Bootup IP address of the Dual-Speed Hub system. The Bootup IP must reside in the same subnet as the stackIP. |
| 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.14 | stackHealthMonitor | 1 | 1 | < FOR fh800u Dual-Speed Hub DEFINITION : > There are two kinds of hubs : 12 ports need (1+ 12 + 1 + 1 + 1 + 1 +1 +1 +1) 20 bytes … |