OID reference

fsPbPortSVlanClassificationMethod

1.3.6.1.4.1.2076.113.2.1.1.2

Description

This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.2076.113.2.1.1 (fsPbPortInfoEntry)
Node code
2
Node name
fsPbPortSVlanClassificationMethod
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.2076.113.2.1.1.2
URN notation
urn:oid:1.3.6.1.4.1.2076.113.2.1.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 2076 113 2 1 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 futureProviderBridgeMIB(113) fsPbConfig(2) fsPbPortInfoTable(1) fsPbPortInfoEntry(1) fsPbPortSVlanClassificationMethod(2)}
OID-IRI notation
  • /1/3/6/1/4/1/2076/113/2/1/1/2
  • /ISO/Identified-Organization/6/1/4/1/2076/113/2/1/1/2
  • /ISO/3/6/1/4/1/2076/113/2/1/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/identified-organization/dod/internet/private/enterprises/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/identified-organization/dod/internet/private/vendor-objects/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/org/dod/internet/private/enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/org/dod/internet/private/enterprises/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/org/dod/internet/private/ldap-enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/org/dod/internet/private/vendor-objects/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-identified-organization/dod/internet/private/enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-identified-organization/dod/internet/private/enterprises/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-organization/dod/internet/private/enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-organization/dod/internet/private/enterprises/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod
  • /iso/iso-organization/dod/internet/private/vendor-objects/2076/futureProviderBridgeMIB/fsPbConfig/fsPbPortInfoTable/fsPbPortInfoEntry/fsPbPortSVlanClassificationMethod

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

ValueName
1sourceMac
2destinationMac
3cvlanSrcMac
4cvlanDstMac
5dscp
6cvlanDscp
7sourceIp
8destinationIp
9srcIpDstIp
10cvlanDstIp
11cvlan
12pvid

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In ARICENT-PROVIDERBRIDGE-MIB, the row index fsPbPort is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2076.113.2.1.1.2.<fsPbPort>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

Published row index: fsPbPort.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2076.113.2.1.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

fsPbPortSVlanClassificationMethod · current

fsPbPortSVlanClassificationMethod OBJECT-TYPE
   SYNTAX      INTEGER {
                        sourceMac (1),
                        destinationMac (2),
                        cvlanSrcMac (3),
                        cvlanDstMac (4),
                        dscp (5),
                        cvlanDscp (6),
                        sourceIp (7),
                        destinationIp (8),
                        srcIpDstIp (9),
                        cvlanDstIp (10),
                        cvlan (11),
                        pvid (12)
    }
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
    "This object indicates the type of SVLAN classification that has to be used
     for a given type of port.

     providerNetworkPort / customerNetworkPort  -  Port's 'pvid' will be the
     SVLAN classification for the untagged packets received over this interface.

     customerEdgePort - The SVLAN classification mechanism is always based on
     'cvlan' (i.e CVidRegistrationTable ). No other SVLAN classification 
mechanism is
     allowed for this port type.

     propCustomerNetworkPort / propCustomerEdgePort  - 'pvid' will be
     default SVLAN classification mechanism for this port. But the user is
free to
     configure any other SVLAN classification mechanism except the
     CVidRegistrationTable (i.e. cvlan mechanism)

     For proprietary CEP and proprietary CNP ports, the SVLAN classification
     is based on one of the configured SVLAN classification methods mentioned
     here. If it is not configured, by default the port's 'PVID' is considered
     as the SVLAN for untagged packets."

   ::= { fsPbPortInfoEntry 2 }

fsPbPortSVlanClassificationMethod · current

fsPbPortSVlanClassificationMethod OBJECT-TYPE
   SYNTAX      INTEGER {
                        sourceMac (1),
                        destinationMac (2),
                        cvlanSrcMac (3),
                        cvlanDstMac (4),
                        dscp (5),
                        cvlanDscp (6),
                        sourceIp (7),
                        destinationIp (8),
                        srcIpDstIp (9),
                        cvlanDstIp (10),
                        cvlan (11),
                        pvid (12)
    }
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
    "This object indicates the type of SVLAN classification that has to be used
     for a given type of port.

     providerNetworkPort / customerNetworkPort  -  Port's 'pvid' will be the
     SVLAN classification for the untagged packets received over this interface.

     customerEdgePort - The SVLAN classification mechanism is always based on
     'cvlan' (i.e CVidRegistrationTable ).No other SVLAN classification mechanism is
     allowed for this port type.

     propCustomerNetworkPort / propCustomerEdgePort  - 'pvid' will be
     default SVLAN classification mechanism for this port. But the user is free to
     configure any other SVLAN classification mechanism except the
     CVidRegistrationTable (ie cvlan mechanism)

     For proprietary CEP and proprietary CNP ports,the SVLAN classification
     is based on one of the configured SVLAN classification methods mentioned
     here. If it is not configured, by default the port's 'PVID' is considered
     as the SVLAN for untagged packets."

   ::= { fsPbPortInfoEntry 2 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on 'cvlan' (i.e CVidRegistrationTable ). No other SVLAN classification mechanism is allowed for this port type. propCustomerNetworkPort / propCustomerEdgePort - 'pvid' will be default SVLAN classification mechanism for this port. But the user is free to configure any other SVLAN classification mechanism except the CVidRegistrationTable (i.e. cvlan mechanism) For proprietary CEP and proprietary CNP ports, the SVLAN classification is based on one of the configured SVLAN classification methods mentioned here. If it is not configured, by default the port's 'PVID' is considered as the SVLAN for untagged packets.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on 'cvlan' (i.e CVidRegistrationTable ).No other SVLAN classification mechanism is allowed for this port type. propCustomerNetworkPort / propCustomerEdgePort - 'pvid' will be default SVLAN classification mechanism for this port. But the user is free to configure any other SVLAN classification mechanism except the CVidRegistrationTable (ie cvlan mechanism) For proprietary CEP and proprietary CNP ports,the SVLAN classification is based on one of the configured SVLAN classification methods mentioned here. If it is not configured, by default the port's 'PVID' is considered as the SVLAN for untagged packets.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

fsPbPortSVlanClassificationMethod · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: fsPbPortSVlanClassificationMethod

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fsPbPortSVlanClassificationMethod",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "sourceMac",
    "(",
    "1",
    ")",
    ",",
    "destinationMac",
    "(",
    "2",
    ")",
    ",",
    "cvlanSrcMac",
    "(",
    "3",
    ")",
    ",",
    "cvlanDstMac",
    "(",
    "4",
    ")",
    ",",
    "dscp",
    "(",
    "5",
    ")",
    ",",
    "cvlanDscp",
    "(",
    "6",
    ")",
    ",",
    "sourceIp",
    "(",
    "7",
    ")",
    ",",
    "destinationIp",
    "(",
    "8",
    ")",
    ",",
    "srcIpDstIp",
    "(",
    "9",
    ")",
    ",",
    "cvlanDstIp",
    "(",
    "10",
    ")",
    ",",
    "cvlan",
    "(",
    "11",
    ")",
    ",",
    "pvid",
    "(",
    "12",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on 'cvlan' (i.e CVidRegistrationTable ). No other SVLAN classification mechanism is allowed for this port type. propCustomerNetworkPort / propCustomerEdgePort - 'pvid' will be default SVLAN classification mechanism for this port. But the user is free to configure any other SVLAN classification mechanism except the CVidRegistrationTable (i.e. cvlan mechanism) For proprietary CEP and proprietary CNP ports, the SVLAN classification is based on one of the configured SVLAN classification methods mentioned here. If it is not configured, by default the port's 'PVID' is considered as the SVLAN for untagged packets.\"",
    "::=",
    "{",
    "fsPbPortInfoEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "sourceMac",
            1
          ],
          [
            "destinationMac",
            2
          ],
          [
            "cvlanSrcMac",
            3
          ],
          [
            "cvlanDstMac",
            4
          ],
          [
            "dscp",
            5
          ],
          [
            "cvlanDscp",
            6
          ],
          [
            "sourceIp",
            7
          ],
          [
            "destinationIp",
            8
          ],
          [
            "srcIpDstIp",
            9
          ],
          [
            "cvlanDstIp",
            10
          ],
          [
            "cvlan",
            11
          ],
          [
            "pvid",
            12
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on 'cvlan' (i.e CVidRegistrationTable ). No other SVLAN classification mechanism is allowed for this port type. propCustomerNetworkPort / propCustomerEdgePort - 'pvid' will be default SVLAN classification mechanism for this port. But the user is free to configure any other SVLAN classification mechanism except the CVidRegistrationTable (i.e. cvlan mechanism) For proprietary CEP and proprietary CNP ports, the SVLAN classification is based on one of the configured SVLAN classification methods mentioned here. If it is not configured, by default the port's 'PVID' is considered as the SVLAN for untagged packets."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 1 source

Description 2

fsPbPortSVlanClassificationMethod · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs1 source

Status in source: current.

Names: fsPbPortSVlanClassificationMethod

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fsPbPortSVlanClassificationMethod",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "sourceMac",
    "(",
    "1",
    ")",
    ",",
    "destinationMac",
    "(",
    "2",
    ")",
    ",",
    "cvlanSrcMac",
    "(",
    "3",
    ")",
    ",",
    "cvlanDstMac",
    "(",
    "4",
    ")",
    ",",
    "dscp",
    "(",
    "5",
    ")",
    ",",
    "cvlanDscp",
    "(",
    "6",
    ")",
    ",",
    "sourceIp",
    "(",
    "7",
    ")",
    ",",
    "destinationIp",
    "(",
    "8",
    ")",
    ",",
    "srcIpDstIp",
    "(",
    "9",
    ")",
    ",",
    "cvlanDstIp",
    "(",
    "10",
    ")",
    ",",
    "cvlan",
    "(",
    "11",
    ")",
    ",",
    "pvid",
    "(",
    "12",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on 'cvlan' (i.e CVidRegistrationTable ).No other SVLAN classification mechanism is allowed for this port type. propCustomerNetworkPort / propCustomerEdgePort - 'pvid' will be default SVLAN classification mechanism for this port. But the user is free to configure any other SVLAN classification mechanism except the CVidRegistrationTable (ie cvlan mechanism) For proprietary CEP and proprietary CNP ports,the SVLAN classification is based on one of the configured SVLAN classification methods mentioned here. If it is not configured, by default the port's 'PVID' is considered as the SVLAN for untagged packets.\"",
    "::=",
    "{",
    "fsPbPortInfoEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "sourceMac",
            1
          ],
          [
            "destinationMac",
            2
          ],
          [
            "cvlanSrcMac",
            3
          ],
          [
            "cvlanDstMac",
            4
          ],
          [
            "dscp",
            5
          ],
          [
            "cvlanDscp",
            6
          ],
          [
            "sourceIp",
            7
          ],
          [
            "destinationIp",
            8
          ],
          [
            "srcIpDstIp",
            9
          ],
          [
            "cvlanDstIp",
            10
          ],
          [
            "cvlan",
            11
          ],
          [
            "pvid",
            12
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object indicates the type of SVLAN classification that has to be used for a given type of port. providerNetworkPort / customerNetworkPort - Port's 'pvid' will be the SVLAN classification for the untagged packets received over this interface. customerEdgePort - The SVLAN classification mechanism is always based on 'cvlan' (i.e CVidRegistrationTable ).No other SVLAN classification mechanism is allowed for this port type. propCustomerNetworkPort / propCustomerEdgePort - 'pvid' will be default SVLAN classification mechanism for this port. But the user is free to configure any other SVLAN classification mechanism except the CVidRegistrationTable (ie cvlan mechanism) For proprietary CEP and proprietary CNP ports,the SVLAN classification is based on one of the configured SVLAN classification methods mentioned here. If it is not configured, by default the port's 'PVID' is considered as the SVLAN for untagged packets."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.2076)

Division Products

Siblings (9)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.2076.113.2.1.1.1 fsPbPort00
1.3.6.1.4.1.2076.113.2.1.1.3 fsPbPortSVlanIngressEtherType00
1.3.6.1.4.1.2076.113.2.1.1.4 fsPbPortSVlanEgressEtherType00
1.3.6.1.4.1.2076.113.2.1.1.5 fsPbPortSVlanEtherTypeSwapStatus00
1.3.6.1.4.1.2076.113.2.1.1.6 fsPbPortSVlanTranslationStatus00
1.3.6.1.4.1.2076.113.2.1.1.7 fsPbPortUnicastMacLearning00
1.3.6.1.4.1.2076.113.2.1.1.8 fsPbPortUnicastMacLimit00
1.3.6.1.4.1.2076.113.2.1.1.9 fsPbPortBundleStatus00
1.3.6.1.4.1.2076.113.2.1.1.10 fsPbPortMultiplexStatus00