This object is used to identity the Uplink Failure Detection (UFD) Group-name.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2076.27.1.30.1.2
This object is used to identity the Uplink Failure Detection (UFD) Group-name.
Identification
{1 3 6 1 4 1 2076 27 1 30 1 2}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ARICENT-CFA-MIB, the row index ifUfdGroupId is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2076.27.1.30.1.2.<ifUfdGroupId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index: ifUfdGroupId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2076.27.1.30.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ifUfdGroupName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to identity the Uplink Failure Detection
(UFD) Group-name."
::= { ifUfdGroupEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object is used to identity the Uplink Failure Detection (UFD) Group-name.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: ifUfdGroupName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ifUfdGroupName",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"1",
".",
".",
"32",
")",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to identity the Uplink Failure Detection (UFD) Group-name.\"",
"::=",
"{",
"ifUfdGroupEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
1,
32
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to identity the Uplink Failure Detection (UFD) Group-name."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: ARICENT-CFA-MIB
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'ifEntry', 'ifType'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'RowStatus', 'TimeStamp', 'DisplayString', 'StorageType'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Counter64', 'enterprises', 'IpAddress', 'Unsigned32', 'Integer32', 'NOTIFICATION-TYPE', 'TimeTicks'], 'Q-BRIDGE-MIB': ['VlanId', 'PortList'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2076.27.1.30.1.1 | ifUfdGroupId | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.3 | ifUfdGroupStatus | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.4 | ifUfdGroupUplinkPorts | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.5 | ifUfdGroupDownlinkPorts | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.6 | ifUfdGroupDesigUplinkPort | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.7 | ifUfdGroupUplinkCount | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.8 | ifUfdGroupDownlinkCount | 0 | 0 | |
| 1.3.6.1.4.1.2076.27.1.30.1.9 | ifUfdGroupRowStatus | 0 | 0 |