Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"issPauseFloodTraceSeverityLevel",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"emergency",
"(",
"0",
")",
",",
"alert",
"(",
"1",
")",
",",
"critical",
"(",
"2",
")",
",",
"error",
"(",
"3",
")",
",",
"warning",
"(",
"4",
")",
",",
"notice",
"(",
"5",
")",
",",
"informational",
"(",
"6",
")",
",",
"debug",
"(",
"7",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object specifies the value of severity level been configured for pause flood module's debug tracing. It uses the value 0 (emergency) to 7 (debug). The value 0 is given to higher priority trace messages and 7 given to lower priority traces messages. The trace messages defined at or numerically lower than the value configured in this MIB object are logged.\"",
"DEFVAL",
"{",
"4",
"}",
"::=",
"{",
"issSystem",
"125",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"emergency",
0
],
[
"alert",
1
],
[
"critical",
2
],
[
"error",
3
],
[
"warning",
4
],
[
"notice",
5
],
[
"informational",
6
],
[
"debug",
7
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object specifies the value of severity level been configured for pause flood module's debug tracing. It uses the value 0 (emergency) to 7 (debug). The value 0 is given to higher priority trace messages and 7 given to lower priority traces messages. The trace messages defined at or numerically lower than the value configured in this MIB object are logged."
],
null,
null,
null,
[
"DEFVAL",
4
]
]
}