OID reference

issConfigIncrSaveFlag

1.3.6.1.4.1.2076.81.1.44

Description

Indicates whether SNMP Update Trigger for Incremental Save shall be generated or not. 'True' value implies that the update trigger shall be generated each time a nmhSet operation is successful. 'False' value implies that the update trigger shall not be generated at all. Following table explains the combinations of var…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.2076.81.1 (issSystem)
Node code
44
Node name
issConfigIncrSaveFlag
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.2076.81.1.44
URN notation
urn:oid:1.3.6.1.4.1.2076.81.1.44
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 2076 81 1 44}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 2076 iss(81) issSystem(1) issConfigIncrSaveFlag(44)}
OID-IRI notation
  • /1/3/6/1/4/1/2076/81/1/44
  • /ISO/Identified-Organization/6/1/4/1/2076/81/1/44
  • /ISO/3/6/1/4/1/2076/81/1/44
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/identified-organization/dod/internet/private/enterprises/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/identified-organization/dod/internet/private/vendor-objects/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/org/dod/internet/private/enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/org/dod/internet/private/enterprises/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/org/dod/internet/private/ldap-enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/org/dod/internet/private/vendor-objects/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-identified-organization/dod/internet/private/enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-identified-organization/dod/internet/private/enterprises/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-organization/dod/internet/private/enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-organization/dod/internet/private/enterprises/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/2076/iss/issSystem/issConfigIncrSaveFlag
  • /iso/iso-organization/dod/internet/private/vendor-objects/2076/iss/issSystem/issConfigIncrSaveFlag

SNMP properties

Value type
TruthValue
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
false

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

issConfigIncrSaveFlag · current

issConfigIncrSaveFlag OBJECT-TYPE
   SYNTAX      TruthValue
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
       "Indicates whether SNMP Update Trigger for Incremental Save shall be generated or not.
        'True' value implies that the update trigger shall be generated each time a nmhSet 
         operation is successful.
        'False' value implies that the update trigger shall not be generated at all.

   Following table explains the combinations of various configurations 
   ============================================================================
   issConfig      issConfig       issConfig
   IncrSaveFlag  AutoSaveTrigger  SaveOption    Behaviour
   ============================================================================
   TRUE          TRUE             Remote Save   tftp to remote (on every update trigger)
   TRUE          FALSE            Remote Save   tftp to remote (operator triggered)
   FALSE         xx               Remote Save   tftp to remote (operator triggered)
   TRUE          TRUE             Flash Save    save to local (on every update trigger)
   TRUE          FALSE            Flash Save    save to local (operator triggered)
   FALSE         xx               Flash Save    save to local (operator triggered)
   TRUE          TRUE             No Save       Data added to RB Tree
   TRUE          FALSE            No Save       Data added to RB Tree
   FALSE         xx               No Save       No Update trigger is sent to MSR
   ============================================================================
        
        The configuration of the issConfigIncrSaveFlag object from true to false
        or vice versa will be used only after switch restart.

		As the auto save of configurations cannot be used when the
		issConfigIncrSaveFlag is set to false, the issConfigAutoSaveTrigger
		has to be set to false before setting the issConfigIncrSaveFlag
		to false."
   DEFVAL  { false }
   ::= { issSystem 44 }

issConfigIncrSaveFlag · current

issConfigIncrSaveFlag OBJECT-TYPE
   SYNTAX      TruthValue
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
       "Indicates whether SNMP Update Trigger for Incremental Save shall be generated or not.
        'True' value implies that the update trigger shall be generated each time a nmhSet
         operation is successful.
        'False' value implies that the update trigger shall not be generated at all.

   Following table explains the combinations of various configurations
   ============================================================================
   issConfig      issConfig       issConfig
   IncrSaveFlag  AutoSaveTrigger  SaveOption    Behaviour
   ============================================================================
   TRUE          TRUE             Remote Save   tftp to remote (on every update trigger)
   TRUE          FALSE            Remote Save   tftp to remote (operator triggered)
   FALSE         xx               Remote Save   tftp to remote (operator triggered)
   TRUE          TRUE             Flash Save    save to local (on every update trigger)
   TRUE          FALSE            Flash Save    save to local (operator triggered)
   FALSE         xx               Flash Save    save to local (operator triggered)
   TRUE          TRUE             No Save       Data added to RB Tree
   TRUE          FALSE            No Save       Data added to RB Tree
   FALSE         xx               No Save       No Update trigger is sent to MSR
   ============================================================================

        The configuration of the issConfigIncrSaveFlag object from true to false
        or vice versa will be used only after switch restart.

		As the auto save of configurations cannot be used when the
		issConfigIncrSaveFlag is set to false, the issConfigAutoSaveTrigger
		has to be set to false before setting the issConfigIncrSaveFlag
		to false."
   DEFVAL  { false }
   ::= { issSystem 44 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Indicates whether SNMP Update Trigger for Incremental Save shall be generated or not. 'True' value implies that the update trigger shall be generated each time a nmhSet operation is successful. 'False' value implies that the update trigger shall not be generated at all. Following table explains the combinations of various configurations ============================================================================ issConfig issConfig issConfig IncrSaveFlag AutoSaveTrigger SaveOption Behaviour ============================================================================ TRUE TRUE Remote Save tftp to remote (on every update trigger) TRUE FALSE Remote Save tftp to remote (operator triggered) FALSE xx Remote Save tftp to remote (operator triggered) TRUE TRUE Flash Save save to local (on every update trigger) TRUE FALSE Flash Save save to local (operator triggered) FALSE xx Flash Save save to local (operator triggered) TRUE TRUE No Save Data added to RB Tree TRUE FALSE No Save Data added to RB Tree FALSE xx No Save No Update trigger is sent to MSR ============================================================================ The configuration of the issConfigIncrSaveFlag object from true to false or vice versa will be used only after switch restart. As the auto save of configurations cannot be used when the issConfigIncrSaveFlag is set to false, the issConfigAutoSaveTrigger has to be set to false before setting the issConfigIncrSaveFlag to false.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 4 sources

Description 1

issConfigIncrSaveFlag · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Belden, GarrettCom and Hirschmann IT official standalone MIBs4 sources

Status in source: current.

Names: issConfigIncrSaveFlag

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "issConfigIncrSaveFlag",
    "OBJECT-TYPE",
    "SYNTAX",
    "TruthValue",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Indicates whether SNMP Update Trigger for Incremental Save shall be generated or not. 'True' value implies that the update trigger shall be generated each time a nmhSet operation is successful. 'False' value implies that the update trigger shall not be generated at all. Following table explains the combinations of various configurations ============================================================================ issConfig issConfig issConfig IncrSaveFlag AutoSaveTrigger SaveOption Behaviour ============================================================================ TRUE TRUE Remote Save tftp to remote (on every update trigger) TRUE FALSE Remote Save tftp to remote (operator triggered) FALSE xx Remote Save tftp to remote (operator triggered) TRUE TRUE Flash Save save to local (on every update trigger) TRUE FALSE Flash Save save to local (operator triggered) FALSE xx Flash Save save to local (operator triggered) TRUE TRUE No Save Data added to RB Tree TRUE FALSE No Save Data added to RB Tree FALSE xx No Save No Update trigger is sent to MSR ============================================================================ The configuration of the issConfigIncrSaveFlag object from true to false or vice versa will be used only after switch restart. As the auto save of configurations cannot be used when the issConfigIncrSaveFlag is set to false, the issConfigAutoSaveTrigger has to be set to false before setting the issConfigIncrSaveFlag to false.\"",
    "DEFVAL",
    "{",
    "false",
    "}",
    "::=",
    "{",
    "issSystem",
    "44",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "TruthValue"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Indicates whether SNMP Update Trigger for Incremental Save shall be generated or not. 'True' value implies that the update trigger shall be generated each time a nmhSet operation is successful. 'False' value implies that the update trigger shall not be generated at all. Following table explains the combinations of various configurations ============================================================================ issConfig issConfig issConfig IncrSaveFlag AutoSaveTrigger SaveOption Behaviour ============================================================================ TRUE TRUE Remote Save tftp to remote (on every update trigger) TRUE FALSE Remote Save tftp to remote (operator triggered) FALSE xx Remote Save tftp to remote (operator triggered) TRUE TRUE Flash Save save to local (on every update trigger) TRUE FALSE Flash Save save to local (operator triggered) FALSE xx Flash Save save to local (operator triggered) TRUE TRUE No Save Data added to RB Tree TRUE FALSE No Save Data added to RB Tree FALSE xx No Save No Update trigger is sent to MSR ============================================================================ The configuration of the issConfigIncrSaveFlag object from true to false or vice versa will be used only after switch restart. As the auto save of configurations cannot be used when the issConfigIncrSaveFlag is set to false, the issConfigAutoSaveTrigger has to be set to false before setting the issConfigIncrSaveFlag to false."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "false"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.2076)

Division Products

Siblings (137)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.2076.81.1.1 issSwitchName00
1.3.6.1.4.1.2076.81.1.2 issHardwareVersion00
1.3.6.1.4.1.2076.81.1.3 issFirmwareVersion00
1.3.6.1.4.1.2076.81.1.4 issDefaultIpAddrCfgMode00
1.3.6.1.4.1.2076.81.1.5 issDefaultIpAddr00
1.3.6.1.4.1.2076.81.1.6 issDefaultIpSubnetMask00
1.3.6.1.4.1.2076.81.1.7 issEffectiveIpAddr00
1.3.6.1.4.1.2076.81.1.8 issDefaultInterface00
1.3.6.1.4.1.2076.81.1.9 issRestart00
1.3.6.1.4.1.2076.81.1.10 issConfigSaveOption00
1.3.6.1.4.1.2076.81.1.11 issConfigSaveIpAddr00
1.3.6.1.4.1.2076.81.1.12 issConfigSaveFileName00
1.3.6.1.4.1.2076.81.1.13 issInitiateConfigSave00
1.3.6.1.4.1.2076.81.1.14 issConfigSaveStatus00
1.3.6.1.4.1.2076.81.1.15 issConfigRestoreOption00
1.3.6.1.4.1.2076.81.1.16 issConfigRestoreIpAddr00
1.3.6.1.4.1.2076.81.1.17 issConfigRestoreFileName00
1.3.6.1.4.1.2076.81.1.18 issInitiateConfigRestore00
1.3.6.1.4.1.2076.81.1.19 issConfigRestoreStatus00
1.3.6.1.4.1.2076.81.1.20 issDlImageFromIp00
1.3.6.1.4.1.2076.81.1.21 issDlImageName00
1.3.6.1.4.1.2076.81.1.22 issInitiateDlImage00
1.3.6.1.4.1.2076.81.1.23 issLoggingOption00
1.3.6.1.4.1.2076.81.1.24 issUploadLogFileToIp00
1.3.6.1.4.1.2076.81.1.25 issLogFileName00
1.3.6.1.4.1.2076.81.1.26 issInitiateUlLogFile00
1.3.6.1.4.1.2076.81.1.27 issRemoteSaveStatus00
1.3.6.1.4.1.2076.81.1.28 issDownloadStatus00
1.3.6.1.4.1.2076.81.1.29 issSysContact00
1.3.6.1.4.1.2076.81.1.30 issSysLocation00
1.3.6.1.4.1.2076.81.1.31 issLoginAuthentication00
1.3.6.1.4.1.2076.81.1.32 issSwitchBaseMacAddress00
1.3.6.1.4.1.2076.81.1.33 issOOBInterface00
1.3.6.1.4.1.2076.81.1.34 issSwitchDate00
1.3.6.1.4.1.2076.81.1.35 issNoCliConsole00
1.3.6.1.4.1.2076.81.1.36 issDefaultIpAddrAllocProtocol00
1.3.6.1.4.1.2076.81.1.37 issHttpPort00
1.3.6.1.4.1.2076.81.1.38 issHttpStatus00
1.3.6.1.4.1.2076.81.1.39 issConfigRestoreFileVersion00
1.3.6.1.4.1.2076.81.1.40 issDefaultRmIfName00
1.3.6.1.4.1.2076.81.1.41 issDefaultVlanId00
1.3.6.1.4.1.2076.81.1.42 issNpapiMode00
1.3.6.1.4.1.2076.81.1.43 issConfigAutoSaveTrigger00
1.3.6.1.4.1.2076.81.1.45 issConfigRollbackFlag00
1.3.6.1.4.1.2076.81.1.46 issConfigSyncUpOperation00
1.3.6.1.4.1.2076.81.1.47 issFrontPanelPortCount00
1.3.6.1.4.1.2076.81.1.48 issAuditLogStatus00
1.3.6.1.4.1.2076.81.1.49 issAuditLogFileName00
1.3.6.1.4.1.2076.81.1.50 issAuditLogFileSize00
1.3.6.1.4.1.2076.81.1.51 issAuditLogReset00