Lambda corresponding to receive frequency.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.211.1.24.12.700.200.1.1.11
Lambda corresponding to receive frequency.
Identification
{1 3 6 1 4 1 211 1 24 12 700 200 1 1 11}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ochLambda-rx OBJECT-TYPE
SYNTAX ConfdString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Lambda corresponding to receive frequency."
::= { och-dataEntry 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Lambda corresponding to receive frequency.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: ochLambda-rx
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ochLambda-rx",
"OBJECT-TYPE",
"SYNTAX",
"ConfdString",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Lambda corresponding to receive frequency.\"",
"::=",
"{",
"och-dataEntry",
"11",
"}"
],
"syntax_tree": [
[
"row",
"ConfdString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Lambda corresponding to receive frequency."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: FSS-OPTICAL-CHANNEL-INTERFACE
See published definition above
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'DateAndTime', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'Counter64', 'Gauge32', 'IpAddress'], 'FSS-COMMON-SMI': ['fssInterfaces']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.1 | ochOper-status | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.2 | ochAdmin-status | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.3 | ochCenter-frequency | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.4 | ochDirection | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.5 | ochModulation-format | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.6 | ochAct-laser | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.7 | ochTx-target-power | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.8 | ochSlot-width | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.9 | ochLambda | 0 | 0 | |
| 1.3.6.1.4.1.211.1.24.12.700.200.1.1.10 | ochCenter-frequency-rx | 0 | 0 |