OID reference

sfdSetNotificationModeAlarmRfInLevelHigh

1.3.6.1.4.1.21222.1.4.1.2.10.2.2

Description

Select which status-change of sfdMsrAlarmRfInLevelHigh sends a notification. 1 = off (no notification will be sent when value changes) 2 = warning (notification only send when value changes from idle to warning state or problem solves) 3 = warningAndAlarm (notification send when value changes from idle to warning or a…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.21222.1.4.1.2.10.2 (sfdSetNotificationModeAlarm)
Node code
2
Node name
sfdSetNotificationModeAlarmRfInLevelHigh
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.21222.1.4.1.2.10.2.2
URN notation
urn:oid:1.3.6.1.4.1.21222.1.4.1.2.10.2.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 21222 1 4 1 2 10 2 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) profline(21222) products(1) demodulators(4) sfd(1) sfdSettings(2) sfdSetNotification(10) sfdSetNotificationModeAlarm(2) sfdSetNotificationModeAlarmRfInLevelHigh(2)}
OID-IRI notation
  • /1/3/6/1/4/1/21222/1/4/1/2/10/2/2
  • /ISO/Identified-Organization/6/1/4/1/21222/1/4/1/2/10/2/2
  • /ISO/3/6/1/4/1/21222/1/4/1/2/10/2/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/enterprise/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/enterprises/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/enterprises/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/vendor-objects/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/identified-organization/dod/internet/private/vendor-objects/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/enterprise/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/enterprise/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/enterprises/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/enterprises/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/ldap-enterprise/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/ldap-enterprise/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/vendor-objects/21222/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • /iso/org/dod/internet/private/vendor-objects/profline/products/demodulators/sfd/sfdSettings/sfdSetNotification/sfdSetNotificationModeAlarm/sfdSetNotificationModeAlarmRfInLevelHigh
  • Additional combinations skipped.

SNMP properties

Value type
NotificationModes
Maximum access defined by MIB
read-write
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

sfdSetNotificationModeAlarmRfInLevelHigh OBJECT-TYPE
	SYNTAX		NotificationModes 
	MAX-ACCESS		read-write
	STATUS		current
	DESCRIPTION		"Select which status-change of sfdMsrAlarmRfInLevelHigh sends a notification.
				1 = off (no notification will be sent when value changes)
				2 = warning (notification only send when value changes from idle to warning state or problem solves)
				3 = warningAndAlarm (notification send when value changes from idle to warning or alarm state, or from warning to alarm state, or problem solves)
				4 = alarm (notification only send when value changes from idle to alarm state, or from warning to alarm state, or problem solves)"
	::= { sfdSetNotificationModeAlarm 2}

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Select which status-change of sfdMsrAlarmRfInLevelHigh sends a notification. 1 = off (no notification will be sent when value changes) 2 = warning (notification only send when value changes from idle to warning state or problem solves) 3 = warningAndAlarm (notification send when value changes from idle to warning or alarm state, or from warning to alarm state, or problem solves) 4 = alarm (notification only send when value changes from idle to alarm state, or from warning to alarm state, or problem solves)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

sfdSetNotificationModeAlarmRfInLevelHigh · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: sfdSetNotificationModeAlarmRfInLevelHigh

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sfdSetNotificationModeAlarmRfInLevelHigh",
    "OBJECT-TYPE",
    "SYNTAX",
    "NotificationModes",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Select which status-change of sfdMsrAlarmRfInLevelHigh sends a notification. 1 = off (no notification will be sent when value changes) 2 = warning (notification only send when value changes from idle to warning state or problem solves) 3 = warningAndAlarm (notification send when value changes from idle to warning or alarm state, or from warning to alarm state, or problem solves) 4 = alarm (notification only send when value changes from idle to alarm state, or from warning to alarm state, or problem solves)\"",
    "::=",
    "{",
    "sfdSetNotificationModeAlarm",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "NotificationModes"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Select which status-change of sfdMsrAlarmRfInLevelHigh sends a notification. 1 = off (no notification will be sent when value changes) 2 = warning (notification only send when value changes from idle to warning state or problem solves) 3 = warningAndAlarm (notification send when value changes from idle to warning or alarm state, or from warning to alarm state, or problem solves) 4 = alarm (notification only send when value changes from idle to alarm state, or from warning to alarm state, or problem solves)"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.21222)

Sengers Frank Peters

Siblings (9)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.21222.1.4.1.2.10.2.1 sfdSetNotificationModeAlarmRfInLevelLow00
1.3.6.1.4.1.21222.1.4.1.2.10.2.3 sfdSetNotificationModeAlarmPilotLevel00
1.3.6.1.4.1.21222.1.4.1.2.10.2.4 sfdSetNotificationModeAlarmMpxDeviation00
1.3.6.1.4.1.21222.1.4.1.2.10.2.5 sfdSetNotificationModeAlarmRdsBer00
1.3.6.1.4.1.21222.1.4.1.2.10.2.6 sfdSetNotificationModeAlarmRdsLevel00
1.3.6.1.4.1.21222.1.4.1.2.10.2.7 sfdSetNotificationModeAlarmAudioLevelLeft00
1.3.6.1.4.1.21222.1.4.1.2.10.2.8 sfdSetNotificationModeAlarmAudioLevelRight00
1.3.6.1.4.1.21222.1.4.1.2.10.2.9 sfdSetNotificationModeAlarmAudioLevelBoth00
1.3.6.1.4.1.21222.1.4.1.2.10.2.10 sfdSetNotificationModeAlarmRdsPi00