alarmCfgReadingID

1.3.6.1.4.1.21239.2.101.1.1.2

Description

OID of a particular measurement to monitor. This object is also used to create or delete a row. To create a new row, set the Sensor ID on a row that doesn\t exist. Set the ReadingID to 0.0 to destroy a row.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.21239.2.101.1.1 (alarmCfgEntry)
Node code
2
Node name
alarmCfgReadingID
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.21239.2.101.1.1.2
URN notation
urn:oid:1.3.6.1.4.1.21239.2.101.1.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 21239 2 101 1 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) geist(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) vertiv(21239) geistV3(2) alarmSystem(101) alarmCfgTable(1) alarmCfgEntry(1) alarmCfgReadingID(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/21239/2/101/1/1/2
  • /ISO/Identified-Organization/6/1/4/1/21239/2/101/1/1/2
  • /ISO/3/6/1/4/1/21239/2/101/1/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/21239/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/enterprise/geist/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/enterprise/vertiv/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/enterprises/21239/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/enterprises/geist/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/enterprises/vertiv/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/21239/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/geist/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/vertiv/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/vendor-objects/21239/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/vendor-objects/geist/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/identified-organization/dod/internet/private/vendor-objects/vertiv/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/org/dod/internet/private/enterprise/21239/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/org/dod/internet/private/enterprise/geist/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/org/dod/internet/private/enterprise/vertiv/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • /iso/org/dod/internet/private/enterprises/21239/geistV3/alarmSystem/alarmCfgTable/alarmCfgEntry/alarmCfgReadingID
  • Additional combinations skipped.

SNMP properties

Value type
OBJECT IDENTIFIER
Maximum access defined by MIB
read-create
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In GEIST-MIB-V3, the row index alarmCfgIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.21239.2.101.1.1.2.<alarmCfgIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.21239.2.101.1.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

alarmCfgReadingID OBJECT-TYPE
	SYNTAX  OBJECT IDENTIFIER
	MAX-ACCESS  read-create
	STATUS current
	DESCRIPTION 
		"OID of a particular measurement to monitor. This object
		is also used to create or delete a row. To create a new
		row, set the Sensor ID on a row that doesn't exist. Set
		the ReadingID to 0.0 to destroy a row."
	::= { alarmCfgEntry  2 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

OID of a particular measurement to monitor. This object is also used to create or delete a row. To create a new row, set the Sensor ID on a row that doesn\t exist. Set the ReadingID to 0.0 to destroy a row.
Original text from OID Repository
alarmCfgReadingID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"OID of a particular measurement to monitor. This object
is also used to create or delete a row. To create a new
row, set the Sensor ID on a row that doesn\t exist. Set
the ReadingID to 0.0 to destroy a row."
Sources for this description

OID Repository

View at oid-base.com

Description 2

OID of a particular measurement to monitor. This object is also used to create or delete a row. To create a new row, set the Sensor ID on a row that doesn't exist. Set the ReadingID to 0.0 to destroy a row.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

alarmCfgReadingID · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: alarmCfgReadingID

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "alarmCfgReadingID",
    "OBJECT-TYPE",
    "SYNTAX",
    "OBJECT",
    "IDENTIFIER",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"OID of a particular measurement to monitor. This object is also used to create or delete a row. To create a new row, set the Sensor ID on a row that doesn't exist. Set the ReadingID to 0.0 to destroy a row.\"",
    "::=",
    "{",
    "alarmCfgEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OBJECT IDENTIFIER",
      null
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "OID of a particular measurement to monitor. This object is also used to create or delete a row. To create a new row, set the Sensor ID on a row that doesn't exist. Set the ReadingID to 0.0 to destroy a row."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.21239)

Preuss Brad Wilson or Jesse

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.21239.2.101.1.1.1 alarmCfgIndex00 Table entry index value. Provides unique ID for alarm, numbered from 1 to 200
1.3.6.1.4.1.21239.2.101.1.1.3 alarmCfgThreshold00 Depending on TripSelect this value acts as an upper or lower boundary for the sensor value. The value is in units of tenths. SN…
1.3.6.1.4.1.21239.2.101.1.1.4 alarmCfgTripSelect00 Tells if alarm trips above or below the threshold value