Description 1
Analog Measurement Sensor (Voltage, Current, or Dry Contact)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21239.5.2.11
Analog Measurement Sensor (Voltage, Current, or Dry Contact)
Identification
{1 3 6 1 4 1 21239 5 2 11}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
a2dSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF A2DSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Analog Measurement Sensor (Voltage, Current, or Dry Contact)"
::= { imd 11 }a2dSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF A2dSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Analog measurement (A2D) sensor (voltage, current, or dry-contact)"
::= { imd 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Analog Measurement Sensor (Voltage, Current, or Dry Contact)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Analog measurement (A2D) sensor (voltage, current, or dry-contact)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: a2dSensorTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"a2dSensorTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"A2DSensorEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Analog Measurement Sensor (Voltage, Current, or Dry Contact)\"",
"::=",
"{",
"imd",
"11",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"A2DSensorEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Analog Measurement Sensor (Voltage, Current, or Dry Contact)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: GEIST-IMD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'IpAddress', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE']}Related source files and packages:
Status in source: current.
Names: a2dSensorTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"a2dSensorTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"A2dSensorEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Analog measurement (A2D) sensor (voltage, current, or dry-contact)\"",
"::=",
"{",
"imd",
"11",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"A2dSensorEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Analog measurement (A2D) sensor (voltage, current, or dry-contact)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: VERTIV-V5-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'MacAddress'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: VERTIV-V5-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'MacAddress'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Vendor MIB copy from the Observium Community archive.
Module: VERTIV-IMD-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21239.5.2.11.1 | a2dSensorEntry, a2DSensorEntry | 13 | 13 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21239.5.2.1 | deviceInfo | 15 | 15 | |
| 1.3.6.1.4.1.21239.5.2.3 | pdu | 7 | 94 | |
| 1.3.6.1.4.1.21239.5.2.4 | tempSensorTable | 1 | 6 | |
| 1.3.6.1.4.1.21239.5.2.5 | airFlowSensorTable | 1 | 9 | |
| 1.3.6.1.4.1.21239.5.2.6 | dewPointSensorTable | 1 | 8 | |
| 1.3.6.1.4.1.21239.5.2.7 | ccatSensorTable | 1 | 8 | |
| 1.3.6.1.4.1.21239.5.2.8 | t3hdSensorTable | 1 | 15 | |
| 1.3.6.1.4.1.21239.5.2.9 | thdSensorTable | 1 | 8 | |
| 1.3.6.1.4.1.21239.5.2.10 | rpmSensorTable | 1 | 16 | |
| 1.3.6.1.4.1.21239.5.2.12 | humiditySensorTable | 1 | 6 | |
| 1.3.6.1.4.1.21239.5.2.13 | sn2dSensorTable | 1 | 11 | |
| 1.3.6.1.4.1.21239.5.2.30 | cooling | 1 | 266 | |
| 1.3.6.1.4.1.21239.5.2.32767 | trap | 2 | 191 |