Description 1
PDU Phase Voltage (Min) in tenths of a volt
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21239.5.2.3.2.1.6
PDU Phase Voltage (Min) in tenths of a volt
Identification
{1 3 6 1 4 1 21239 5 2 3 2 1 6}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In VERTIV-IMD-MIB, the row index pduPhaseIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.21239.5.2.3.2.1.6.<pduPhaseIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.21239.5.2.3.2.1.6
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
pduPhaseVoltageMin OBJECT-TYPE
SYNTAX Gauge32
UNITS "decivolts (rms)"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PDU Phase Voltage (Min) in tenths of a volt"
::= { pduPhaseEntry 6 }pduPhaseVoltageMin OBJECT-TYPE
SYNTAX Gauge32(0..3100)
UNITS "decivolts (rms)"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest RMS voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt"
::= { pduPhaseEntry 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
PDU Phase Voltage (Min) in tenths of a volt
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Lowest RMS voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: pduPhaseVoltageMin
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pduPhaseVoltageMin",
"OBJECT-TYPE",
"SYNTAX",
"Gauge32",
"UNITS",
[
"literal",
"2264656369766f6c74732028726d732922"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"PDU Phase Voltage (Min) in tenths of a volt\"",
"::=",
"{",
"pduPhaseEntry",
"6",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge32"
],
[
"UNITS",
"decivolts (rms)"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"PDU Phase Voltage (Min) in tenths of a volt"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: GEIST-IMD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'IpAddress', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE']}Related source files and packages:
Status in source: current.
Names: pduPhaseVoltageMin
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pduPhaseVoltageMin",
"OBJECT-TYPE",
"SYNTAX",
"Gauge32",
"(",
"0",
".",
".",
"3100",
")",
"UNITS",
[
"literal",
"2264656369766f6c74732028726d732922"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Lowest RMS voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt\"",
"::=",
"{",
"pduPhaseEntry",
"6",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge32",
[
"integerSubType",
[
[
0,
3100
]
]
]
],
[
"UNITS",
"decivolts (rms)"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Lowest RMS voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: VERTIV-IMD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21239.5.2.3.2.1.1 | pduPhaseIndex | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.2 | pduPhaseName | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.3 | pduPhaseLabel | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.4 | pduPhaseVoltage | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.5 | pduPhaseVoltageMax | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.7 | pduPhaseVoltagePeak | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.8 | pduPhaseCurrent | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.9 | pduPhaseCurrentMax | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.10 | pduPhaseCurrentMin | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.11 | pduPhaseCurrentPeak | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.12 | pduPhaseRealPower | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.13 | pduPhaseApparentPower | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.14 | pduPhasePowerFactor | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.15 | pduPhaseEnergy | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.17 | pduPhaseBalance | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.19 | pduPhaseCurrentCrestFactor | 0 | 0 | |
| 1.3.6.1.4.1.21239.5.2.3.2.1.20 | pduPhaseResCurrentDetected | 0 | 0 |