Description 1
PDU Total Accumulated Energy Trap
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21239.5.2.32767.0.10312
PDU Total Accumulated Energy Trap
Identification
{1 3 6 1 4 1 21239 5 2 32767 0 10312}
Available source records contain 2 distinct definitions; some records may not include a definition.
pduTotalEnergyNOTIFY NOTIFICATION-TYPE
OBJECTS { pduTotalEnergy }
STATUS current
DESCRIPTION "PDU Total Accumulated Energy Trap"
::= { trapPrefix 10312 }pduTotalEnergyNOTIFY NOTIFICATION-TYPE
OBJECTS {
pduTotalEnergy,
trapThreshType,
trapSeverity,
sysName,
pduMainLabel,
pduTotalLabel
}
STATUS current
DESCRIPTION "PDU total energy trap"
::= { trapPrefix 10312 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
PDU Total Accumulated Energy Trap
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
PDU total energy trap
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: pduTotalEnergyNOTIFY
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"pduTotalEnergyNOTIFY",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"pduTotalEnergy",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"PDU Total Accumulated Energy Trap\"",
"::=",
"{",
"trapPrefix",
"10312",
"}"
],
"syntax_tree": [
[
"Objects",
[
"pduTotalEnergy"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"PDU Total Accumulated Energy Trap"
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: GEIST-IMD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'IpAddress', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE']}Related source files and packages:
Status in source: current.
Names: pduTotalEnergyNOTIFY
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"pduTotalEnergyNOTIFY",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"pduTotalEnergy",
",",
"trapThreshType",
",",
"trapSeverity",
",",
"sysName",
",",
"pduMainLabel",
",",
"pduTotalLabel",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"PDU total energy trap\"",
"::=",
"{",
"trapPrefix",
"10312",
"}"
],
"syntax_tree": [
[
"Objects",
[
"pduTotalEnergy",
"trapThreshType",
"trapSeverity",
"sysName",
"pduMainLabel",
"pduTotalLabel"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"PDU total energy trap"
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: VERTIV-V5-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'MacAddress'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: VERTIV-V5-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'MacAddress'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Vendor MIB copy from the Observium Community archive.
Module: VERTIV-IMD-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'enterprises', 'Integer32', 'Gauge32', 'NOTIFICATION-TYPE'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Registration