ATEN PE MIB
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21317.1.3.2.3
ATEN PE MIB
Identification
{1 3 6 1 4 1 21317 1 3 2 3}
Available source records contain 2 distinct definitions; some records may not include a definition.
pe2 OBJECT IDENTIFIER ::= { poweroverip 3 }pe2 MODULE-IDENTITY
LAST-UPDATED "201801231200Z"
ORGANIZATION "ATEN"
CONTACT-INFO "Aten, Inc."
DESCRIPTION "ATEN PE MIB"
REVISION "201801231200Z"
DESCRIPTION "support stations"
::= { poweroverip 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
ATEN PE MIB
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: pe2
{
"smi_kind": "OBJECT IDENTIFIER",
"definition": [
"pe2",
"OBJECT",
"IDENTIFIER",
"::=",
"{",
"poweroverip",
"3",
"}"
]
}Vendor MIB copy from the Observium Community archive.
Module: ATEN-PRODUCTS-MIB
See published definition above
{'ATEN-SMI': ['atenProducts']}Related source files and packages:
Status in source: unspecified.
Names: pe2
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"pe2",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313830313233313230305a22"
],
"ORGANIZATION",
"\"ATEN\"",
"CONTACT-INFO",
"\"Aten, Inc.\"",
"DESCRIPTION",
"\"ATEN PE MIB\"",
"REVISION",
[
"literal",
"223230313830313233313230305a22"
],
"DESCRIPTION",
"\"support stations\"",
"::=",
"{",
"poweroverip",
"3",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201801231200Z"
],
[
"ORGANIZATION",
"ATEN"
],
[
"CONTACT-INFO",
"Aten, Inc."
],
[
"DESCRIPTION",
"ATEN PE MIB"
],
[
"Revisions",
[
[
"201801231200Z",
[
"DESCRIPTION",
"support stations"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: ATEN-PE2-CFG
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber'], 'ATEN-PRODUCTS-MIB': ['poweroverip'], 'SNMP-USER-BASED-SM-MIB': ['KeyChange']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21317.1.3.2.3.1 | management | 5 | 22 | |
| 1.3.6.1.4.1.21317.1.3.2.3.2 | energy | 5 | 155 | |
| 1.3.6.1.4.1.21317.1.3.2.3.3 | environment | 2 | 24 | |
| 1.3.6.1.4.1.21317.1.3.2.3.4 | network | 3 | 18 | |
| 1.3.6.1.4.1.21317.1.3.2.3.5 | event | 1 | 19 | |
| 1.3.6.1.4.1.21317.1.3.2.3.50 | trapNotification | 3 | 11 | |
| 1.3.6.1.4.1.21317.1.3.2.3.150 | deviceLock | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21317.1.3.2.1 | pn9108 | 0 | 0 | |
| 1.3.6.1.4.1.21317.1.3.2.2 | pe | 6 | 368 | |
| 1.3.6.1.4.1.21317.1.3.2.30 | pn7320-7212-5320-5212 | 0 | 0 | |
| 1.3.6.1.4.1.21317.1.3.2.35 | pn5101 | 0 | 0 |