event description
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21728.4.9.0.13
event description
Identification
{1 3 6 1 4 1 21728 4 9 0 13}
The displayed source records contain one distinct definition. Compare its source records.
inletLineFrequencyMinThreshold NOTIFICATION-TYPE
OBJECTS {
deviceName,
deviceIpAddress,
inletLineFrequency,
inletName,
inletPlug,
inletType,
inletLineConfiguration,
eventType,
eventCode,
eventName,
eventTriggerAttr1,
eventTriggerAttr2,
eventTriggerAttr3
}
STATUS current
DESCRIPTION
"event description"
::= { eventTraps 13 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
event description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: inletLineFrequencyMinThreshold
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"inletLineFrequencyMinThreshold",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"deviceName",
",",
"deviceIpAddress",
",",
"inletLineFrequency",
",",
"inletName",
",",
"inletPlug",
",",
"inletType",
",",
"inletLineConfiguration",
",",
"eventType",
",",
"eventCode",
",",
"eventName",
",",
"eventTriggerAttr1",
",",
"eventTriggerAttr2",
",",
"eventTriggerAttr3",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"event description\"",
"::=",
"{",
"eventTraps",
"13",
"}"
],
"syntax_tree": [
[
"Objects",
[
"deviceName",
"deviceIpAddress",
"inletLineFrequency",
"inletName",
"inletPlug",
"inletType",
"inletLineConfiguration",
"eventType",
"eventCode",
"eventName",
"eventTriggerAttr1",
"eventTriggerAttr2",
"eventTriggerAttr3"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"event description"
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SYNLINK-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Integer32', 'NOTIFICATION-TYPE', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21728.4.9.0.1 | autopingTimeout | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.2 | line1CurrentMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.3 | line2CurrentMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.4 | line3CurrentMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.5 | line1CurrentMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.6 | line2CurrentMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.7 | line3CurrentMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.8 | inletCurrentMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.9 | inletCurrentMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.10 | inletVoltageMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.11 | inletVoltageMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.12 | inletLineFrequencyMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.14 | inletPowerFactorMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.15 | inletActiveEnergyMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.16 | inletActivePowerMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.17 | inletActivePowerMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.18 | inletApparentPowerMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.19 | inletApparentPowerMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.20 | inletReactivePowerMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.21 | inletReactivePowerMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.22 | inlet3phaseImbalance | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.23 | bankBreakerTrip | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.24 | bankCurrentMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.25 | bankCurrentMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.26 | bankVoltageMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.27 | bankVoltageMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.28 | bankLineFrequencyMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.29 | bankLineFrequencyMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.30 | bankPowerfactorMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.32 | bankActivePowerMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.33 | bankActivePowerMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.34 | bankApparentPowerMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.35 | bankApparentPowerMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.36 | bankReactivePowerMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.37 | bankReactivePowerMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.38 | outletCurrentMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.39 | outletCurrentMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.42 | temperatureMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.43 | temperatureMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.44 | humidityMaxThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.45 | humidityMinThreshold | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.46 | scheduledTime | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.47 | scheduledInterval | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.48 | atsInletSwitchedToSecondary | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.49 | atsInletSwitchedToPrimary | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.50 | atsInletSecondaryPowerLoss | 0 | 0 | |
| 1.3.6.1.4.1.21728.4.9.0.51 | atsInletSecondaryPowerRestored | 0 | 0 |