An entry containing information applicable to a particular binary input.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21796.5.1.4.1
An entry containing information applicable to a particular binary input.
Identification
{1 3 6 1 4 1 21796 5 1 4 1}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
conditionEntry OBJECT-TYPE
SYNTAX ConditionEntry
ACCESS not-accessible
STATUS mandatory
INDEX { meterID, varID, conditionID }
::= { conditionTable 1 }inpEntry OBJECT-TYPE
SYNTAX InpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a particular binary input."
INDEX { inpIndex }
::= { inpTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
An entry containing information applicable to a particular binary input.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: conditionEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"conditionEntry",
"OBJECT-TYPE",
"SYNTAX",
"ConditionEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"INDEX",
"{",
"meterID",
",",
"varID",
",",
"conditionID",
"}",
"::=",
"{",
"conditionTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"ConditionEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
null,
null,
null,
[
"INDEX",
[
[
0,
"meterID"
],
[
0,
"varID"
],
[
0,
"conditionID"
]
]
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: Perseus-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'TimeTicks'], 'RFC1213-MIB': ['sysName']}Related source files and packages:
Status in source: mandatory.
Names: inpEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"inpEntry",
"OBJECT-TYPE",
"SYNTAX",
"InpEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"An entry containing information applicable to a particular binary input.\"",
"INDEX",
"{",
"inpIndex",
"}",
"::=",
"{",
"inpTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"InpEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"An entry containing information applicable to a particular binary input."
],
null,
null,
[
"INDEX",
[
[
0,
"inpIndex"
]
]
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SD-PORTAL-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21796.5.1.4.1.1 | conditionID, inpIndex | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.2 | conditionName, inpId | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.3 | conditionState, inpName | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.4 | conditionEnable, inpAlias | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.5 | conditionTextID, inpValue | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.6 | conditionMin, inpState | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.7 | conditionMax, inpAlarmSetup | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.8 | conditionHyst, inpDescription | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.9 | conditionDelay, inpDevId | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.10 | inpDelay | 0 | 0 | |
| 1.3.6.1.4.1.21796.5.1.4.1.11 | inpLastRead | 0 | 0 |