Description 1
Original text from OID Repository
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Channel 1 temperature low alarm limit."
OID reference
1.3.6.1.4.1.22626.1.5.2.1.6
Channel 1 temperature low alarm limit.
Identification
{1 3 6 1 4 1 22626 1 5 2 1 6}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.22626.1.5.2.1.6.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ch1LimLo OBJECT-TYPE
SYNTAX INTEGER (-550..1250)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Channel 1 low alarm limit (value * 10)"
::= { channel1 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Description 2
Channel 1 low alarm limit (value * 10)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: ch1LimLo
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ch1LimLo",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"550",
".",
".",
"1250",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Channel 1 low alarm limit (value * 10)\"",
"::=",
"{",
"channel1",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-550,
1250
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Channel 1 low alarm limit (value * 10)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: P8541-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Vendor MIB copy from the Observium Community archive.
Module: P8641-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.22626.1.5.2.1.1 | ch1Name | 0 | 0 | Channel 1 name. |
| 1.3.6.1.4.1.22626.1.5.2.1.2 | ch1Val | 0 | 0 | Channel 1 temperature. |
| 1.3.6.1.4.1.22626.1.5.2.1.3 | ch1IntVal | 0 | 0 | Channel 1 temperature * 10 (12,5 dgr C = 125). |
| 1.3.6.1.4.1.22626.1.5.2.1.4 | ch1Alarm | 0 | 0 | Alarm on channel 1; 0 - No alarm, 1 - Alarm Hi, 2- Alarm Lo. |
| 1.3.6.1.4.1.22626.1.5.2.1.5 | ch1LimHi | 0 | 0 | Channel 1 temperature upper alarm limit. |
| 1.3.6.1.4.1.22626.1.5.2.1.7 | ch1LimHyst | 0 | 0 | Channel 1 temperature hysteressis. |
| 1.3.6.1.4.1.22626.1.5.2.1.8 | ch1Delay, ch1LimDelay | 0 | 0 | Channel 1 temperature alarm delay [s]. |
| 1.3.6.1.4.1.22626.1.5.2.1.9 | ch1Unit | 0 | 0 | |
| 1.3.6.1.4.1.22626.1.5.2.1.10 | ch1AlarmStr | 0 | 0 | |
| 1.3.6.1.4.1.22626.1.5.2.1.11 | ch1Min | 0 | 0 | |
| 1.3.6.1.4.1.22626.1.5.2.1.12 | ch1Max | 0 | 0 |