A collection of objects used to request topology configuration changes.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.22764.1.1.4.2.4
A collection of objects used to request topology configuration changes.
Identification
{1 3 6 1 4 1 22764 1 1 4 2 4}
The displayed source records contain one distinct definition. Compare its source records.
inputTopologyGroup OBJECT-GROUP
OBJECTS { plcModulationInputAddr, plcModulationInputChannel, plcModulationInputBand,
plcInputModulationGroup1, plcInputModulationGroup2,
plcInputModulationGroup3, plcInputModulationGroup4,
plcInputModulationGroup5, plcInputModulationGroup6,
plcInputModulationGroup7, plcInputModulationGroup8,
plcInputModulationGroup9, plcInputModulationGroup10,
plcInputModulationGroup11, plcInputModulationGroup12,
plcInputModulationGroup13, plcInputModulationGroup14,
plcInputModulationGroup15, plcInputModulationGroup16,
plcModulationInputProceed, plcModulationInputResult,
plcPilotsInputAddr, plcPilotsInputChannel, plcPilotsInputBand,
plcInputChannelPilot1, plcInputChannelPilot2,
plcPilotsInputProceed, plcPilotsInputResult }
STATUS current
DESCRIPTION "A collection of objects used to request
topology configuration changes."
::= { plcGroups 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A collection of objects used to request topology configuration changes.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: inputTopologyGroup
{
"smi_kind": "OBJECT-GROUP",
"definition": [
"inputTopologyGroup",
"OBJECT-GROUP",
"OBJECTS",
"{",
"plcModulationInputAddr",
",",
"plcModulationInputChannel",
",",
"plcModulationInputBand",
",",
"plcInputModulationGroup1",
",",
"plcInputModulationGroup2",
",",
"plcInputModulationGroup3",
",",
"plcInputModulationGroup4",
",",
"plcInputModulationGroup5",
",",
"plcInputModulationGroup6",
",",
"plcInputModulationGroup7",
",",
"plcInputModulationGroup8",
",",
"plcInputModulationGroup9",
",",
"plcInputModulationGroup10",
",",
"plcInputModulationGroup11",
",",
"plcInputModulationGroup12",
",",
"plcInputModulationGroup13",
",",
"plcInputModulationGroup14",
",",
"plcInputModulationGroup15",
",",
"plcInputModulationGroup16",
",",
"plcModulationInputProceed",
",",
"plcModulationInputResult",
",",
"plcPilotsInputAddr",
",",
"plcPilotsInputChannel",
",",
"plcPilotsInputBand",
",",
"plcInputChannelPilot1",
",",
"plcInputChannelPilot2",
",",
"plcPilotsInputProceed",
",",
"plcPilotsInputResult",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A collection of objects used to request topology configuration changes.\"",
"::=",
"{",
"plcGroups",
"4",
"}"
],
"syntax_tree": [
[
"Objects",
[
"plcModulationInputAddr",
"plcModulationInputChannel",
"plcModulationInputBand",
"plcInputModulationGroup1",
"plcInputModulationGroup2",
"plcInputModulationGroup3",
"plcInputModulationGroup4",
"plcInputModulationGroup5",
"plcInputModulationGroup6",
"plcInputModulationGroup7",
"plcInputModulationGroup8",
"plcInputModulationGroup9",
"plcInputModulationGroup10",
"plcInputModulationGroup11",
"plcInputModulationGroup12",
"plcInputModulationGroup13",
"plcInputModulationGroup14",
"plcInputModulationGroup15",
"plcInputModulationGroup16",
"plcModulationInputProceed",
"plcModulationInputResult",
"plcPilotsInputAddr",
"plcPilotsInputChannel",
"plcPilotsInputBand",
"plcInputChannelPilot1",
"plcInputChannelPilot2",
"plcPilotsInputProceed",
"plcPilotsInputResult"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A collection of objects used to request topology configuration changes."
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SPC200
See published definition above
{'IF-MIB': ['interfaces', 'ifIndex'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'MacAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'IpAddress', 'Unsigned32', 'Gauge32'], 'SNMPv2-CONF': ['AGENT-CAPABILITIES', 'OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'SPIDCOM-MIB': ['spidcom']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SPC200
{'IF-MIB': ['interfaces', 'ifIndex'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'MacAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'IpAddress', 'Unsigned32', 'Gauge32'], 'SNMPv2-CONF': ['AGENT-CAPABILITIES', 'OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'SPIDCOM-MIB': ['spidcom']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.22764.1.1.4.2.1 | nodeGroup | 0 | 0 | |
| 1.3.6.1.4.1.22764.1.1.4.2.2 | inputNodeGroup | 0 | 0 | |
| 1.3.6.1.4.1.22764.1.1.4.2.3 | topologyGroup | 0 | 0 | |
| 1.3.6.1.4.1.22764.1.1.4.2.5 | statisticGroup | 0 | 0 | |
| 1.3.6.1.4.1.22764.1.1.4.2.6 | softwareGroup | 0 | 0 | |
| 1.3.6.1.4.1.22764.1.1.4.2.7 | analyserGroup | 0 | 0 |