bootWatchdogTime — Fujitsu / Siemens native MIB archives
Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
{1 3 6 1 4 1 231 2 10 2 2 5 3 13}
Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status in source: mandatory.
Names: bootWatchdogTime
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"bootWatchdogTime",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"1",
".",
".",
"120",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.\"",
"::=",
"{",
"errorHandling",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
1,
120
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'."
],
null,
null,
null,
null
]
}Vendor MIB copy from the MibBrowser.online archive. Fujitsu support.
Module: SNI-SERVER-CONTROL-MIB
bootWatchdogTime OBJECT-TYPE
SYNTAX INTEGER(1..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Timeout time of the boot watchdog (in minutes, -1 = unknown).
The value unknown(-1) cannot be set, a SET will deliver 'badValue'."
::= { errorHandling 13 }{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter', 'Gauge', 'IpAddress'], 'RFC1213-MIB': ['mib-2']}Related source files and packages:
Published package: Fujitsu archived MIB undated archived revision; file: SNI-SERVER-CONTROL-MIB.mib.
Downloaded: 2026-10-27T05:15:12.421194+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.231.2.10.2.2.5.3.1 | eventLogTable | 1 | 3 | Table with event log entries (can also contain critical errors when an ErrorLog for critical errors is not available) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.2 | eventLogMaxEntries | 1 | 1 | Number of EventLog entries (can be used to directly get all table entries with one varbind list) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.3 | errorLogTable | 1 | 3 | Table with critial error log entries (can be missing on some hardware platforms) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.4 | errorLogMaxEntries | 1 | 1 | Number of ErrorLog entries (can be used to directly get all table entries with one varbind list) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.5 | hardwareWatchdogStatus | 1 | 1 | Status of the hardware watchdog (periodically restarted by the server management BIOS). The hardware watchdog is only supported o… |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.6 | hardwareWatchdogTime | 1 | 1 | Timeout time of the hardware watchdog (in seconds, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.7 | hardwareWatchdogEnable | 1 | 1 | Enable/disable the hardware watchdog. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.8 | softwareWatchdogStatus | 1 | 1 | Status of the software watchdog (periodically restarted by the server management agent) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.9 | softwareWatchdogTime | 1 | 1 | Timeout time of the software watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badVa… |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.10 | softwareWatchdogEnable | 1 | 1 | Enable/disable the software watchdog |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.11 | softwareWatchdogAction | 1 | 1 | Action when the software watchdog timeout occurs (shutdown and reboot, continue...). The value unknown(1) cannot be set, a SET w… |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.12 | bootWatchdogStatus | 0 | 0 | |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.14 | bootWatchdogEnable | 0 | 0 | |