This parameter control the downstream line monitoring for CPE's which do not support the nearest supported impulse noise protection (INP) value. This is related to MIB-parameter checks for ADSL2x links between CO side and CPE side. In particular it can be checked whether a configured (i.e. desired) parameter setting is supported by the attached CPE as well. This capability information is exchange during handshake phase. When activated, the consequence of parameter violation can be to generate just a alarm and go to showtime anyway or the CPE shall not synchronize at all, i.e. the link will not be established. Valid settings: checkMinINP(1) -> set BIT to 1 will enable the MinINP check abortOnINPViolation(2) -> set BIT to 1 will abort the trainings sequence and the line will not reach showtime state if a INP config violation was detectedcted Note: New parameter with R2.8 maintenance. It is DSL firmware depended if a line support this feature and if a separate abort-handling is possible. If no support is available, the configuration will be ignored.
OID reference
sheXdslLineAlarmConfigViolationCheck
1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.15
Description
This parameter control the downstream line monitoring for CPE's which do not support the nearest supported impulse noise protection (INP) value. This is related to MIB-parameter checks for ADSL2x links between CO side and CPE side. In particular it can be checked whether a configured (i.e. desired) parameter setting i…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1 (sheXdslLineAlarmConfProfileEntry)
- Node code
- 15
- Node name
- sheXdslLineAlarmConfigViolationCheck
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.15
- URN notation
- urn:oid:1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.15
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 231 7 1 2 2 1 14 1 1 13 1 15}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheXdslMib(14) sheXdslLineMib(1) sheXdslMibObjects(1) sheXdslLineAlarmConfProfileTable(13) sheXdslLineAlarmConfProfileEntry(1) sheXdslLineAlarmConfigViolationCheck(15)}
- OID-IRI notation
- /1/3/6/1/4/1/231/7/1/2/2/1/14/1/1/13/1/15
- /ISO/Identified-Organization/6/1/4/1/231/7/1/2/2/1/14/1/1/13/1/15
- /ISO/3/6/1/4/1/231/7/1/2/2/1/14/1/1/13/1/15
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/identified-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/identified-organization/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/identified-organization/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/org/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/org/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/org/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/org/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-identified-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-identified-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-identified-organization/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-organization/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
- /iso/iso-organization/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheXdslMib/sheXdslLineMib/sheXdslMibObjects/sheXdslLineAlarmConfProfileTable/sheXdslLineAlarmConfProfileEntry/sheXdslLineAlarmConfigViolationCheck
SNMP properties
- Value type
- SheXdslConfigViolationCheckType
- Maximum access defined by MIB
- read-only
- Status in MIB
- current
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
sheXdslLineAlarmConfigViolationCheck OBJECT-TYPE
SYNTAX SheXdslConfigViolationCheckType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter control the downstream line monitoring for CPE's which do not support the nearest
supported impulse noise protection (INP) value. This is related to MIB-parameter checks for
ADSL2x links between CO side and CPE side. In particular it can be checked whether a configured
(i.e. desired) parameter setting is supported by the attached CPE as well.
This capability information is exchange during handshake phase.
When activated, the consequence of parameter violation can be to generate just a alarm and
go to showtime anyway or the CPE shall not synchronize at all, i.e. the link will not be established.
Valid settings:
checkMinINP(1) -> set BIT to 1 will enable the MinINP check
abortOnINPViolation(2) -> set BIT to 1 will abort the trainings sequence and the line will not reach
showtime state if a INP config violation was detectedcted
Note:
New parameter with R2.8 maintenance.
It is DSL firmware depended if a line support this feature and if a separate abort-handling
is possible. If no support is available, the configuration will be ignored."
::= { sheXdslLineAlarmConfProfileEntry 15 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; representative source files are shown for each definition.
Records for description 1Fujitsu / Siemens native MIB archives
sheXdslLineAlarmConfigViolationCheck · currentFujitsu / Siemens native MIB archives
Status in source: current.
Names: sheXdslLineAlarmConfigViolationCheck
- Fujitsu / Siemens native MIB archives
· Publisher's source file: SHE-XDSL-MIB — archive MIB indexed for Fujitsu
Vendor MIB copy from the MibBrowser.online archive. Fujitsu support.
Module: SHE-XDSL-MIB
See published definition above
Source data warning: The archive provides an older AN-MIB that does not define she. A separately retained Nokia Siemens Networks AN-MIB, generated on 23 February 2009 from the she_main_grf branch, explicitly defines she as 1.3.6.1.4.1.231.7.1.2.2.1. These rows are a qualified interpretation using that dependency edition. Compatibility with the child file release and actual device OIDs is unconfirmed; do not treat this as a verified device mapping. Published names, definitions and numeric suffixes are preserved. Consult both downloadable native files.
· Download SHE-XDSL-MIB — archive MIB indexed for FujitsuRelated source files and packages:
- AN-MIB — archive MIB indexed for Fujitsu
- HC-PerfHist-TC-MIB — dependency MIB (MibBrowser.online)
- IF-MIB — dependency MIB (MibBrowser.online)
More related source documents
- SHE-ALARMING-MIB — archive MIB indexed for Fujitsu
- SHE-TC-MIB — archive MIB indexed for Fujitsu
- SNMP-FRAMEWORK-MIB — dependency MIB (MibBrowser.online)
- SNMPv2-CONF — dependency MIB (MibBrowser.online)
- SNMPv2-SMI — dependency MIB (MibBrowser.online)
- SNMPv2-TC — dependency MIB (MibBrowser.online)
- AN-MIB — native namespace for she
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.231)
Siblings (11)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.1 | sheXdslLineAlarmConfProfileIndex | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.2 | sheXdslLineAlarmConfProfileName | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.3 | sheXdslThresh15MinLofs | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.4 | sheXdslThresh15MinLoss | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.5 | sheXdslThresh15MinLprs | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.6 | sheXdslThresh15MinLols | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.7 | sheXdslThresh15MinESs | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.8 | sheXdslThresh15MinSESs | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.9 | sheXdslThresh15MinUASs | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.10 | sheXdslInitFailureNotifyEnable | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.14.1.1.13.1.13 | sheXdslLineAlarmOperationalStateNotifyEnable | 0 | 0 |