This parameter defines the configured reference or assigned SSM-Level for this sync source. It should work as reference level only for source types, which supports SSM OAM messages for clock quality evaluation like ToP or syncEthernet. For other sourcetypes it is the assigned SSM-Level which should be used by the input selector for sourceclock quality comparation. The level is defined in 16 steps from 0..15, where 0 is the highest quality level. The sync source will be invalid, if the received SSM level is above the configured reference level. New parameter with R2.8.
OID reference
sheSyncSourceSSMLevel
1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.8
Description
This parameter defines the configured reference or assigned SSM-Level for this sync source. It should work as reference level only for source types, which supports SSM OAM messages for clock quality evaluation like ToP or syncEthernet. For other sourcetypes it is the assigned SSM-Level which should be used by the inpu…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1 (sheSyncSourceEntry)
- Node code
- 8
- Node name
- sheSyncSourceSSMLevel
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.8
- URN notation
- urn:oid:1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.8
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 231 7 1 2 2 1 15 1 2 1 8}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) ppe(2) she(1) sheSync(15) sheSyncObjects(1) sheSyncSourceTable(2) sheSyncSourceEntry(1) sheSyncSourceSSMLevel(8)}
- OID-IRI notation
- /1/3/6/1/4/1/231/7/1/2/2/1/15/1/2/1/8
- /ISO/Identified-Organization/6/1/4/1/231/7/1/2/2/1/15/1/2/1/8
- /ISO/3/6/1/4/1/231/7/1/2/2/1/15/1/2/1/8
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/identified-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/identified-organization/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/identified-organization/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/org/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/org/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/org/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/org/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-identified-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-identified-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-identified-organization/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-organization/dod/internet/private/ldap-enterprise/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
- /iso/iso-organization/dod/internet/private/vendor-objects/sni/siemensUnits/oenProductMibs/an/ppe/she/sheSync/sheSyncObjects/sheSyncSourceTable/sheSyncSourceEntry/sheSyncSourceSSMLevel
SNMP properties
- Value type
- Unsigned32
- Maximum access defined by MIB
- read-only
- Status in MIB
- current
- Allowed ranges
- 0–15
Using this OID with SNMP
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: sheSyncSourcePriority.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.8
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
sheSyncSourceSSMLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines the configured reference or assigned SSM-Level for this sync source.
It should work as reference level only for source types, which supports SSM OAM messages for
clock quality evaluation like ToP or syncEthernet.
For other sourcetypes it is the assigned SSM-Level which should be used by the input selector
for sourceclock quality comparation.
The level is defined in 16 steps from 0..15, where 0 is the highest quality level.
The sync source will be invalid, if the received SSM level is above the configured
reference level.
New parameter with R2.8."
::= { sheSyncSourceEntry 8 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; representative source files are shown for each definition.
Records for description 1Fujitsu / Siemens native MIB archives
sheSyncSourceSSMLevel · currentFujitsu / Siemens native MIB archives
Status in source: current.
Names: sheSyncSourceSSMLevel
- Fujitsu / Siemens native MIB archives
· Publisher's source file: SHE-SYNC-MIB — archive MIB indexed for Fujitsu
Vendor MIB copy from the MibBrowser.online archive. Fujitsu support.
Module: SHE-SYNC-MIB
See published definition above
Source data warning: The archive provides an older AN-MIB that does not define she. A separately retained Nokia Siemens Networks AN-MIB, generated on 23 February 2009 from the she_main_grf branch, explicitly defines she as 1.3.6.1.4.1.231.7.1.2.2.1. These rows are a qualified interpretation using that dependency edition. Compatibility with the child file release and actual device OIDs is unconfirmed; do not treat this as a verified device mapping. Published names, definitions and numeric suffixes are preserved. Consult both downloadable native files.
· Download SHE-SYNC-MIB — archive MIB indexed for FujitsuRelated source files and packages:
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.231)
Siblings (8)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.1 | sheSyncSourcePriority | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.2 | sheSyncSourceType | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.3 | sheSyncSourceHwUnitIndex | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.4 | sheSyncSourceInterfaceNumber | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.5 | sheSyncSourceAlarmState | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.6 | sheSyncSourceAlarmSeverityIndex | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.7 | sheSyncSourceSelectedAvailabilityIndex | 0 | 0 | |
| 1.3.6.1.4.1.231.7.1.2.2.1.15.1.2.1.9 | sheSyncSourceSSMLevelRec | 0 | 0 |