Reference record for OID 1.3.6.1.4.1.232.0.1002

Parent
1.3.6.1.4.1.232.0 (0)
Node code
1002
Node name
cpqSePCCardThermalDegraded
Numeric OID
1.3.6.1.4.1.232.0.1002
URN notation
urn:oid:1.3.6.1.4.1.232.0.1002
ASN.1 notation

{1 3 6 1 4 1 232 0 1002}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/1002
  • /ISO/Identified-Organization/6/1/4/1/232/0/1002
  • /ISO/3/6/1/4/1/232/0/1002
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSePCCardThermalDegraded
  • Additional combinations skipped.

Descriptions

cpqSePCCardThermalDegraded — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal Degraded (2). The manufacturer and product information strings as well as the slot number for the degraded PC Card is provided as parameters for this trap.

Source records

cpqSePCCardThermalDegraded

Status in source: unspecified.

Names: cpqSePCCardThermalDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSePCCardThermalDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSePCCardDeviceInfo",
    ",",
    "cpqSePCCardProductInfo",
    ",",
    "cpqSePCCardSlotIndex",
    "}",
    "DESCRIPTION",
    "\"This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal Degraded (2). The manufacturer and product information strings as well as the slot number for the degraded PC Card is provided as parameters for this trap.\"",
    "::=",
    "1002"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSePCCardDeviceInfo",
        "cpqSePCCardProductInfo",
        "cpqSePCCardSlotIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal Degraded (2). The manufacturer and product information strings as well as the slot number for the degraded PC Card is provided as parameters for this trap."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.814410+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.793162+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ1.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.793822+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo, 
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex } 
            DESCRIPTION 
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been 
                exceeded for safe operations thereby causing degraded operations. This trap 
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal 
                Degraded (2). 
                The manufacturer and product information strings as well as the slot number 
                for the degraded PC Card is provided as parameters for this trap." 
            --#TYPE "PC Card Thermal Degraded Status" 
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded." 
            --#ARGUMENTS {4} 
            --#SEVERITY MAJOR 
            --#TIMEINDEX 99 
            --#STATE DEGRADED 
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-StdEquipment.mib.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.810949+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqStdEquipment.mib.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.854099+00:00.

  • Preserved circitor archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB.mib
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.802860+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSTDEQ-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC card %d thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    		--#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY THERMAL        
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB

    Related source files and packages:


    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.148420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC card %d thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY THERMAL
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB

    Related source files and packages:


    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.262276+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22080 cpqRackMinorWSMANTrap00
1.3.6.1.4.1.232.0.22081 cpqRackMajorWSMANTrap00
1.3.6.1.4.1.232.0.22082 cpqRackCriticalWSMANTrap00
1.3.6.1.4.1.232.0.22083 cpqRackEnclosureManagerLinkDown00
1.3.6.1.4.1.232.0.22084 cpqRackEnclosureManagerLinkUp00
1.3.6.1.4.1.232.0.22085 cpqRackErsCommFailure00
1.3.6.1.4.1.232.0.22086 cpqRackPowerSubsystemOverloadConditionRepaired00
1.3.6.1.4.1.232.0.22087 cpqRackPowerSubsystemRedundancyOk00
1.3.6.1.4.1.232.0.22088 cpqRackNetConnectorTempDegraded00
1.3.6.1.4.1.232.0.22089 cpqRackNetConnectorTempOk00
1.3.6.1.4.1.232.0.22090 cpqRackEnvironmentalLeakDetected00
1.3.6.1.4.1.232.0.22091 cpqRackEnvironmentalDoorState00
1.3.6.1.4.1.232.0.22092 cpqRackEnvironmentalAirTempSensor00
1.3.6.1.4.1.232.0.22093 cpqRackEnvironmentalControlValveStatus00
1.3.6.1.4.1.232.0.22094 cpqRackEnvironmentalWaterTempThresholdExceeded00
1.3.6.1.4.1.232.0.22095 cpqRackEnvironmentalFlowSensorStatus00
1.3.6.1.4.1.232.0.22096 cpqRackEnvironmentalWaterPressureThresholdExceeded00
1.3.6.1.4.1.232.0.22097 cpqRackEnvironmentalAutomaticRapidPowerOff00
1.3.6.1.4.1.232.0.22098 cpqRackEnvironmentalRopeLeakDetectorEvent00
1.3.6.1.4.1.232.0.22099 cpqRackEnvironmentalTemperatureThresholdExceeded00
1.3.6.1.4.1.232.0.22100 cpqRackEnvironmentalHumidityThresholdExceeded00
1.3.6.1.4.1.232.0.22101 cpqRackEnvironmentalControllerOnBoardBattery00
1.3.6.1.4.1.232.0.22102 cpqRackEnvironmentalControllerAPMCommunicationFailure00
1.3.6.1.4.1.232.0.22103 cpqRackEnvironmentalLeakDetectedCritical00
1.3.6.1.4.1.232.0.22104 cpqRackPowerSubsystemReductionModeActivate00
1.3.6.1.4.1.232.0.22105 cpqRackPowerSubsystemReductionModeDeactivate00
1.3.6.1.4.1.232.0.23001 cpqNodeTemperatureDegraded00
1.3.6.1.4.1.232.0.23002 cpqNodeTemperatureOk00
1.3.6.1.4.1.232.0.23003 cpqNodeTemperatureFailed00
1.3.6.1.4.1.232.0.23004 cpqNodeErrorEvent00
1.3.6.1.4.1.232.0.23010 cpqNodePowerOn00
1.3.6.1.4.1.232.0.23011 cpqNodePowerOff00
1.3.6.1.4.1.232.0.99999 cpqGenericUnregistered00
1.3.6.1.4.1.232.0.136001 emuEventTrapInformative00
1.3.6.1.4.1.232.0.136002 emuEventTrapNoncritical00
1.3.6.1.4.1.232.0.136003 emuEventTrapCritical00
1.3.6.1.4.1.232.0.136004 emuEventTrapUnrecoverable00
1.3.6.1.4.1.232.0.140001 cpqICAAdd00
1.3.6.1.4.1.232.0.140002 cpqICADelete00
1.3.6.1.4.1.232.0.140003 cpqICAPropertyChange00
1.3.6.1.4.1.232.0.140004 cpqICAMove00
1.3.6.1.4.1.232.0.140005 cpqICAImportRestoreStart00
1.3.6.1.4.1.232.0.140006 cpqICAImportRestoreEnd00
1.3.6.1.4.1.232.0.150001 cpqDMIIndicationInfo00
1.3.6.1.4.1.232.0.150002 cpqDMIIndicationMonitor00
1.3.6.1.4.1.232.0.150003 cpqDMIIndicationOK00
1.3.6.1.4.1.232.0.150004 cpqDMIIndicationNonCritical00
1.3.6.1.4.1.232.0.150005 cpqDMIIndicationCritical00
1.3.6.1.4.1.232.0.150006 cpqDMIIndicationNonNonRecoverable00
1.3.6.1.4.1.232.0.161001 switchFirmwareTransferred00