Reference record for OID 1.3.6.1.4.1.232.0.1002

Parent
1.3.6.1.4.1.232.0 (0)
Node code
1002
Node name
cpqSePCCardThermalDegraded
Numeric OID
1.3.6.1.4.1.232.0.1002
URN notation
urn:oid:1.3.6.1.4.1.232.0.1002
ASN.1 notation

{1 3 6 1 4 1 232 0 1002}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSePCCardThermalDegraded(1002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSePCCardThermalDegraded(1002)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/1002
  • /ISO/Identified-Organization/6/1/4/1/232/0/1002
  • /ISO/3/6/1/4/1/232/0/1002
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSePCCardThermalDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSePCCardThermalDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSePCCardThermalDegraded
  • Additional combinations skipped.

Descriptions

cpqSePCCardThermalDegraded — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal Degraded (2). The manufacturer and product information strings as well as the slot number for the degraded PC Card is provided as parameters for this trap.

Source records

cpqSePCCardThermalDegraded

Status in source: unspecified.

Names: cpqSePCCardThermalDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSePCCardThermalDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSePCCardDeviceInfo",
    ",",
    "cpqSePCCardProductInfo",
    ",",
    "cpqSePCCardSlotIndex",
    "}",
    "DESCRIPTION",
    "\"This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal Degraded (2). The manufacturer and product information strings as well as the slot number for the degraded PC Card is provided as parameters for this trap.\"",
    "::=",
    "1002"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSePCCardDeviceInfo",
        "cpqSePCCardProductInfo",
        "cpqSePCCardSlotIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal Degraded (2). The manufacturer and product information strings as well as the slot number for the degraded PC Card is provided as parameters for this trap."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.814410+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.793162+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ1.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.793822+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo, 
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex } 
            DESCRIPTION 
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been 
                exceeded for safe operations thereby causing degraded operations. This trap 
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal 
                Degraded (2). 
                The manufacturer and product information strings as well as the slot number 
                for the degraded PC Card is provided as parameters for this trap." 
            --#TYPE "PC Card Thermal Degraded Status" 
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded." 
            --#ARGUMENTS {4} 
            --#SEVERITY MAJOR 
            --#TIMEINDEX 99 
            --#STATE DEGRADED 
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-StdEquipment.mib.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.810949+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqStdEquipment.mib.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.854099+00:00.

  • Preserved circitor archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB.mib
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.802860+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSTDEQ-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC card %d thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    		--#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY THERMAL        
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB

    Related source files and packages:


    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.148420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for safe operations thereby causing degraded operations. This trap
                will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
                Degraded (2).
                The manufacturer and product information strings as well as the slot number
                for the degraded PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Degraded Status (1002)"
            --#SUMMARY "Safe PC card %d thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY THERMAL
            ::= 1002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB

    Related source files and packages:


    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.262276+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00
1.3.6.1.4.1.232.0.22029 cpqRackServerBladeInserted00