Reference record for OID 1.3.6.1.4.1.232.0.1003

Parent
1.3.6.1.4.1.232.0 (0)
Node code
1003
Node name
cpqSePCCardThermalFailure
Numeric OID
1.3.6.1.4.1.232.0.1003
URN notation
urn:oid:1.3.6.1.4.1.232.0.1003
ASN.1 notation

{1 3 6 1 4 1 232 0 1003}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSePCCardThermalFailure(1003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSePCCardThermalFailure(1003)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/1003
  • /ISO/Identified-Organization/6/1/4/1/232/0/1003
  • /ISO/3/6/1/4/1/232/0/1003
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSePCCardThermalFailure
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSePCCardThermalFailure
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSePCCardThermalFailure
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSePCCardThermalFailure
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSePCCardThermalFailure
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSePCCardThermalFailure
  • Additional combinations skipped.

Descriptions

cpqSePCCardThermalFailure — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for degraded operations thereby causing failed operations. This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded (2) to Thermal Failure (3). The manufacturer and product information strings as well as the slot number for the failed PC Card is provided as parameters for this trap.

Source records

cpqSePCCardThermalFailure

Status in source: unspecified.

Names: cpqSePCCardThermalFailure

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSePCCardThermalFailure",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSePCCardDeviceInfo",
    ",",
    "cpqSePCCardProductInfo",
    ",",
    "cpqSePCCardSlotIndex",
    "}",
    "DESCRIPTION",
    "\"This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for degraded operations thereby causing failed operations. This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded (2) to Thermal Failure (3). The manufacturer and product information strings as well as the slot number for the failed PC Card is provided as parameters for this trap.\"",
    "::=",
    "1003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSePCCardDeviceInfo",
        "cpqSePCCardProductInfo",
        "cpqSePCCardSlotIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for degraded operations thereby causing failed operations. This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded (2) to Thermal Failure (3). The manufacturer and product information strings as well as the slot number for the failed PC Card is provided as parameters for this trap."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status"
            --#SUMMARY "Degraded PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Archived: 2026-10-19T00:22:07.814410+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status (1003)"
            --#SUMMARY "Degraded PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Archived: 2026-10-19T00:22:08.793162+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status"
            --#SUMMARY "Degraded PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ1.MIB.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Archived: 2026-10-19T00:22:08.793822+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo, 
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex } 
            DESCRIPTION 
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been 
                exceeded for degraded operations thereby causing failed operations. 
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded 
                (2) to Thermal Failure (3). 
                The manufacturer and product information strings as well as the slot number 
                for the failed PC Card is provided as parameters for this trap." 
            --#TYPE "PC Card Thermal Failure Status" 
            --#SUMMARY "Degraded PC Card %d Thermal operating conditions exceeded." 
            --#ARGUMENTS {4} 
            --#SEVERITY CRITICAL 
            --#TIMEINDEX 99 
            --#STATE NONOPERATIONAL 
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-StdEquipment.mib.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Archived: 2026-10-19T00:22:08.810949+00:00.

  • Preserved mibdepot archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status"
            --#SUMMARY "Degraded PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqStdEquipment.mib.txt
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Archived: 2026-10-19T00:22:08.854099+00:00.

  • Preserved circitor archive

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status (1003)"
            --#SUMMARY "Degraded PC Card %d Thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB.mib
    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Archived: 2026-10-19T00:22:16.802860+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSTDEQ-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status (1003)"
            --#SUMMARY "Degraded PC card %d thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    		--#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY THERMAL        
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB

    Related source files and packages:


    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.148420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTDEQ-MIB

    Published definition
    cpqSePCCardThermalFailure TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
                         cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
            DESCRIPTION
                "This trap is sent when the PC Card Slot Thermal Sensor threshold has been
                exceeded for degraded operations thereby causing failed operations.
                This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
                (2) to Thermal Failure (3).
                The manufacturer and product information strings as well as the slot number
                for the failed PC Card is provided as parameters for this trap."
            --#TYPE "PC Card Thermal Failure Status (1003)"
            --#SUMMARY "Degraded PC card %d thermal operating conditions exceeded."
            --#ARGUMENTS {4}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY THERMAL
            ::= 1003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTDEQ-MIB

    Related source files and packages:


    Source location: CPQSTDEQ-MIB::cpqSePCCardThermalFailure.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.262276+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136008079 mngmtAgentTrap_8079, mngmtAgentTrap-807900
1.3.6.1.4.1.232.0.136008080 mngmtAgentTrap_8080, mngmtAgentTrap-808000
1.3.6.1.4.1.232.0.136008081 mngmtAgentTrap_8081, mngmtAgentTrap-808100
1.3.6.1.4.1.232.0.136008082 mngmtAgentTrap_8082, mngmtAgentTrap-808200
1.3.6.1.4.1.232.0.136008083 mngmtAgentTrap_8083, mngmtAgentTrap-808300
1.3.6.1.4.1.232.0.136008084 mngmtAgentTrap_8084, mngmtAgentTrap-808400
1.3.6.1.4.1.232.0.136008085 mngmtAgentTrap_8085, mngmtAgentTrap-808500
1.3.6.1.4.1.232.0.136008086 mngmtAgentTrap_8086, mngmtAgentTrap-808600
1.3.6.1.4.1.232.0.136008087 mngmtAgentTrap_8087, mngmtAgentTrap-808700
1.3.6.1.4.1.232.0.136008088 mngmtAgentTrap_8088, mngmtAgentTrap-808800
1.3.6.1.4.1.232.0.136008089 mngmtAgentTrap_8089, mngmtAgentTrap-808900
1.3.6.1.4.1.232.0.136008090 mngmtAgentTrap_8090, mngmtAgentTrap-809000
1.3.6.1.4.1.232.0.136008091 mngmtAgentTrap-809100
1.3.6.1.4.1.232.0.136008092 mngmtAgentTrap-809200
1.3.6.1.4.1.232.0.136008093 mngmtAgentTrap-809300
1.3.6.1.4.1.232.0.136008094 mngmtAgentTrap-809400
1.3.6.1.4.1.232.0.136008095 mngmtAgentTrap-809500
1.3.6.1.4.1.232.0.136008096 mngmtAgentTrap-809600
1.3.6.1.4.1.232.0.136008097 mngmtAgentTrap-809700
1.3.6.1.4.1.232.0.136008098 mngmtAgentTrap-809800
1.3.6.1.4.1.232.0.136008099 mngmtAgentTrap-809900
1.3.6.1.4.1.232.0.136008100 mngmtAgentTrap-810000
1.3.6.1.4.1.232.0.136008104 mngmtAgentTrap-810400
1.3.6.1.4.1.232.0.136008106 mngmtAgentTrap-810600
1.3.6.1.4.1.232.0.136008107 mngmtAgentTrap-810700
1.3.6.1.4.1.232.0.136008108 mngmtAgentTrap-810800
1.3.6.1.4.1.232.0.136008109 mngmtAgentTrap-810900
1.3.6.1.4.1.232.0.136009001 mngmtAgentTrap_9001, mngmtAgentTrap-900100
1.3.6.1.4.1.232.0.136009002 mngmtAgentTrap_9002, mngmtAgentTrap-900200
1.3.6.1.4.1.232.0.136009003 mngmtAgentTrap_9003, mngmtAgentTrap-900300
1.3.6.1.4.1.232.0.136009004 mngmtAgentTrap_9004, mngmtAgentTrap-900400
1.3.6.1.4.1.232.0.136009005 mngmtAgentTrap_9005, mngmtAgentTrap-900500
1.3.6.1.4.1.232.0.136009006 mngmtAgentTrap_9006, mngmtAgentTrap-900600
1.3.6.1.4.1.232.0.136009007 mngmtAgentTrap_9007, mngmtAgentTrap-900700
1.3.6.1.4.1.232.0.136009008 mngmtAgentTrap_9008, mngmtAgentTrap-900800
1.3.6.1.4.1.232.0.136009009 mngmtAgentTrap_9009, mngmtAgentTrap-900900
1.3.6.1.4.1.232.0.136009010 mngmtAgentTrap_9010, mngmtAgentTrap-901000
1.3.6.1.4.1.232.0.136009011 mngmtAgentTrap_9011, mngmtAgentTrap-901100
1.3.6.1.4.1.232.0.136009012 mngmtAgentTrap_9012, mngmtAgentTrap-901200
1.3.6.1.4.1.232.0.136009013 mngmtAgentTrap_9013, mngmtAgentTrap-901300
1.3.6.1.4.1.232.0.136009014 mngmtAgentTrap_9014, mngmtAgentTrap-901400
1.3.6.1.4.1.232.0.136009015 mngmtAgentTrap_9015, mngmtAgentTrap-901500
1.3.6.1.4.1.232.0.136009016 mngmtAgentTrap_9016, mngmtAgentTrap-901600
1.3.6.1.4.1.232.0.136009017 mngmtAgentTrap_9017, mngmtAgentTrap-901700
1.3.6.1.4.1.232.0.136009018 mngmtAgentTrap_9018, mngmtAgentTrap-901800
1.3.6.1.4.1.232.0.136009019 mngmtAgentTrap_9019, mngmtAgentTrap-901900
1.3.6.1.4.1.232.0.136009020 mngmtAgentTrap_9020, mngmtAgentTrap-902000
1.3.6.1.4.1.232.0.136009021 mngmtAgentTrap_9021, mngmtAgentTrap-902100
1.3.6.1.4.1.232.0.136009022 mngmtAgentTrap_9022, mngmtAgentTrap-902200
1.3.6.1.4.1.232.0.136009023 mngmtAgentTrap_9023, mngmtAgentTrap-902300