OID reference

sCellEventTrap_3_1

1.3.6.1.4.1.232.0.13600769

Description

Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13600769
Node names
  • sCellEventTrap_3_1
  • sCellEventTrap-03-01
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.232.0.13600769
URN notation
urn:oid:1.3.6.1.4.1.232.0.13600769
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 232 0 13600769}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13600769
  • /ISO/Identified-Organization/6/1/4/1/232/0/13600769
  • /ISO/3/6/1/4/1/232/0/13600769
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-03-01
  • Additional combinations skipped.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

sCellEventTrap-03-01 · unspecified

sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  CRITICAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13600769

sCellEventTrap-03-01 · unspecified

sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
           --#TYPE      "StorageCell Event 0301400b"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  CRITICAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13600769

sCellEventTrap_3_1 · unspecified

sCellEventTrap_3_1 TRAP-TYPE  -- CAC Code: 40
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>"
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  CRITICAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13600769

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable.

Sources for this description

CircitorHPE networking MIB copies (LibreNMS/Observium Community)MIBdepot

See 1 matching source record

Description 2

Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)MIBdepot

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Circitor, HPE networking MIB copies (LibreNMS/Observium Community), and others1 record · 9 sources

Description 1

sCellEventTrap-03-01 · unspecifiedCircitor, HPE networking MIB copies (LibreNMS/Observium Community), and others9 sources

Status in source: unspecified.

Names: sCellEventTrap-03-01

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-03-01",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable.\"",
    "::=",
    "13600769"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
    ],
    null
  ]
}
Records for description 2HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot1 record · 2 sources

Description 2

sCellEventTrap_3_1 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community), MIBdepot2 sources

Status in source: unspecified.

Names: sCellEventTrap_3_1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_3_1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>\"",
    "::=",
    "13600769"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>"
    ],
    null
  ]
}

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.161001 switchFirmwareTransferred00
1.3.6.1.4.1.232.0.161002 switchConfigFileTransferred00
1.3.6.1.4.1.232.0.161003 switchTFTPTransferSucceeded00
1.3.6.1.4.1.232.0.161004 switchTFTPTransferFailed00
1.3.6.1.4.1.232.0.161005 switchFileInvalid00
1.3.6.1.4.1.232.0.161006 switchFanFailed00
1.3.6.1.4.1.232.0.161007 switchFanOk00
1.3.6.1.4.1.232.0.161008 switchTempSensorDegraded00
1.3.6.1.4.1.232.0.161009 switchTempSensorFailed00
1.3.6.1.4.1.232.0.161010 switchTempSensorOk00
1.3.6.1.4.1.232.0.161011 switchPostSuccess00
1.3.6.1.4.1.232.0.161012 switchLoginFailure00
1.3.6.1.4.1.232.0.161013 switchLocationChange00
1.3.6.1.4.1.232.0.161014 switchCubeTypeChange00
1.3.6.1.4.1.232.0.161015 switchSNTPServiceUnavailable00
1.3.6.1.4.1.232.0.169001 cpqiScsiLinkUp00
1.3.6.1.4.1.232.0.169002 cpqiScsiLinkDown00
1.3.6.1.4.1.232.0.172001 cpqIoDrvWearoutTrap00
1.3.6.1.4.1.232.0.172002 cpqIoDrvNonWritableTrap00
1.3.6.1.4.1.232.0.172003 cpqIoDrvFlashbackTrap00
1.3.6.1.4.1.232.0.172004 cpqIoDrvTempHighTrap00
1.3.6.1.4.1.232.0.172005 cpqIoDrvTempOkTrap00
1.3.6.1.4.1.232.0.172006 cpqIoDrvErrorTrap00
1.3.6.1.4.1.232.0.172007 cpqIoDrvPowerlossProtectTrap00
1.3.6.1.4.1.232.0.179001 cpqOneViewCriticalAlert00
1.3.6.1.4.1.232.0.179002 cpqOneViewWarningAlert00
1.3.6.1.4.1.232.0.179003 cpqOneViewOkAlert00
1.3.6.1.4.1.232.0.179004 cpqOneViewUnknownAlert00
1.3.6.1.4.1.232.0.13600256 sCellEventTrap_1_000
1.3.6.1.4.1.232.0.13600257 sCellEventTrap_1_100
1.3.6.1.4.1.232.0.13600258 sCellEventTrap-01-0200
1.3.6.1.4.1.232.0.13600512 sCellEventTrap-02-0000
1.3.6.1.4.1.232.0.13600768 sCellEventTrap_3_0, sCellEventTrap-03-0000
1.3.6.1.4.1.232.0.13600770 sCellEventTrap_3_2, sCellEventTrap-03-0200
1.3.6.1.4.1.232.0.13600771 sCellEventTrap_3_3, sCellEventTrap-03-0300
1.3.6.1.4.1.232.0.13600772 sCellEventTrap_3_4, sCellEventTrap-03-0400
1.3.6.1.4.1.232.0.13600773 sCellEventTrap_3_5, sCellEventTrap-03-0500
1.3.6.1.4.1.232.0.13600774 sCellEventTrap_3_6, sCellEventTrap-03-0600
1.3.6.1.4.1.232.0.13600775 sCellEventTrap_3_7, sCellEventTrap-03-0700
1.3.6.1.4.1.232.0.13600776 sCellEventTrap_3_8, sCellEventTrap-03-0800
1.3.6.1.4.1.232.0.13600777 sCellEventTrap-03-0900
1.3.6.1.4.1.232.0.13600778 sCellEventTrap-03-0a00
1.3.6.1.4.1.232.0.13600779 sCellEventTrap-03-0b00
1.3.6.1.4.1.232.0.13600780 sCellEventTrap-03-0c00
1.3.6.1.4.1.232.0.13600781 sCellEventTrap-03-0d00
1.3.6.1.4.1.232.0.13600782 sCellEventTrap-03-0e00
1.3.6.1.4.1.232.0.13600783 sCellEventTrap-03-0f00
1.3.6.1.4.1.232.0.13600784 sCellEventTrap-03-1000
1.3.6.1.4.1.232.0.13600785 sCellEventTrap-03-1100
1.3.6.1.4.1.232.0.13600786 sCellEventTrap-03-1200