Reference record for OID 1.3.6.1.4.1.232.0.13600769

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13600769
Node names
  • sCellEventTrap_3_1
  • sCellEventTrap-03-01
Numeric OID
1.3.6.1.4.1.232.0.13600769
URN notation
urn:oid:1.3.6.1.4.1.232.0.13600769
ASN.1 notation

{1 3 6 1 4 1 232 0 13600769}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-03-01(13600769)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-03-01(13600769)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13600769
  • /ISO/Identified-Organization/6/1/4/1/232/0/13600769
  • /ISO/3/6/1/4/1/232/0/13600769
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-03-01
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_3_1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-03-01
  • Additional combinations skipped.

Descriptions

sCellEventTrap-03-01 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable.

sCellEventTrap_3_1 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>

Source records

sCellEventTrap-03-01

Status in source: unspecified.

Names: sCellEventTrap-03-01

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-03-01",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable.\"",
    "::=",
    "13600769"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-03-01.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-03-01.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event 0301400b"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event 0301400b"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event 0301400b"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event 0301400b"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-03-01 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive has been rendered inoperable."
               --#TYPE      "StorageCell Event 0301400b"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-03-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap_3_1

Status in source: unspecified.

Names: sCellEventTrap_3_1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_3_1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>\"",
    "::=",
    "13600769"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>"
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_3_1 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>"
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_3_1.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_3_1 TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>"
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13600769
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB
    Source location: CPQHSV110V3-MIB::sCellEventTrap_3_1.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.3006 cpqDa2AccelBadDataTrap00
1.3.6.1.4.1.232.0.3007 cpqDa2AccelBatteryFailed00
1.3.6.1.4.1.232.0.3008 cpqDa3LogDrvStatusChange00
1.3.6.1.4.1.232.0.3009 cpqDa3SpareStatusChange00
1.3.6.1.4.1.232.0.3010 cpqDa3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3011 cpqDa3PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3012 cpqDa3AccelStatusChange00
1.3.6.1.4.1.232.0.3013 cpqDa3AccelBadDataTrap00
1.3.6.1.4.1.232.0.3014 cpqDa3AccelBatteryFailed00
1.3.6.1.4.1.232.0.3015 cpqDaCntlrStatusChange00
1.3.6.1.4.1.232.0.3016 cpqDaCntlrActive00
1.3.6.1.4.1.232.0.3017 cpqDa4SpareStatusChange00
1.3.6.1.4.1.232.0.3018 cpqDa4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3019 cpqDa4PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3020 cpqDaTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.3021 cpqDaTapeLibraryDoorStatusChange00
1.3.6.1.4.1.232.0.3022 cpqDaTapeDriveStatusChange00
1.3.6.1.4.1.232.0.3023 cpqDaTapeDriveCleaningRequired00
1.3.6.1.4.1.232.0.3024 cpqDaTapeDriveCleanTapeReplace00
1.3.6.1.4.1.232.0.3025 cpqDa5AccelStatusChange00
1.3.6.1.4.1.232.0.3026 cpqDa5AccelBadDataTrap00
1.3.6.1.4.1.232.0.3027 cpqDa5AccelBatteryFailed00
1.3.6.1.4.1.232.0.3028 cpqDa5CntlrStatusChange00
1.3.6.1.4.1.232.0.3029 cpqDa5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3030 cpqDa5PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3031 cpqDa2TapeLibraryStatusChange00
1.3.6.1.4.1.232.0.3032 cpqDa2TapeDriveStatusChange00
1.3.6.1.4.1.232.0.3033 cpqDa6CntlrStatusChange00
1.3.6.1.4.1.232.0.3034 cpqDa6LogDrvStatusChange00
1.3.6.1.4.1.232.0.3035 cpqDa6SpareStatusChange00
1.3.6.1.4.1.232.0.3036 cpqDa6PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3037 cpqDa6PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3038 cpqDa6AccelStatusChange00
1.3.6.1.4.1.232.0.3039 cpqDa6AccelBadDataTrap00
1.3.6.1.4.1.232.0.3040 cpqDa6AccelBatteryFailed00
1.3.6.1.4.1.232.0.3041 cpqDa6TapeLibraryStatusChange00
1.3.6.1.4.1.232.0.3042 cpqDa6TapeLibraryDoorStatusChange00
1.3.6.1.4.1.232.0.3043 cpqDa6TapeDriveStatusChange00
1.3.6.1.4.1.232.0.3044 cpqDa6TapeDriveCleaningRequired00
1.3.6.1.4.1.232.0.3045 cpqDa6TapeDriveCleanTapeReplace00
1.3.6.1.4.1.232.0.3046 cpqDa7PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3047 cpqDa7SpareStatusChange00
1.3.6.1.4.1.232.0.3048 cpqDaCntlrPartnerStatusChange00
1.3.6.1.4.1.232.0.3049 cpqDaPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.3903 cpqDaSmartArraySecureEraseFailed00
1.3.6.1.4.1.232.0.5001 cpqScsi2CntlrStatusChange00
1.3.6.1.4.1.232.0.5002 cpqScsi2LogDrvStatusChange00
1.3.6.1.4.1.232.0.5003 cpqScsi2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5004 cpqTapePhyDrvStatusChange00
1.3.6.1.4.1.232.0.5005 cpqScsi3CntlrStatusChange00