Description 1
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond.
Sources for this description
HPE networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.232.0.13601537
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond.
Identification
{1 3 6 1 4 1 232 0 13601537}
Available source records contain 6 distinct definitions; some records may not include a definition.
sCellEventTrap-06-01 TRAP-TYPE -- CAC Code: 4a
ENTERPRISE compaq
VARIABLES { scellNameDateTime,
scellSWComponent,
scellECode,
scellCAC,
scellEIP}
DESCRIPTION
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond."
--#TYPE "StorageCell Event 06014a08"
--#SUMMARY "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
--#ARGUMENTS {0,1,2,3,4,}
--#SEVERITY MINOR
--#TIMEINDEX 136
--#STATE WARNING
::= 13601537sCellEventTrap-06-01 TRAP-TYPE -- CAC Code: 4a
ENTERPRISE compaq
VARIABLES { scellNameDateTime,
scellSWComponent,
scellECode,
scellCAC,
scellEIP}
DESCRIPTION
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond."
--#TYPE "StorageCell Event"
--#SUMMARY "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
--#ARGUMENTS {0,1,2,3,4,}
--#SEVERITY MINOR
--#TIMEINDEX 136
--#STATE WARNING
::= 13601537sCellEventTrap_6_1 TRAP-TYPE -- CAC Code: 4a
ENTERPRISE compaq
VARIABLES { scellNameDateTime,
scellSWComponent,
scellECode,
scellCAC,
scellEIP}
DESCRIPTION
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>"
--#TYPE "StorageCell Event"
--#SUMMARY "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
--#ARGUMENTS {0,1,2,3,4,}
--#SEVERITY MINOR
--#TIMEINDEX 136
--#STATE WARNING
::= 13601537sCellEventTrap-06-01 TRAP-TYPE -- CAC Code: 4a
ENTERPRISE compaq
VARIABLES { scellNameDateTime,
scellSWComponent,
scellECode,
scellCAC,
scellEIP}
DESCRIPTION
"Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
--#TYPE "StorageCell Event"
--#SUMMARY "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
--#ARGUMENTS {0,1,2,3,4,}
--#SEVERITY MINOR
--#TIMEINDEX 136
--#STATE WARNING
::= 13601537sCellEventTrap-06-01 TRAP-TYPE -- CAC Code: 4a
ENTERPRISE compaq
VARIABLES { scellNameDateTime,
scellSWComponent,
scellECode,
scellCAC,
scellEIP}
DESCRIPTION
"Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
--#TYPE "StorageCell Event 06014a08"
--#SUMMARY "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
--#ARGUMENTS {0,1,2,3,4,}
--#SEVERITY MINOR
--#TIMEINDEX 136
--#STATE WARNING
::= 13601537sCellEventTrap-06-01 TRAP-TYPE -- CAC Code: 4a
ENTERPRISE compaq
VARIABLES { scellNameDateTime,
scellSWComponent,
scellECode,
scellCAC,
scellEIP}
DESCRIPTION
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond."
--#TYPE "StorageCell Event"
--#SUMMARY "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
--#ARGUMENTS {0,1,2,3,4,}
--#SEVERITY MINOR
--#TIMEINDEX 136
--#STATE WARNING
::= 13601537
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond.
HPE networking MIB copies (LibreNMS/Observium Community)
Description 2
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond.
CircitorHPE networking MIB copies (LibreNMS/Observium Community)
Description 3
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>
HPE networking MIB copies (LibreNMS/Observium Community)MIBdepot
Description 4
Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond.
HPE networking MIB copies (LibreNMS/Observium Community)
Description 5
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond.
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: unspecified.
Names: sCellEventTrap-06-01
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap-06-01",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond.\"",
"::=",
"13601537"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond."
],
null
]
}Vendor MIB copy from the Observium Community archive. HPE networking support.
Module: CPQHSV200V6-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Status in source: unspecified.
Names: sCellEventTrap-06-01
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap-06-01",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond.\"",
"::=",
"13601537"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond."
],
null
]
}Vendor MIB copy from the Observium Community archive. HPE networking support.
Module: CPQHSV-MIB
Same published definition (formatting differs; exact original is in the source file)
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Module: CPQHSV-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Status in source: unspecified.
Names: sCellEventTrap_6_1
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap_6_1",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>\"",
"::=",
"13601537"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>"
],
null
]
}Vendor MIB copy from the Observium Community archive. HPE networking support.
Module: CPQHSV110V3-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Status in source: unspecified.
Names: sCellEventTrap-06-01
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap-06-01",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond.\"",
"::=",
"13601537"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
],
null
]
}Vendor MIB copy from the Observium Community archive. HPE networking support.
Module: CPQHSV340V11-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Vendor MIB copy from the Observium Community archive. HPE networking support.
Module: CPQHSV300V11-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Status in source: unspecified.
Names: sCellEventTrap-06-01
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap-06-01",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond.\"",
"::=",
"13601537"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond."
],
null
]
}Module: CPQHSV300V9-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.232.0.13600867 | sCellEventTrap-03-63 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13600868 | sCellEventTrap-03-64 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13600869 | sCellEventTrap-03-65 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601024 | sCellEventTrap_4_0, sCellEventTrap-04-00 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601025 | sCellEventTrap_4_1, sCellEventTrap-04-01 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601026 | sCellEventTrap_4_2, sCellEventTrap-04-02 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601027 | sCellEventTrap_4_3, sCellEventTrap-04-03 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601028 | sCellEventTrap_4_4, sCellEventTrap-04-04 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601029 | sCellEventTrap_4_5, sCellEventTrap-04-05 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601030 | sCellEventTrap_4_6, sCellEventTrap-04-06 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601031 | sCellEventTrap_4_7, sCellEventTrap-04-07 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601032 | sCellEventTrap_4_8, sCellEventTrap-04-08 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601033 | sCellEventTrap_4_9, sCellEventTrap-04-09 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601034 | sCellEventTrap_4_a, sCellEventTrap-04-0a | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601035 | sCellEventTrap_4_b, sCellEventTrap-04-0b | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601036 | sCellEventTrap_4_c, sCellEventTrap-04-0c | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601037 | sCellEventTrap_4_d, sCellEventTrap-04-0d | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601038 | sCellEventTrap_4_e, sCellEventTrap-04-0e | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601039 | sCellEventTrap_4_f, sCellEventTrap-04-0f | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601040 | sCellEventTrap_4_10, sCellEventTrap-04-10 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601041 | sCellEventTrap_4_11, sCellEventTrap-04-11 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601042 | sCellEventTrap-04-12 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601043 | sCellEventTrap-04-13 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601044 | sCellEventTrap-04-14 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601045 | sCellEventTrap-04-15 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601046 | sCellEventTrap-04-16 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601048 | sCellEventTrap-04-18 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601049 | sCellEventTrap-04-19 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601050 | sCellEventTrap-04-1a | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601051 | sCellEventTrap-04-1b | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601054 | sCellEventTrap-04-1e | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601055 | sCellEventTrap-04-1f | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601536 | sCellEventTrap_6_0, sCellEventTrap-06-00 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601538 | sCellEventTrap_6_2, sCellEventTrap-06-02 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601539 | sCellEventTrap_6_3, sCellEventTrap-06-03 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601540 | sCellEventTrap_6_4, sCellEventTrap-06-04 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601541 | sCellEventTrap_6_5, sCellEventTrap-06-05 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601543 | sCellEventTrap_6_7, sCellEventTrap-06-07 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601544 | sCellEventTrap_6_8, sCellEventTrap-06-08 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601545 | sCellEventTrap_6_9, sCellEventTrap-06-09 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601546 | sCellEventTrap_6_a, sCellEventTrap-06-0a | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601547 | sCellEventTrap_6_b, sCellEventTrap-06-0b | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601548 | sCellEventTrap_6_c, sCellEventTrap-06-0c | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601549 | sCellEventTrap_6_d, sCellEventTrap-06-0d | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601550 | sCellEventTrap_6_e, sCellEventTrap-06-0e | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601551 | sCellEventTrap_6_f, sCellEventTrap-06-0f | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601552 | sCellEventTrap_6_10, sCellEventTrap-06-10 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601554 | sCellEventTrap_6_12, sCellEventTrap-06-12 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601555 | sCellEventTrap_6_13, sCellEventTrap-06-13 | 0 | 0 | |
| 1.3.6.1.4.1.232.0.13601556 | sCellEventTrap_6_14, sCellEventTrap-06-14 | 0 | 0 |