Reference record for OID 1.3.6.1.4.1.232.0.13601537

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601537
Node names
  • sCellEventTrap_6_1
  • sCellEventTrap-06-01
Numeric OID
1.3.6.1.4.1.232.0.13601537
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601537
ASN.1 notation

{1 3 6 1 4 1 232 0 13601537}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-01(13601537)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-01(13601537)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601537
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601537
  • /ISO/3/6/1/4/1/232/0/13601537
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-01
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-01
  • Additional combinations skipped.

Descriptions

sCellEventTrap-06-01 — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond.

sCellEventTrap-06-01 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond.

sCellEventTrap_6_1 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>

sCellEventTrap-06-01 — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond.

sCellEventTrap-06-01 — MIBdepot

Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond.

Source records

sCellEventTrap-06-01

Status in source: unspecified.

Names: sCellEventTrap-06-01

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-01",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond.\"",
    "::=",
    "13601537"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV200 controller has failed to respond."
               --#TYPE      "StorageCell Event 06014a08"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

sCellEventTrap-06-01

Status in source: unspecified.

Names: sCellEventTrap-06-01

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-01",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond.\"",
    "::=",
    "13601537"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-01.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV210 controller has failed to respond."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

sCellEventTrap_6_1

Status in source: unspecified.

Names: sCellEventTrap_6_1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>\"",
    "::=",
    "13601537"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>"
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_1 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>"
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_1.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_1 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>"
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_1.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-01

Status in source: unspecified.

Names: sCellEventTrap-06-01

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-01",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond.\"",
    "::=",
    "13601537"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
               --#TYPE      "StorageCell Event 06014a08"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
               --#TYPE      "StorageCell Event 06014a08"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
               --#TYPE      "StorageCell Event 06014a08"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Device port on the controller has failed to respond."
               --#TYPE      "StorageCell Event 06014a08"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-06-01.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap-06-01

Status in source: unspecified.

Names: sCellEventTrap-06-01

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-01",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond.\"",
    "::=",
    "13601537"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-06-01 TRAP-TYPE  -- CAC Code: 4a
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV300 controller has failed to respond."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601537
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-06-01.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18004 cpqNicRedundancyReduced00
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00