Reference record for OID 1.3.6.1.4.1.232.0.13601539

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601539
Node names
  • sCellEventTrap_6_3
  • sCellEventTrap-06-03
Numeric OID
1.3.6.1.4.1.232.0.13601539
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601539
ASN.1 notation

{1 3 6 1 4 1 232 0 13601539}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-03(13601539)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-03(13601539)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601539
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601539
  • /ISO/3/6/1/4/1/232/0/13601539
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-03
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_3
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-03
  • Additional combinations skipped.

Descriptions

sCellEventTrap-06-03 — MIBdepot

Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV300 controller via the mirror port or a Fibre Channel port has timed out.

sCellEventTrap-06-03 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV210 controller via the mirror port or a Fibre Channel port has timed out.

sCellEventTrap_6_3 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-06-03 — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV200 controller via the mirror port or a Fibre Channel port has timed out.

sCellEventTrap-06-03 — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out

Source records

sCellEventTrap-06-03

Status in source: unspecified.

Names: sCellEventTrap-06-03

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-03",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV300 controller via the mirror port or a Fibre Channel port has timed out.\"",
    "::=",
    "13601539"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV300 controller via the mirror port or a Fibre Channel port has timed out."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV300 controller via the mirror port or a Fibre Channel port has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-06-03.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

sCellEventTrap-06-03

Status in source: unspecified.

Names: sCellEventTrap-06-03

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-03",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV210 controller via the mirror port or a Fibre Channel port has timed out.\"",
    "::=",
    "13601539"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV210 controller via the mirror port or a Fibre Channel port has timed out."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV210 controller via the mirror port or a Fibre Channel port has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-03.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV210 controller via the mirror port or a Fibre Channel port has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

sCellEventTrap_6_3

Status in source: unspecified.

Names: sCellEventTrap_6_3

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_3",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13601539"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_3 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_3.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_3 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_3.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-03

Status in source: unspecified.

Names: sCellEventTrap-06-03

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-03",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV200 controller via the mirror port or a Fibre Channel port has timed out.\"",
    "::=",
    "13601539"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV200 controller via the mirror port or a Fibre Channel port has timed out."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV200 controller via the mirror port or a Fibre Channel port has timed out."
               --#TYPE      "StorageCell Event 06034713"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

sCellEventTrap-06-03

Status in source: unspecified.

Names: sCellEventTrap-06-03

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-03",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out\"",
    "::=",
    "13601539"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out"
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out"
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out"
               --#TYPE      "StorageCell Event 06034713"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out"
               --#TYPE      "StorageCell Event 06034713"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out"
               --#TYPE      "StorageCell Event 06034713"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-06-03 TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another controller via the mirror port or a Device port has timed out"
               --#TYPE      "StorageCell Event 06034713"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601539
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-06-03.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13603620 sCellEventTrap-0e-2400
1.3.6.1.4.1.232.0.13603621 sCellEventTrap-0e-2500
1.3.6.1.4.1.232.0.13603622 sCellEventTrap-0e-2600
1.3.6.1.4.1.232.0.13603623 sCellEventTrap-0e-2700
1.3.6.1.4.1.232.0.13603624 sCellEventTrap-0e-2800
1.3.6.1.4.1.232.0.13603625 sCellEventTrap-0e-2900
1.3.6.1.4.1.232.0.13603626 sCellEventTrap-0e-2a00
1.3.6.1.4.1.232.0.13603627 sCellEventTrap-0e-2b00
1.3.6.1.4.1.232.0.13603628 sCellEventTrap-0e-2c00
1.3.6.1.4.1.232.0.13603629 sCellEventTrap-0e-2d00
1.3.6.1.4.1.232.0.13603630 sCellEventTrap-0e-2e00
1.3.6.1.4.1.232.0.13603631 sCellEventTrap-0e-2f00
1.3.6.1.4.1.232.0.13603636 sCellEventTrap-0e-3400
1.3.6.1.4.1.232.0.13603637 sCellEventTrap-0e-3500
1.3.6.1.4.1.232.0.13603638 sCellEventTrap-0e-3600
1.3.6.1.4.1.232.0.13603639 sCellEventTrap-0e-3700
1.3.6.1.4.1.232.0.13603640 sCellEventTrap-0e-3800
1.3.6.1.4.1.232.0.13603641 sCellEventTrap-0e-3900
1.3.6.1.4.1.232.0.13603642 sCellEventTrap-0e-3a00
1.3.6.1.4.1.232.0.13603643 sCellEventTrap-0e-3b00
1.3.6.1.4.1.232.0.13603644 sCellEventTrap-0e-3c00
1.3.6.1.4.1.232.0.13603645 sCellEventTrap-0e-3d00
1.3.6.1.4.1.232.0.13603646 sCellEventTrap-0e-3e00
1.3.6.1.4.1.232.0.13603647 sCellEventTrap-0e-3f00
1.3.6.1.4.1.232.0.13603648 sCellEventTrap-0e-4000
1.3.6.1.4.1.232.0.13603649 sCellEventTrap-0e-4100
1.3.6.1.4.1.232.0.13603650 sCellEventTrap-0e-4200
1.3.6.1.4.1.232.0.13603651 sCellEventTrap-0e-4300
1.3.6.1.4.1.232.0.13603652 sCellEventTrap-0e-4400
1.3.6.1.4.1.232.0.13603653 sCellEventTrap-0e-4500
1.3.6.1.4.1.232.0.13603654 sCellEventTrap-0e-4600
1.3.6.1.4.1.232.0.13603655 sCellEventTrap-0e-4700
1.3.6.1.4.1.232.0.13603656 sCellEventTrap-0e-4800
1.3.6.1.4.1.232.0.13603657 sCellEventTrap-0e-4900
1.3.6.1.4.1.232.0.13603658 sCellEventTrap-0e-4a00
1.3.6.1.4.1.232.0.13603659 sCellEventTrap-0e-4b00
1.3.6.1.4.1.232.0.13603660 sCellEventTrap-0e-4c00
1.3.6.1.4.1.232.0.13603661 sCellEventTrap-0e-4d00
1.3.6.1.4.1.232.0.13603662 sCellEventTrap-0e-4e00
1.3.6.1.4.1.232.0.13603663 sCellEventTrap-0e-4f00
1.3.6.1.4.1.232.0.13603664 sCellEventTrap-0e-5000
1.3.6.1.4.1.232.0.13603665 sCellEventTrap-0e-5100
1.3.6.1.4.1.232.0.13603666 sCellEventTrap-0e-5200
1.3.6.1.4.1.232.0.13603667 sCellEventTrap-0e-5300
1.3.6.1.4.1.232.0.13603668 sCellEventTrap-0e-5400
1.3.6.1.4.1.232.0.13603669 sCellEventTrap-0e-5500
1.3.6.1.4.1.232.0.13603670 sCellEventTrap-0e-5600
1.3.6.1.4.1.232.0.13603671 sCellEventTrap-0e-5700
1.3.6.1.4.1.232.0.13603712 sCellEventTrap-0e-8000
1.3.6.1.4.1.232.0.13603713 sCellEventTrap-0e-8100