Reference record for OID 1.3.6.1.4.1.232.0.13601550

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601550
Node names
  • sCellEventTrap_6_e
  • sCellEventTrap-06-0e
Numeric OID
1.3.6.1.4.1.232.0.13601550
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601550
ASN.1 notation

{1 3 6 1 4 1 232 0 13601550}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-0e(13601550)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-0e(13601550)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601550
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601550
  • /ISO/3/6/1/4/1/232/0/13601550
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-0e
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_e
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-0e
  • Additional combinations skipped.

Descriptions

sCellEventTrap-06-0e — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed.

sCellEventTrap_6_e — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

Source records

sCellEventTrap-06-0e

Status in source: unspecified.

Names: sCellEventTrap-06-0e

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-0e",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed.\"",
    "::=",
    "13601550"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-0e TRAP-TYPE  -- CAC Code: 96
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601550
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-0e.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-0e TRAP-TYPE  -- CAC Code: 96
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed."
               --#TYPE      "StorageCell Event 060e9613"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601550
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-0e.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-0e TRAP-TYPE  -- CAC Code: 96
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601550
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-0e.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

sCellEventTrap_6_e

Status in source: unspecified.

Names: sCellEventTrap_6_e

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_e",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13601550"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_e TRAP-TYPE  -- CAC Code: 96
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601550
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_e.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_e TRAP-TYPE  -- CAC Code: 96
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601550
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_e.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13600786 sCellEventTrap-03-1200
1.3.6.1.4.1.232.0.13600787 sCellEventTrap-03-1300
1.3.6.1.4.1.232.0.13600788 sCellEventTrap-03-1400
1.3.6.1.4.1.232.0.13600789 sCellEventTrap-03-1500
1.3.6.1.4.1.232.0.13600790 sCellEventTrap-03-1600
1.3.6.1.4.1.232.0.13600791 sCellEventTrap-03-1700
1.3.6.1.4.1.232.0.13600792 sCellEventTrap-03-1800
1.3.6.1.4.1.232.0.13600793 sCellEventTrap-03-1900
1.3.6.1.4.1.232.0.13600794 sCellEventTrap-03-1a00
1.3.6.1.4.1.232.0.13600795 sCellEventTrap-03-1b00
1.3.6.1.4.1.232.0.13600796 sCellEventTrap-03-1c00
1.3.6.1.4.1.232.0.13600797 sCellEventTrap-03-1d00
1.3.6.1.4.1.232.0.13600798 sCellEventTrap-03-1e00
1.3.6.1.4.1.232.0.13600799 sCellEventTrap-03-1f00
1.3.6.1.4.1.232.0.13600800 sCellEventTrap-03-2000
1.3.6.1.4.1.232.0.13600801 sCellEventTrap-03-2100
1.3.6.1.4.1.232.0.13600802 sCellEventTrap-03-2200
1.3.6.1.4.1.232.0.13600803 sCellEventTrap-03-2300
1.3.6.1.4.1.232.0.13600804 sCellEventTrap-03-2400
1.3.6.1.4.1.232.0.13600805 sCellEventTrap-03-2500
1.3.6.1.4.1.232.0.13600806 sCellEventTrap-03-2600
1.3.6.1.4.1.232.0.13600807 sCellEventTrap-03-2700
1.3.6.1.4.1.232.0.13600808 sCellEventTrap-03-2800
1.3.6.1.4.1.232.0.13600809 sCellEventTrap-03-2900
1.3.6.1.4.1.232.0.13600810 sCellEventTrap-03-2a00
1.3.6.1.4.1.232.0.13600811 sCellEventTrap-03-2b00
1.3.6.1.4.1.232.0.13600812 sCellEventTrap-03-2c00
1.3.6.1.4.1.232.0.13600813 sCellEventTrap-03-2d00
1.3.6.1.4.1.232.0.13600814 sCellEventTrap-03-2e00
1.3.6.1.4.1.232.0.13600815 sCellEventTrap-03-2f00
1.3.6.1.4.1.232.0.13600816 sCellEventTrap-03-3000
1.3.6.1.4.1.232.0.13600817 sCellEventTrap-03-3100
1.3.6.1.4.1.232.0.13600818 sCellEventTrap-03-3200
1.3.6.1.4.1.232.0.13600819 sCellEventTrap-03-3300
1.3.6.1.4.1.232.0.13600820 sCellEventTrap-03-3400
1.3.6.1.4.1.232.0.13600821 sCellEventTrap-03-3500
1.3.6.1.4.1.232.0.13600832 sCellEventTrap-03-4000
1.3.6.1.4.1.232.0.13600833 sCellEventTrap-03-4100
1.3.6.1.4.1.232.0.13600834 sCellEventTrap-03-4200
1.3.6.1.4.1.232.0.13600835 sCellEventTrap-03-4300
1.3.6.1.4.1.232.0.13600836 sCellEventTrap-03-4400
1.3.6.1.4.1.232.0.13600837 sCellEventTrap-03-4500
1.3.6.1.4.1.232.0.13600838 sCellEventTrap-03-4600
1.3.6.1.4.1.232.0.13600839 sCellEventTrap-03-4700
1.3.6.1.4.1.232.0.13600840 sCellEventTrap-03-4800
1.3.6.1.4.1.232.0.13600841 sCellEventTrap-03-4900
1.3.6.1.4.1.232.0.13600842 sCellEventTrap-03-4a00
1.3.6.1.4.1.232.0.13600864 sCellEventTrap-03-6000
1.3.6.1.4.1.232.0.13600865 sCellEventTrap-03-6100
1.3.6.1.4.1.232.0.13600866 sCellEventTrap-03-6200