Reference record for OID 1.3.6.1.4.1.232.0.13601556

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601556
Node names
  • sCellEventTrap_6_14
  • sCellEventTrap-06-14
Numeric OID
1.3.6.1.4.1.232.0.13601556
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601556
ASN.1 notation

{1 3 6 1 4 1 232 0 13601556}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-14(13601556)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-14(13601556)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601556
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601556
  • /ISO/3/6/1/4/1/232/0/13601556
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-14
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_14
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-14
  • Additional combinations skipped.

Descriptions

sCellEventTrap_6_14 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-06-14 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port.

Source records

sCellEventTrap_6_14

Status in source: unspecified.

Names: sCellEventTrap_6_14

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_14",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13601556"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_14 TRAP-TYPE  -- CAC Code: 98
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601556
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_14.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_14 TRAP-TYPE  -- CAC Code: 98
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601556
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_14.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-14

Status in source: unspecified.

Names: sCellEventTrap-06-14

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-14",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port.\"",
    "::=",
    "13601556"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-14 TRAP-TYPE  -- CAC Code: 98
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601556
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-14.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-14 TRAP-TYPE  -- CAC Code: 98
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port."
               --#TYPE      "StorageCell Event 06149813"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601556
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-14.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-14 TRAP-TYPE  -- CAC Code: 98
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601556
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-06-14.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.6081 cpqHeNvdimmEraseError00
1.3.6.1.4.1.232.0.6082 cpqHeNvdimmArmingError00
1.3.6.1.4.1.232.0.6083 cpqHeNvdimmSanitizationOk00
1.3.6.1.4.1.232.0.6084 cpqHeNvdimmSanitizationError00
1.3.6.1.4.1.232.0.6085 cpqHeNvdimmControllerFirmwareError00
1.3.6.1.4.1.232.0.6086 cpqHeNvdimmErrorInterleaveOn00
1.3.6.1.4.1.232.0.6087 cpqHeNvdimmInterleaveOff00
1.3.6.1.4.1.232.0.6088 cpqHeNvdimmEventNotifyError00
1.3.6.1.4.1.232.0.6089 cpqHeNvdimmPersistencyLost00
1.3.6.1.4.1.232.0.6090 cpqHeNvdimmPersistencyRestored00
1.3.6.1.4.1.232.0.6091 cpqHeNvdimmLifecycleWarning00
1.3.6.1.4.1.232.0.6092 cpqHeNvdimmLogicalNvdimmError00
1.3.6.1.4.1.232.0.6093 cpqHeNvdimmConfigurationError00
1.3.6.1.4.1.232.0.6094 cpqHeNvdimmBatteryNotChargedwithWait00
1.3.6.1.4.1.232.0.6095 cpqHeNvdimmBatteryNotChargedwithNoWait00
1.3.6.1.4.1.232.0.6096 cpqHeDimmMemoryMapChanged00
1.3.6.1.4.1.232.0.6097 cpqHeNvdimmPersistantMemoryAddressError00
1.3.6.1.4.1.232.0.6098 cpqHeNvdimmInitializationError00
1.3.6.1.4.1.232.0.6099 cpqHePwrSupplyError00
1.3.6.1.4.1.232.0.6100 cpqHePwrSupplyErrorRepaired00
1.3.6.1.4.1.232.0.6101 cpqHeBbuError00
1.3.6.1.4.1.232.0.6102 cpqHeBbuErrorRepaired00
1.3.6.1.4.1.232.0.6103 cpqHeNoPowerSupplyDetected00
1.3.6.1.4.1.232.0.6104 cpqHePowerProtectionFault00
1.3.6.1.4.1.232.0.6105 cpqHePowerFuseDegraded00
1.3.6.1.4.1.232.0.6106 cpqHeTPMSecureEraseFailed00
1.3.6.1.4.1.232.0.6107 cpqHeSPISecureEraseFailed00
1.3.6.1.4.1.232.0.6108 cpqHePMMSecureEraseFailed00
1.3.6.1.4.1.232.0.6109 cpqHeNANDSecureEraseFailed00
1.3.6.1.4.1.232.0.6110 cpqHeSedPassphrasefail00
1.3.6.1.4.1.232.0.6111 cpqHeSedUnlockfail00
1.3.6.1.4.1.232.0.6112 cpqHePMMHealthFailure00
1.3.6.1.4.1.232.0.6113 cpqHePMMLessUsageRemainingAlert00
1.3.6.1.4.1.232.0.6114 cpqHePMMConfigErr00
1.3.6.1.4.1.232.0.6115 cpqHePMMShutdownWarning00
1.3.6.1.4.1.232.0.6116 cpqHePMMCorrErrThreshold00
1.3.6.1.4.1.232.0.6117 cpqHePMMBootStatusRegWarning00
1.3.6.1.4.1.232.0.6118 cpqHeInletAmbientPreCautionThresAlert00
1.3.6.1.4.1.232.0.6119 cpqHeCoolingModuleDegraded00
1.3.6.1.4.1.232.0.6120 cpqHeCoolingModuleFailed00
1.3.6.1.4.1.232.0.6121 cpqHeCoolingModuleRedundancyLost00
1.3.6.1.4.1.232.0.6122 cpqHeCoolingModuleRedundancyRestored00
1.3.6.1.4.1.232.0.8001 cpqSs2FanStatusChange00
1.3.6.1.4.1.232.0.8002 cpqSsTempFailed00
1.3.6.1.4.1.232.0.8003 cpqSsTempDegraded00
1.3.6.1.4.1.232.0.8004 cpqSsTempOk00
1.3.6.1.4.1.232.0.8005 cpqSsSidePanelInPlace00
1.3.6.1.4.1.232.0.8006 cpqSsSidePanelRemoved00
1.3.6.1.4.1.232.0.8007 cpqSsPwrSupplyDegraded00
1.3.6.1.4.1.232.0.8008 cpqSs3FanStatusChange00