Reference record for OID 1.3.6.1.4.1.232.0.13601557

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601557
Node names
  • sCellEventTrap_6_15
  • sCellEventTrap-06-15
Numeric OID
1.3.6.1.4.1.232.0.13601557
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601557
ASN.1 notation

{1 3 6 1 4 1 232 0 13601557}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-15(13601557)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-15(13601557)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601557
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601557
  • /ISO/3/6/1/4/1/232/0/13601557
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-15
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_15
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-15
  • Additional combinations skipped.

Descriptions

sCellEventTrap_6_15 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-06-15 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port.

Source records

sCellEventTrap_6_15

Status in source: unspecified.

Names: sCellEventTrap_6_15

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_15",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13601557"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_15 TRAP-TYPE  -- CAC Code: 99
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601557
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_15.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_15 TRAP-TYPE  -- CAC Code: 99
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601557
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_15.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-15

Status in source: unspecified.

Names: sCellEventTrap-06-15

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-15",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port.\"",
    "::=",
    "13601557"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-15 TRAP-TYPE  -- CAC Code: 99
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601557
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-15.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-15 TRAP-TYPE  -- CAC Code: 99
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port."
               --#TYPE      "StorageCell Event 06159913"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601557
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-15.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-15 TRAP-TYPE  -- CAC Code: 99
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601557
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-15.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18004 cpqNicRedundancyReduced00
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00