Reference record for OID 1.3.6.1.4.1.232.0.13601564

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601564
Node names
  • sCellEventTrap_6_1c
  • sCellEventTrap-06-1c
Numeric OID
1.3.6.1.4.1.232.0.13601564
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601564
ASN.1 notation

{1 3 6 1 4 1 232 0 13601564}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-1c(13601564)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-1c(13601564)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601564
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601564
  • /ISO/3/6/1/4/1/232/0/13601564
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-1c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_1c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-1c
  • Additional combinations skipped.

Descriptions

sCellEventTrap_6_1c — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-06-1c — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out.

Source records

sCellEventTrap_6_1c

Status in source: unspecified.

Names: sCellEventTrap_6_1c

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_1c",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13601564"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_1c.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-1c

Status in source: unspecified.

Names: sCellEventTrap-06-1c

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-1c",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out.\"",
    "::=",
    "13601564"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-1c.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-06-1c.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event 061c4709"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB

    Related source files and packages:


    Source location: CPQHSV340V11-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event 061c4709"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB

    Related source files and packages:


    Source location: CPQHSV300V11-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event 061c4709"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB

    Related source files and packages:


    Source location: CPQHSV360V11-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event 061c4709"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB

    Related source files and packages:


    Source location: CPQHSV450V11-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-06-1c TRAP-TYPE  -- CAC Code: 47
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out."
               --#TYPE      "StorageCell Event 061c4709"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601564
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB

    Related source files and packages:


    Source location: CPQHSV400V11-MIB::sCellEventTrap-06-1c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22029 cpqRackServerBladeInserted00
1.3.6.1.4.1.232.0.22030 cpqRackPowerChassisNotLoadBalanced00
1.3.6.1.4.1.232.0.22031 cpqRackPowerChassisDcPowerProblem00
1.3.6.1.4.1.232.0.22032 cpqRackPowerChassisAcFacilityPowerExceeded00
1.3.6.1.4.1.232.0.22033 cpqRackPowerUnknownPowerConsumption00
1.3.6.1.4.1.232.0.22034 cpqRackPowerChassisLoadBalancingWireMissing00
1.3.6.1.4.1.232.0.22035 cpqRackPowerChassisTooManyPowerChassis00
1.3.6.1.4.1.232.0.22036 cpqRackPowerChassisConfigError00
1.3.6.1.4.1.232.0.22037 cpqRackEnclosureManagerDegraded00
1.3.6.1.4.1.232.0.22038 cpqRackEnclosureManagerOk00
1.3.6.1.4.1.232.0.22039 cpqRackEnclosureManagerRemoved00
1.3.6.1.4.1.232.0.22040 cpqRackEnclosureManagerInserted00
1.3.6.1.4.1.232.0.22041 cpqRackManagerPrimaryRole00
1.3.6.1.4.1.232.0.22042 cpqRackServerBladeEKeyingFailed00
1.3.6.1.4.1.232.0.22043 cpqRackServerBladeEKeyingOK00
1.3.6.1.4.1.232.0.22044 cpqRackNetConnectorRemoved00
1.3.6.1.4.1.232.0.22045 cpqRackNetConnectorInserted00
1.3.6.1.4.1.232.0.22046 cpqRackNetConnectorFailed00
1.3.6.1.4.1.232.0.22047 cpqRackNetConnectorDegraded00
1.3.6.1.4.1.232.0.22048 cpqRackNetConnectorOk00
1.3.6.1.4.1.232.0.22049 cpqRackServerBladeToLowPower00
1.3.6.1.4.1.232.0.22050 cpqRackServerBladeRemoved200
1.3.6.1.4.1.232.0.22051 cpqRackServerBladeInserted200
1.3.6.1.4.1.232.0.22052 cpqRackServerBladeStatusRepaired00
1.3.6.1.4.1.232.0.22053 cpqRackServerBladeStatusDegraded00
1.3.6.1.4.1.232.0.22054 cpqRackServerBladeStatusCritical00
1.3.6.1.4.1.232.0.22055 cpqRackServerBladeGrpCapTimeout00
1.3.6.1.4.1.232.0.22056 cpqRackServerBladeUnexpectedShutdown00
1.3.6.1.4.1.232.0.22057 cpqRackServerBladeMangementControllerFirmwareUpdating00
1.3.6.1.4.1.232.0.22058 cpqRackServerBladeMangementControllerFirmwareUpdateComplete00
1.3.6.1.4.1.232.0.22059 cpqRackServerBladeSystemBIOSFirmwareUpdating00
1.3.6.1.4.1.232.0.22060 cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted00
1.3.6.1.4.1.232.0.22061 cpqRackServerBladeFrontIOBlankingActive00
1.3.6.1.4.1.232.0.22062 cpqRackServerBladeRemoteFrontIOBlankingInactive00
1.3.6.1.4.1.232.0.22063 cpqRackServerBladeDiagnosticAdaptorInserted00
1.3.6.1.4.1.232.0.22064 cpqRackServerBladeDiagnosticAdaptorRemoved00
1.3.6.1.4.1.232.0.22065 cpqRackServerBladeEnteredPXEBootMode00
1.3.6.1.4.1.232.0.22066 cpqRackServerBladeExitedPXEBootMode00
1.3.6.1.4.1.232.0.22067 cpqRackServerBladeWarmReset00
1.3.6.1.4.1.232.0.22068 cpqRackServerBladePOSTCompleted00
1.3.6.1.4.1.232.0.22069 cpqRackServerBladePoweredOn00
1.3.6.1.4.1.232.0.22070 cpqRackServerBladePoweredOff00
1.3.6.1.4.1.232.0.22071 cpqRackInformationalEAETrap00
1.3.6.1.4.1.232.0.22072 cpqRackMinorEAETrap00
1.3.6.1.4.1.232.0.22073 cpqRackMajorEAETrap00
1.3.6.1.4.1.232.0.22074 cpqRackCriticalEAETrap00
1.3.6.1.4.1.232.0.22075 cpqRackPowerMinorEAETrap00
1.3.6.1.4.1.232.0.22076 cpqRackPowerMajorEAETrap00
1.3.6.1.4.1.232.0.22077 cpqRackPowerCriticalEAETrap00
1.3.6.1.4.1.232.0.22078 cpqRackServerBladePartitionChange00