Status in source: unspecified.
Technical details
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap_6_2b",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.\"",
"::=",
"13601579"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
],
null
]
}