Reference record for OID 1.3.6.1.4.1.232.0.13601579

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601579
Node names
  • sCellEventTrap_6_2b
  • sCellEventTrap-06-2b
Numeric OID
1.3.6.1.4.1.232.0.13601579
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601579
ASN.1 notation

{1 3 6 1 4 1 232 0 13601579}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601579
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601579
  • /ISO/3/6/1/4/1/232/0/13601579
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-2b
  • Additional combinations skipped.

Descriptions

sCellEventTrap_6_2b — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.

sCellEventTrap-06-2b — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable.

Source records

sCellEventTrap_6_2b

Status in source: unspecified.

Names: sCellEventTrap_6_2b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_2b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.\"",
    "::=",
    "13601579"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_2b.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-2b

Status in source: unspecified.

Names: sCellEventTrap-06-2b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-2b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable.\"",
    "::=",
    "13601579"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-2b.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event 062b4004"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22079 cpqRackInformationalWSMANTrap00
1.3.6.1.4.1.232.0.22080 cpqRackMinorWSMANTrap00
1.3.6.1.4.1.232.0.22081 cpqRackMajorWSMANTrap00
1.3.6.1.4.1.232.0.22082 cpqRackCriticalWSMANTrap00
1.3.6.1.4.1.232.0.22083 cpqRackEnclosureManagerLinkDown00
1.3.6.1.4.1.232.0.22084 cpqRackEnclosureManagerLinkUp00
1.3.6.1.4.1.232.0.22085 cpqRackErsCommFailure00
1.3.6.1.4.1.232.0.22086 cpqRackPowerSubsystemOverloadConditionRepaired00
1.3.6.1.4.1.232.0.22087 cpqRackPowerSubsystemRedundancyOk00
1.3.6.1.4.1.232.0.22088 cpqRackNetConnectorTempDegraded00
1.3.6.1.4.1.232.0.22089 cpqRackNetConnectorTempOk00
1.3.6.1.4.1.232.0.22090 cpqRackEnvironmentalLeakDetected00
1.3.6.1.4.1.232.0.22091 cpqRackEnvironmentalDoorState00
1.3.6.1.4.1.232.0.22092 cpqRackEnvironmentalAirTempSensor00
1.3.6.1.4.1.232.0.22093 cpqRackEnvironmentalControlValveStatus00
1.3.6.1.4.1.232.0.22094 cpqRackEnvironmentalWaterTempThresholdExceeded00
1.3.6.1.4.1.232.0.22095 cpqRackEnvironmentalFlowSensorStatus00
1.3.6.1.4.1.232.0.22096 cpqRackEnvironmentalWaterPressureThresholdExceeded00
1.3.6.1.4.1.232.0.22097 cpqRackEnvironmentalAutomaticRapidPowerOff00
1.3.6.1.4.1.232.0.22098 cpqRackEnvironmentalRopeLeakDetectorEvent00
1.3.6.1.4.1.232.0.22099 cpqRackEnvironmentalTemperatureThresholdExceeded00
1.3.6.1.4.1.232.0.22100 cpqRackEnvironmentalHumidityThresholdExceeded00
1.3.6.1.4.1.232.0.22101 cpqRackEnvironmentalControllerOnBoardBattery00
1.3.6.1.4.1.232.0.22102 cpqRackEnvironmentalControllerAPMCommunicationFailure00
1.3.6.1.4.1.232.0.22103 cpqRackEnvironmentalLeakDetectedCritical00
1.3.6.1.4.1.232.0.22104 cpqRackPowerSubsystemReductionModeActivate00
1.3.6.1.4.1.232.0.22105 cpqRackPowerSubsystemReductionModeDeactivate00
1.3.6.1.4.1.232.0.23001 cpqNodeTemperatureDegraded00
1.3.6.1.4.1.232.0.23002 cpqNodeTemperatureOk00
1.3.6.1.4.1.232.0.23003 cpqNodeTemperatureFailed00
1.3.6.1.4.1.232.0.23004 cpqNodeErrorEvent00
1.3.6.1.4.1.232.0.23010 cpqNodePowerOn00
1.3.6.1.4.1.232.0.23011 cpqNodePowerOff00
1.3.6.1.4.1.232.0.99999 cpqGenericUnregistered00
1.3.6.1.4.1.232.0.136001 emuEventTrapInformative00
1.3.6.1.4.1.232.0.136002 emuEventTrapNoncritical00
1.3.6.1.4.1.232.0.136003 emuEventTrapCritical00
1.3.6.1.4.1.232.0.136004 emuEventTrapUnrecoverable00
1.3.6.1.4.1.232.0.140001 cpqICAAdd00
1.3.6.1.4.1.232.0.140002 cpqICADelete00
1.3.6.1.4.1.232.0.140003 cpqICAPropertyChange00
1.3.6.1.4.1.232.0.140004 cpqICAMove00
1.3.6.1.4.1.232.0.140005 cpqICAImportRestoreStart00
1.3.6.1.4.1.232.0.140006 cpqICAImportRestoreEnd00
1.3.6.1.4.1.232.0.150001 cpqDMIIndicationInfo00
1.3.6.1.4.1.232.0.150002 cpqDMIIndicationMonitor00
1.3.6.1.4.1.232.0.150003 cpqDMIIndicationOK00
1.3.6.1.4.1.232.0.150004 cpqDMIIndicationNonCritical00
1.3.6.1.4.1.232.0.150005 cpqDMIIndicationCritical00
1.3.6.1.4.1.232.0.150006 cpqDMIIndicationNonNonRecoverable00