Reference record for OID 1.3.6.1.4.1.232.0.13602412

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13602412
Node names
  • sCellEventTrap_9_6c
  • sCellEventTrap-09-6c
Numeric OID
1.3.6.1.4.1.232.0.13602412
URN notation
urn:oid:1.3.6.1.4.1.232.0.13602412
ASN.1 notation

{1 3 6 1 4 1 232 0 13602412}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13602412
  • /ISO/Identified-Organization/6/1/4/1/232/0/13602412
  • /ISO/3/6/1/4/1/232/0/13602412
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-09-6c
  • Additional combinations skipped.

Descriptions

sCellEventTrap_9_6c — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set.

sCellEventTrap-09-6c — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Normal -- informational in nature. The usage state of a Volume changed.

Source records

sCellEventTrap_9_6c

Status in source: unspecified.

Names: sCellEventTrap_9_6c

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_9_6c",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set.\"",
    "::=",
    "13602412"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_9_6c TRAP-TYPE  -- CAC Code: 0
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_9_6c.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_9_6c TRAP-TYPE  -- CAC Code: 0
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_9_6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-09-6c

Status in source: unspecified.

Names: sCellEventTrap-09-6c

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-6c",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Normal -- informational in nature. The usage state of a Volume changed.\"",
    "::=",
    "13602412"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Normal -- informational in nature. The usage state of a Volume changed."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-09-6c.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-09-6c.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.6031 cpqHe3FltTolPowerSupplyFailed00
1.3.6.1.4.1.232.0.6032 cpqHe3FltTolPowerRedundancyLost00
1.3.6.1.4.1.232.0.6033 cpqHe3FltTolPowerSupplyInserted00
1.3.6.1.4.1.232.0.6034 cpqHe3FltTolPowerSupplyRemoved00
1.3.6.1.4.1.232.0.6035 cpqHe3FltTolFanDegraded00
1.3.6.1.4.1.232.0.6036 cpqHe3FltTolFanFailed00
1.3.6.1.4.1.232.0.6037 cpqHe3FltTolFanRedundancyLost00
1.3.6.1.4.1.232.0.6038 cpqHe3FltTolFanInserted00
1.3.6.1.4.1.232.0.6039 cpqHe3FltTolFanRemoved00
1.3.6.1.4.1.232.0.6040 cpqHe3TemperatureFailed00
1.3.6.1.4.1.232.0.6041 cpqHe3TemperatureDegraded00
1.3.6.1.4.1.232.0.6042 cpqHe3TemperatureOk00
1.3.6.1.4.1.232.0.6043 cpqHe3PowerConverterDegraded00
1.3.6.1.4.1.232.0.6044 cpqHe3PowerConverterFailed00
1.3.6.1.4.1.232.0.6045 cpqHe3PowerConverterRedundancyLost00
1.3.6.1.4.1.232.0.6046 cpqHe3CacheAccelParityError00
1.3.6.1.4.1.232.0.6047 cpqHeResilientMemOnlineSpareEngaged00
1.3.6.1.4.1.232.0.6048 cpqHe4FltTolPowerSupplyOk00
1.3.6.1.4.1.232.0.6049 cpqHe4FltTolPowerSupplyDegraded00
1.3.6.1.4.1.232.0.6050 cpqHe4FltTolPowerSupplyFailed00
1.3.6.1.4.1.232.0.6051 cpqHeResilientMemMirroredMemoryEngaged00
1.3.6.1.4.1.232.0.6052 cpqHeResilientAdvancedECCMemoryEngaged00
1.3.6.1.4.1.232.0.6053 cpqHeResilientMemXorMemoryEngaged00
1.3.6.1.4.1.232.0.6054 cpqHe3FltTolPowerRedundancyRestored00
1.3.6.1.4.1.232.0.6055 cpqHe3FltTolFanRedundancyRestored00
1.3.6.1.4.1.232.0.6056 cpqHe4CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6057 cpqHeResMemBoardRemoved00
1.3.6.1.4.1.232.0.6058 cpqHeResMemBoardInserted00
1.3.6.1.4.1.232.0.6059 cpqHeResMemBoardBusError00
1.3.6.1.4.1.232.0.6060 cpqHeEventOccurred00
1.3.6.1.4.1.232.0.6061 cpqHeManagementProcInReset00
1.3.6.1.4.1.232.0.6062 cpqHeManagementProcReady00
1.3.6.1.4.1.232.0.6063 cpqHeManagementProcFailedReset00
1.3.6.1.4.1.232.0.6064 cpqHe5CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6065 cpqHe5ResMemBoardRemoved00
1.3.6.1.4.1.232.0.6066 cpqHe5ResMemBoardInserted00
1.3.6.1.4.1.232.0.6067 cpqHe5ResMemBoardBusError00
1.3.6.1.4.1.232.0.6068 cpqHeResilientMemLockStepMemoryEngaged00
1.3.6.1.4.1.232.0.6069 cpqHe4FltTolPowerSupplyACpowerloss00
1.3.6.1.4.1.232.0.6070 cpqHeSysBatteryFailed00
1.3.6.1.4.1.232.0.6071 cpqHeSysBatteryRemoved00
1.3.6.1.4.1.232.0.6072 cpqHeSysPwrAllocationNotOptimized00
1.3.6.1.4.1.232.0.6073 cpqHeSysPwrOnDenied00
1.3.6.1.4.1.232.0.6074 cpqHePowerFailureError00
1.3.6.1.4.1.232.0.6075 cpqHeInterlockFailureError00
1.3.6.1.4.1.232.0.6076 cpqHeNvdimmBackupError00
1.3.6.1.4.1.232.0.6077 cpqHeNvdimmRestoreError00
1.3.6.1.4.1.232.0.6078 cpqHeNvdimmUncorrectableMemoryError00
1.3.6.1.4.1.232.0.6079 cpqHeNvdimmBackupPowerError00
1.3.6.1.4.1.232.0.6080 cpqHeNvdimmNVDIMMControllerError00