Reference record for OID 1.3.6.1.4.1.232.0.13602412

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13602412
Node names
  • sCellEventTrap_9_6c
  • sCellEventTrap-09-6c
Numeric OID
1.3.6.1.4.1.232.0.13602412
URN notation
urn:oid:1.3.6.1.4.1.232.0.13602412
ASN.1 notation

{1 3 6 1 4 1 232 0 13602412}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-6c(13602412)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-6c(13602412)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13602412
  • /ISO/Identified-Organization/6/1/4/1/232/0/13602412
  • /ISO/3/6/1/4/1/232/0/13602412
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-09-6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_9_6c
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-09-6c
  • Additional combinations skipped.

Descriptions

sCellEventTrap_9_6c — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set.

sCellEventTrap-09-6c — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Normal -- informational in nature. The usage state of a Volume changed.

Source records

sCellEventTrap_9_6c

Status in source: unspecified.

Names: sCellEventTrap_9_6c

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_9_6c",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set.\"",
    "::=",
    "13602412"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_9_6c TRAP-TYPE  -- CAC Code: 0
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_9_6c.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_9_6c TRAP-TYPE  -- CAC Code: 0
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_9_6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-09-6c

Status in source: unspecified.

Names: sCellEventTrap-09-6c

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-6c",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Normal -- informational in nature. The usage state of a Volume changed.\"",
    "::=",
    "13602412"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Normal -- informational in nature. The usage state of a Volume changed."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-09-6c.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-09-6c.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-09-6c TRAP-TYPE  -- CAC Code: 00
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Normal -- informational in nature. The usage state of a Volume changed."
               --#TYPE      "StorageCell Event 096c000f"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  INFORMATIONAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602412
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-09-6c.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.9026 cpqSm2FwUpdateUploadFailed00
1.3.6.1.4.1.232.0.9027 cpqSm2SecurityStateChange00
1.3.6.1.4.1.232.0.9028 cpqSm2WDTimerReset00
1.3.6.1.4.1.232.0.9029 cpqSm2OverallSecStateAtRisk00
1.3.6.1.4.1.232.0.9030 cpqSm2OverallSecStatusChange00
1.3.6.1.4.1.232.0.10001 cpqMeRisingAlarm00
1.3.6.1.4.1.232.0.10002 cpqMeFallingAlarm00
1.3.6.1.4.1.232.0.10003 cpqMe2RisingAlarm00
1.3.6.1.4.1.232.0.10004 cpqMe2FallingAlarm00
1.3.6.1.4.1.232.0.10005 cpqMeRisingAlarmExtended00
1.3.6.1.4.1.232.0.10006 cpqMeFallingAlarmExtended00
1.3.6.1.4.1.232.0.10007 cpqMeCriticalRisingAlarmExtended00
1.3.6.1.4.1.232.0.10008 cpqMeCriticalFallingAlarmExtended00
1.3.6.1.4.1.232.0.11001 cpqHoGenericTrap00
1.3.6.1.4.1.232.0.11002 cpqHoAppErrorTrap00
1.3.6.1.4.1.232.0.11003 cpqHo2GenericTrap00
1.3.6.1.4.1.232.0.11004 cpqHo2AppErrorTrap00
1.3.6.1.4.1.232.0.11005 cpqHo2NicStatusOk00
1.3.6.1.4.1.232.0.11006 cpqHo2NicStatusFailed00
1.3.6.1.4.1.232.0.11007 cpqHo2NicSwitchoverOccurred00
1.3.6.1.4.1.232.0.11008 cpqHo2NicStatusOk200
1.3.6.1.4.1.232.0.11009 cpqHo2NicStatusFailed200
1.3.6.1.4.1.232.0.11010 cpqHo2NicSwitchoverOccurred200
1.3.6.1.4.1.232.0.11011 cpqHoProcessEventTrap00
1.3.6.1.4.1.232.0.11012 cpqHoProcessCountWarning00
1.3.6.1.4.1.232.0.11013 cpqHoProcessCountNormal00
1.3.6.1.4.1.232.0.11014 cpqHoCriticalSoftwareUpdateTrap00
1.3.6.1.4.1.232.0.11015 cpqHoCrashDumpNotEnabledTrap00
1.3.6.1.4.1.232.0.11016 cpqHoBootPagingFileTooSmallTrap00
1.3.6.1.4.1.232.0.11017 cpqHoSWRunningStatusChangeTrap00
1.3.6.1.4.1.232.0.11018 cpqHo2PowerThresholdTrap00
1.3.6.1.4.1.232.0.11019 cpqHoBootPagingFileOrFreeSpaceTooSmallTrap00
1.3.6.1.4.1.232.0.11020 cpqHoMibHealthStatusArrayChangeTrap00
1.3.6.1.4.1.232.0.12001 cpqUpsLineFailed00
1.3.6.1.4.1.232.0.12002 cpqUpsLineOk00
1.3.6.1.4.1.232.0.12003 cpqUpsShutdown00
1.3.6.1.4.1.232.0.12004 cpqUpsConfirmation00
1.3.6.1.4.1.232.0.12005 cpqUpsBatteryLow00
1.3.6.1.4.1.232.0.12006 cpqUps2LineFailed00
1.3.6.1.4.1.232.0.12007 cpqUps2LineOk00
1.3.6.1.4.1.232.0.12008 cpqUps2Shutdown00
1.3.6.1.4.1.232.0.12009 cpqUps2Confirmation00
1.3.6.1.4.1.232.0.12010 cpqUps2BatteryLow00
1.3.6.1.4.1.232.0.12011 cpqUpsOverload00
1.3.6.1.4.1.232.0.12012 cpqUpsPendingBatteryFailure00
1.3.6.1.4.1.232.0.12013 cpqUpsGenericCritical00
1.3.6.1.4.1.232.0.12014 cpqUpsGenericInfo00
1.3.6.1.4.1.232.0.13001 cpqRsPartnerFailed00
1.3.6.1.4.1.232.0.13002 cpqRsStandbyCableFailure00
1.3.6.1.4.1.232.0.13003 cpqRsStandbyFailure00