Reference record for OID 1.3.6.1.4.1.232.0.13602511

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13602511
Node names
  • sCellEventTrap_9_cf
  • sCellEventTrap-09-cf
Numeric OID
1.3.6.1.4.1.232.0.13602511
URN notation
urn:oid:1.3.6.1.4.1.232.0.13602511
ASN.1 notation

{1 3 6 1 4 1 232 0 13602511}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-cf(13602511)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-cf(13602511)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13602511
  • /ISO/Identified-Organization/6/1/4/1/232/0/13602511
  • /ISO/3/6/1/4/1/232/0/13602511
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-09-cf
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_9_cf
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-09-cf
  • Additional combinations skipped.

Descriptions

sCellEventTrap_9_cf — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.

sCellEventTrap-09-cf — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state.

Source records

sCellEventTrap_9_cf

Status in source: unspecified.

Names: sCellEventTrap_9_cf

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_9_cf",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.\"",
    "::=",
    "13602511"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_9_cf TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602511
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_9_cf.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_9_cf TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602511
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_9_cf.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-09-cf

Status in source: unspecified.

Names: sCellEventTrap-09-cf

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-cf",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state.\"",
    "::=",
    "13602511"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-09-cf TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602511
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-09-cf.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-09-cf TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602511
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-09-cf.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-09-cf TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state."
               --#TYPE      "StorageCell Event 09cf4105"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602511
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-09-cf.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-09-cf TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive has transitioned to the NOT PRESENT state."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13602511
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-09-cf.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136032001 mngmtAgentTrap-3200100
1.3.6.1.4.1.232.0.136032002 mngmtAgentTrap-3200200
1.3.6.1.4.1.232.0.136033001 mngmtAgentTrap-3300100
1.3.6.1.4.1.232.0.136033002 mngmtAgentTrap-3300200
1.3.6.1.4.1.232.0.136033003 mngmtAgentTrap-3300300
1.3.6.1.4.1.232.0.136033004 mngmtAgentTrap-3300400
1.3.6.1.4.1.232.0.136035000 mngmtAgentTrap-3500000