OID reference

sCellEventTrap_9_d6

1.3.6.1.4.1.232.0.13602518

Description

Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13602518
Node names
  • sCellEventTrap_9_d6
  • sCellEventTrap-09-d6
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.232.0.13602518
URN notation
urn:oid:1.3.6.1.4.1.232.0.13602518
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 232 0 13602518}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-d6(13602518)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-d6(13602518)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13602518
  • /ISO/Identified-Organization/6/1/4/1/232/0/13602518
  • /ISO/3/6/1/4/1/232/0/13602518
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-09-d6
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_9_d6
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-09-d6
  • Additional combinations skipped.

Available source records contain 6 distinct definitions; some records may not include a definition.

Show 6 published definitions

sCellEventTrap-09-d6 · unspecified

sCellEventTrap-09-d6 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602518

sCellEventTrap-09-d6 · unspecified

sCellEventTrap-09-d6 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602518

sCellEventTrap-09-d6 · unspecified

sCellEventTrap-09-d6 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602518

sCellEventTrap-09-d6 · unspecified

sCellEventTrap-09-d6 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event 09d63705"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602518

sCellEventTrap-09-d6 · unspecified

sCellEventTrap-09-d6 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event 09d63705"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602518

sCellEventTrap_9_d6 · unspecified

sCellEventTrap_9_d6 TRAP-TYPE  -- CAC Code: 0
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors do not agree and the system temperature can not be accurately determined. The value.ul1 field contains the current temperature reported in celsius from I2C sensor 1, while the value.ul2 field contains the reading from I2C sensor 2."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  INFORMATIONAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602518

Meaning

Descriptions

5 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.

Sources for this description

CircitorHPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.

Sources for this description

MIBdepot

See 1 matching source record

Description 3

Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors do not agree and the system temperature can not be accurately determined. The value.ul1 field contains the current temperature reported in celsius from I2C sensor 1, while the value.ul2 field contains the reading from I2C sensor 2.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)MIBdepot

See 1 matching source record

Evidence

Source records

5 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Circitor, HPE networking MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

sCellEventTrap-09-d6 · unspecifiedCircitor, HPE networking MIB copies (LibreNMS/Observium Community)2 sources

Status in source: unspecified.

Names: sCellEventTrap-09-d6

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d6",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.\"",
    "::=",
    "13602518"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 2MIBdepot1 record · 1 source

Description 2

sCellEventTrap-09-d6 · unspecifiedMIBdepot1 source

Status in source: unspecified.

Names: sCellEventTrap-09-d6

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d6",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.\"",
    "::=",
    "13602518"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 3HPE networking MIB copies (LibreNMS/Observium Community)1 record · 5 sources

Description 3

sCellEventTrap-09-d6 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community)5 sources

Status in source: unspecified.

Names: sCellEventTrap-09-d6

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d6",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.\"",
    "::=",
    "13602518"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 4HPE networking MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

sCellEventTrap-09-d6 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: sCellEventTrap-09-d6

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d6",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined.\"",
    "::=",
    "13602518"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors do not agree and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 5HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot1 record · 2 sources

Description 5

sCellEventTrap_9_d6 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community), MIBdepot2 sources

Status in source: unspecified.

Names: sCellEventTrap_9_d6

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_9_d6",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors do not agree and the system temperature can not be accurately determined. The value.ul1 field contains the current temperature reported in celsius from I2C sensor 1, while the value.ul2 field contains the reading from I2C sensor 2.\"",
    "::=",
    "13602518"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors do not agree and the system temperature can not be accurately determined. The value.ul1 field contains the current temperature reported in celsius from I2C sensor 1, while the value.ul2 field contains the reading from I2C sensor 2."
    ],
    null
  ]
}

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13602430 sCellEventTrap-09-7e00
1.3.6.1.4.1.232.0.13602431 sCellEventTrap-09-7f00
1.3.6.1.4.1.232.0.13602432 sCellEventTrap-09-8000
1.3.6.1.4.1.232.0.13602433 sCellEventTrap-09-8100
1.3.6.1.4.1.232.0.13602434 sCellEventTrap-09-8200
1.3.6.1.4.1.232.0.13602435 sCellEventTrap-09-8300
1.3.6.1.4.1.232.0.13602504 sCellEventTrap_9_c8, sCellEventTrap-09-c800
1.3.6.1.4.1.232.0.13602505 sCellEventTrap_9_c9, sCellEventTrap-09-c900
1.3.6.1.4.1.232.0.13602506 sCellEventTrap_9_ca, sCellEventTrap-09-ca00
1.3.6.1.4.1.232.0.13602507 sCellEventTrap_9_cb, sCellEventTrap-09-cb00
1.3.6.1.4.1.232.0.13602508 sCellEventTrap_9_cc, sCellEventTrap-09-cc00
1.3.6.1.4.1.232.0.13602509 sCellEventTrap_9_cd, sCellEventTrap-09-cd00
1.3.6.1.4.1.232.0.13602510 sCellEventTrap_9_ce, sCellEventTrap-09-ce00
1.3.6.1.4.1.232.0.13602511 sCellEventTrap_9_cf, sCellEventTrap-09-cf00
1.3.6.1.4.1.232.0.13602512 sCellEventTrap_9_d0, sCellEventTrap-09-d000
1.3.6.1.4.1.232.0.13602513 sCellEventTrap_9_d1, sCellEventTrap-09-d100
1.3.6.1.4.1.232.0.13602514 sCellEventTrap_9_d2, sCellEventTrap-09-d200
1.3.6.1.4.1.232.0.13602515 sCellEventTrap_9_d3, sCellEventTrap-09-d300
1.3.6.1.4.1.232.0.13602516 sCellEventTrap_9_d4, sCellEventTrap-09-d400
1.3.6.1.4.1.232.0.13602517 sCellEventTrap_9_d5, sCellEventTrap-09-d500
1.3.6.1.4.1.232.0.13602519 sCellEventTrap_9_d7, sCellEventTrap-09-d700
1.3.6.1.4.1.232.0.13602520 sCellEventTrap-09-d800
1.3.6.1.4.1.232.0.13602521 sCellEventTrap-09-d900
1.3.6.1.4.1.232.0.13602522 sCellEventTrap-09-da00
1.3.6.1.4.1.232.0.13602523 sCellEventTrap-09-db00
1.3.6.1.4.1.232.0.13602524 sCellEventTrap-09-dc00
1.3.6.1.4.1.232.0.13602525 sCellEventTrap-09-dd00
1.3.6.1.4.1.232.0.13602526 sCellEventTrap-09-de00
1.3.6.1.4.1.232.0.13602531 sCellEventTrap-09-e300
1.3.6.1.4.1.232.0.13602532 sCellEventTrap-09-e400
1.3.6.1.4.1.232.0.13602533 sCellEventTrap-09-e500
1.3.6.1.4.1.232.0.13602535 sCellEventTrap-09-e700
1.3.6.1.4.1.232.0.13602536 sCellEventTrap-09-e800
1.3.6.1.4.1.232.0.13602537 sCellEventTrap-09-e900
1.3.6.1.4.1.232.0.13602538 sCellEventTrap-09-ea00
1.3.6.1.4.1.232.0.13602539 sCellEventTrap-09-eb00
1.3.6.1.4.1.232.0.13602540 sCellEventTrap-09-ec00
1.3.6.1.4.1.232.0.13602541 sCellEventTrap-09-ed00
1.3.6.1.4.1.232.0.13602542 sCellEventTrap-09-ee00
1.3.6.1.4.1.232.0.13602816 sCellEventTrap_b_0, sCellEventTrap-0b-0000
1.3.6.1.4.1.232.0.13602817 sCellEventTrap-0b-0100
1.3.6.1.4.1.232.0.13602818 sCellEventTrap-0b-0200
1.3.6.1.4.1.232.0.13602819 sCellEventTrap-0b-0300
1.3.6.1.4.1.232.0.13602820 sCellEventTrap-0b-0400
1.3.6.1.4.1.232.0.13602821 sCellEventTrap-0b-0500
1.3.6.1.4.1.232.0.13602822 sCellEventTrap-0b-0600
1.3.6.1.4.1.232.0.13602823 sCellEventTrap-0b-0700
1.3.6.1.4.1.232.0.13602825 sCellEventTrap-0b-0900
1.3.6.1.4.1.232.0.13602827 sCellEventTrap-0b-0b00
1.3.6.1.4.1.232.0.13602828 sCellEventTrap-0b-0c00