OID reference

sCellEventTrap_9_d7

1.3.6.1.4.1.232.0.13602519

Description

Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13602519
Node names
  • sCellEventTrap_9_d7
  • sCellEventTrap-09-d7
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.232.0.13602519
URN notation
urn:oid:1.3.6.1.4.1.232.0.13602519
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 232 0 13602519}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-09-d7(13602519)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-09-d7(13602519)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13602519
  • /ISO/Identified-Organization/6/1/4/1/232/0/13602519
  • /ISO/3/6/1/4/1/232/0/13602519
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-09-d7
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_9_d7
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-09-d7
  • Additional combinations skipped.

Available source records contain 6 distinct definitions; some records may not include a definition.

Show 6 published definitions

sCellEventTrap-09-d7 · unspecified

sCellEventTrap-09-d7 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602519

sCellEventTrap_9_d7 · unspecified

sCellEventTrap_9_d7 TRAP-TYPE  -- CAC Code: 0
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors can not be accessed and the system temperature can not be accurately determined. The value.ul1 field contains the status from the attempted I2C access."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  INFORMATIONAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602519

sCellEventTrap-09-d7 · unspecified

sCellEventTrap-09-d7 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602519

sCellEventTrap-09-d7 · unspecified

sCellEventTrap-09-d7 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event 09d73705"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602519

sCellEventTrap-09-d7 · unspecified

sCellEventTrap-09-d7 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602519

sCellEventTrap-09-d7 · unspecified

sCellEventTrap-09-d7 TRAP-TYPE  -- CAC Code: 37
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
           --#TYPE      "StorageCell Event 09d73705"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  MINOR
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13602519

Meaning

Descriptions

5 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.

Sources for this description

CircitorHPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors can not be accessed and the system temperature can not be accurately determined. The value.ul1 field contains the status from the attempted I2C access.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)MIBdepot

See 1 matching source record

Description 3

Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.

Sources for this description

MIBdepot

See 1 matching source record

Description 5

Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

5 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Circitor, HPE networking MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

sCellEventTrap-09-d7 · unspecifiedCircitor, HPE networking MIB copies (LibreNMS/Observium Community)2 sources

Status in source: unspecified.

Names: sCellEventTrap-09-d7

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d7",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.\"",
    "::=",
    "13602519"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An HSV210 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 2HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot1 record · 2 sources

Description 2

sCellEventTrap_9_d7 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community), MIBdepot2 sources

Status in source: unspecified.

Names: sCellEventTrap_9_d7

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_9_d7",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors can not be accessed and the system temperature can not be accurately determined. The value.ul1 field contains the status from the attempted I2C access.\"",
    "::=",
    "13602519"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors can not be accessed and the system temperature can not be accurately determined. The value.ul1 field contains the status from the attempted I2C access."
    ],
    null
  ]
}
Records for description 3HPE networking MIB copies (LibreNMS/Observium Community)1 record · 5 sources

Description 3

sCellEventTrap-09-d7 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community)5 sources

Status in source: unspecified.

Names: sCellEventTrap-09-d7

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d7",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.\"",
    "::=",
    "13602519"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 4MIBdepot1 record · 1 source

Description 4

sCellEventTrap-09-d7 · unspecifiedMIBdepot1 source

Status in source: unspecified.

Names: sCellEventTrap-09-d7

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d7",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.\"",
    "::=",
    "13602519"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An HSV300 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
    ],
    null
  ]
}
Records for description 5HPE networking MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

sCellEventTrap-09-d7 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: sCellEventTrap-09-d7

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-09-d7",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined.\"",
    "::=",
    "13602519"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An HSV200 controller has been powered off because the temperature sensors can not be accessed and the system temperature can not be accurately determined."
    ],
    null
  ]
}

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136032001 mngmtAgentTrap-3200100
1.3.6.1.4.1.232.0.136032002 mngmtAgentTrap-3200200
1.3.6.1.4.1.232.0.136033001 mngmtAgentTrap-3300100
1.3.6.1.4.1.232.0.136033002 mngmtAgentTrap-3300200
1.3.6.1.4.1.232.0.136033003 mngmtAgentTrap-3300300
1.3.6.1.4.1.232.0.136033004 mngmtAgentTrap-3300400
1.3.6.1.4.1.232.0.136035000 mngmtAgentTrap-3500000