Reference record for OID 1.3.6.1.4.1.232.0.13603330

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603330
Node names
  • sCellEventTrap_d_2
  • sCellEventTrap-0d-02
Numeric OID
1.3.6.1.4.1.232.0.13603330
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603330
ASN.1 notation

{1 3 6 1 4 1 232 0 13603330}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-02(13603330)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-02(13603330)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603330
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603330
  • /ISO/3/6/1/4/1/232/0/13603330
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-02
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_2
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-02
  • Additional combinations skipped.

Descriptions

sCellEventTrap_d_2 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-0d-02 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition.

Source records

sCellEventTrap_d_2

Status in source: unspecified.

Names: sCellEventTrap_d_2

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_2",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603330"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_2 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_2.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_2 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_2.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-0d-02

Status in source: unspecified.

Names: sCellEventTrap-0d-02

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-02",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition.\"",
    "::=",
    "13603330"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-02.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-0d-02.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event 0d024111"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event 0d024106"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event 0d024106"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event 0d024106"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-0d-02 TRAP-TYPE  -- CAC Code: 41
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition."
               --#TYPE      "StorageCell Event 0d024106"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603330
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-0d-02.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136010039 mngmtAgentTrap_10039, mngmtAgentTrap-1003900
1.3.6.1.4.1.232.0.136010040 mngmtAgentTrap_10040, mngmtAgentTrap-1004000
1.3.6.1.4.1.232.0.136010041 mngmtAgentTrap_10041, mngmtAgentTrap-1004100
1.3.6.1.4.1.232.0.136010042 mngmtAgentTrap_10042, mngmtAgentTrap-1004200
1.3.6.1.4.1.232.0.136010043 mngmtAgentTrap_10043, mngmtAgentTrap-1004300
1.3.6.1.4.1.232.0.136010044 mngmtAgentTrap_10044, mngmtAgentTrap-1004400
1.3.6.1.4.1.232.0.136010047 mngmtAgentTrap-1004700
1.3.6.1.4.1.232.0.136010048 mngmtAgentTrap-1004800
1.3.6.1.4.1.232.0.136010049 mngmtAgentTrap-1004900
1.3.6.1.4.1.232.0.136010050 mngmtAgentTrap-1005000
1.3.6.1.4.1.232.0.136010051 mngmtAgentTrap-1005100
1.3.6.1.4.1.232.0.136010052 mngmtAgentTrap-1005200
1.3.6.1.4.1.232.0.136010053 mngmtAgentTrap-1005300
1.3.6.1.4.1.232.0.136010054 mngmtAgentTrap-1005400
1.3.6.1.4.1.232.0.136010055 mngmtAgentTrap-1005500
1.3.6.1.4.1.232.0.136010056 mngmtAgentTrap-1005600
1.3.6.1.4.1.232.0.136010057 mngmtAgentTrap-1005700
1.3.6.1.4.1.232.0.136010058 mngmtAgentTrap-1005800
1.3.6.1.4.1.232.0.136010059 mngmtAgentTrap-1005900
1.3.6.1.4.1.232.0.136010060 mngmtAgentTrap-1006000
1.3.6.1.4.1.232.0.136010061 mngmtAgentTrap-1006100
1.3.6.1.4.1.232.0.136010062 mngmtAgentTrap-1006200
1.3.6.1.4.1.232.0.136010063 mngmtAgentTrap-1006300
1.3.6.1.4.1.232.0.136010064 mngmtAgentTrap-1006400
1.3.6.1.4.1.232.0.136010065 mngmtAgentTrap-1006500
1.3.6.1.4.1.232.0.136010066 mngmtAgentTrap-1006600
1.3.6.1.4.1.232.0.136010067 mngmtAgentTrap-1006700
1.3.6.1.4.1.232.0.136010068 mngmtAgentTrap-1006800
1.3.6.1.4.1.232.0.136010069 mngmtAgentTrap-1006900
1.3.6.1.4.1.232.0.136010070 mngmtAgentTrap-1007000
1.3.6.1.4.1.232.0.136010071 mngmtAgentTrap-1007100
1.3.6.1.4.1.232.0.136010072 mngmtAgentTrap-1007200
1.3.6.1.4.1.232.0.136010073 mngmtAgentTrap-1007300
1.3.6.1.4.1.232.0.136010074 mngmtAgentTrap-1007400
1.3.6.1.4.1.232.0.136010075 mngmtAgentTrap-1007500
1.3.6.1.4.1.232.0.136010076 mngmtAgentTrap-1007600
1.3.6.1.4.1.232.0.136010077 mngmtAgentTrap-1007700
1.3.6.1.4.1.232.0.136010078 mngmtAgentTrap-1007800
1.3.6.1.4.1.232.0.136010079 mngmtAgentTrap-1007900
1.3.6.1.4.1.232.0.136010080 mngmtAgentTrap-1008000
1.3.6.1.4.1.232.0.136010081 mngmtAgentTrap-1008100
1.3.6.1.4.1.232.0.136010082 mngmtAgentTrap-1008200
1.3.6.1.4.1.232.0.136010083 mngmtAgentTrap-1008300
1.3.6.1.4.1.232.0.136010084 mngmtAgentTrap-1008400
1.3.6.1.4.1.232.0.136010085 mngmtAgentTrap-1008500
1.3.6.1.4.1.232.0.136010086 mngmtAgentTrap-1008600
1.3.6.1.4.1.232.0.136010087 mngmtAgentTrap-1008700
1.3.6.1.4.1.232.0.136010088 mngmtAgentTrap-1008800
1.3.6.1.4.1.232.0.136010089 mngmtAgentTrap-1008900
1.3.6.1.4.1.232.0.136010093 mngmtAgentTrap-1009300