Reference record for OID 1.3.6.1.4.1.232.0.13603419

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603419
Node names
  • sCellEventTrap_d_5b
  • sCellEventTrap-0d-5b
Numeric OID
1.3.6.1.4.1.232.0.13603419
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603419
ASN.1 notation

{1 3 6 1 4 1 232 0 13603419}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603419
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603419
  • /ISO/3/6/1/4/1/232/0/13603419
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-5b
  • Additional combinations skipped.

Descriptions

sCellEventTrap-0d-5b — MIBdepot

Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules.

sCellEventTrap-0d-5b — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements.

sCellEventTrap-0d-5b — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.

sCellEventTrap_d_5b — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

Source records

sCellEventTrap-0d-5b

Status in source: unspecified.

Names: sCellEventTrap-0d-5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

sCellEventTrap-0d-5b

Status in source: unspecified.

Names: sCellEventTrap-0d-5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
               --#TYPE      "StorageCell Event 0d5b8611"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

sCellEventTrap-0d-5b

Status in source: unspecified.

Names: sCellEventTrap-0d-5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap_d_5b

Status in source: unspecified.

Names: sCellEventTrap_d_5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5b.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.9026 cpqSm2FwUpdateUploadFailed00
1.3.6.1.4.1.232.0.9027 cpqSm2SecurityStateChange00
1.3.6.1.4.1.232.0.9028 cpqSm2WDTimerReset00
1.3.6.1.4.1.232.0.9029 cpqSm2OverallSecStateAtRisk00
1.3.6.1.4.1.232.0.9030 cpqSm2OverallSecStatusChange00
1.3.6.1.4.1.232.0.10001 cpqMeRisingAlarm00
1.3.6.1.4.1.232.0.10002 cpqMeFallingAlarm00
1.3.6.1.4.1.232.0.10003 cpqMe2RisingAlarm00
1.3.6.1.4.1.232.0.10004 cpqMe2FallingAlarm00
1.3.6.1.4.1.232.0.10005 cpqMeRisingAlarmExtended00
1.3.6.1.4.1.232.0.10006 cpqMeFallingAlarmExtended00
1.3.6.1.4.1.232.0.10007 cpqMeCriticalRisingAlarmExtended00
1.3.6.1.4.1.232.0.10008 cpqMeCriticalFallingAlarmExtended00
1.3.6.1.4.1.232.0.11001 cpqHoGenericTrap00
1.3.6.1.4.1.232.0.11002 cpqHoAppErrorTrap00
1.3.6.1.4.1.232.0.11003 cpqHo2GenericTrap00
1.3.6.1.4.1.232.0.11004 cpqHo2AppErrorTrap00
1.3.6.1.4.1.232.0.11005 cpqHo2NicStatusOk00
1.3.6.1.4.1.232.0.11006 cpqHo2NicStatusFailed00
1.3.6.1.4.1.232.0.11007 cpqHo2NicSwitchoverOccurred00
1.3.6.1.4.1.232.0.11008 cpqHo2NicStatusOk200
1.3.6.1.4.1.232.0.11009 cpqHo2NicStatusFailed200
1.3.6.1.4.1.232.0.11010 cpqHo2NicSwitchoverOccurred200
1.3.6.1.4.1.232.0.11011 cpqHoProcessEventTrap00
1.3.6.1.4.1.232.0.11012 cpqHoProcessCountWarning00
1.3.6.1.4.1.232.0.11013 cpqHoProcessCountNormal00
1.3.6.1.4.1.232.0.11014 cpqHoCriticalSoftwareUpdateTrap00
1.3.6.1.4.1.232.0.11015 cpqHoCrashDumpNotEnabledTrap00
1.3.6.1.4.1.232.0.11016 cpqHoBootPagingFileTooSmallTrap00
1.3.6.1.4.1.232.0.11017 cpqHoSWRunningStatusChangeTrap00
1.3.6.1.4.1.232.0.11018 cpqHo2PowerThresholdTrap00
1.3.6.1.4.1.232.0.11019 cpqHoBootPagingFileOrFreeSpaceTooSmallTrap00
1.3.6.1.4.1.232.0.11020 cpqHoMibHealthStatusArrayChangeTrap00
1.3.6.1.4.1.232.0.12001 cpqUpsLineFailed00
1.3.6.1.4.1.232.0.12002 cpqUpsLineOk00
1.3.6.1.4.1.232.0.12003 cpqUpsShutdown00
1.3.6.1.4.1.232.0.12004 cpqUpsConfirmation00
1.3.6.1.4.1.232.0.12005 cpqUpsBatteryLow00
1.3.6.1.4.1.232.0.12006 cpqUps2LineFailed00
1.3.6.1.4.1.232.0.12007 cpqUps2LineOk00
1.3.6.1.4.1.232.0.12008 cpqUps2Shutdown00
1.3.6.1.4.1.232.0.12009 cpqUps2Confirmation00
1.3.6.1.4.1.232.0.12010 cpqUps2BatteryLow00
1.3.6.1.4.1.232.0.12011 cpqUpsOverload00
1.3.6.1.4.1.232.0.12012 cpqUpsPendingBatteryFailure00
1.3.6.1.4.1.232.0.12013 cpqUpsGenericCritical00
1.3.6.1.4.1.232.0.12014 cpqUpsGenericInfo00
1.3.6.1.4.1.232.0.13001 cpqRsPartnerFailed00
1.3.6.1.4.1.232.0.13002 cpqRsStandbyCableFailure00
1.3.6.1.4.1.232.0.13003 cpqRsStandbyFailure00